Eaton xEffect FRCdM Residual Current Circuit Breaker (RCCB) — Type Bfq, 4-Pole, 40 A, 300 mA, Short-Time Delayed (167905)
Eaton

Eaton xEffect FRCdM Residual Current Circuit Breaker (RCCB) — Type Bfq, 4-Pole, 40 A, 300 mA, Short-Time Delayed

Part number167905EAN / GTIN4015081644803HS code8536.90
MOQ:1

Pricing

Request a quote

We reply within 24 hours

Product Description

The Eaton 167905 is a residual current circuit breaker (RCCB) from the Moeller series xEffect FRCdM range. It disconnects the circuit when the current flowing out does not match the current returning — the signature of a fault to earth, whether through failed insulation or through a person. It provides no overcurrent protection of its own and is installed together with the circuit's MCB or fuse. This device is 4-pole, rated 40 A, with a rated residual current of 300 mA. Type Bfq is Eaton's type B variant with a tripping curve adapted to reliably sense residual currents up to 50 kHz. It is the frequency-converter type, for installations whose normal operating leakage is itself high-frequency and would otherwise cause nuisance tripping or, worse, mask a real fault. Bfq and B+ are not interchangeable: B+ is chosen for fire protection, Bfq for drive-heavy installations. It is the G (short-time delayed) version, which rides through the brief leakage surges that switching and cable capacitance produce at energisation instead of tripping on them. At 300 mA it is intended for protection against earth-fault fire and for equipment protection, not for protection against direct contact — that requires a 30 mA device. Supplied by cBallast on quote-to-invoice terms; lead time and freight are quoted per RFQ against the destination Incoterm.

Technical Specifications

Manufacturer part number (MPN)
167905
EAN / GTIN
4015081644803
HS code
8536.90
Sales unit
pcs
Package quantity
30 pcs
Eaton catalogue number
167905
Depth
76 mm
Height
80 mm
Width
70 mm
Weight
0.32 kg
Compliances
RoHS conform
Certifications
IEC/EN 61008; IEC/EN 62423; EN45545-2; IEC 61373; ÖVE E 8601
Features
Residual current circuit-breakers, digital; Additional equipment possible; Selective protection
Fitted with
Interlocking device
Functions
Short-time delayed tripping
Special features
FRCdM Residual current circuit-breakers, digital Type G/Bfq (ÖVE E 8601)
Used with
Residual current circuit-breakers, digital; Type G/Bfq (�VE E 8601); FRCdM
Amperage Rating
40 A
Application
xEffect - Switchgear for industrial and advanced commercial applications
Fault current rating
300 mA
Impulse withstand current
3 kA (8/20 μs) surge-proof
Number of poles
Four-pole
Rated short-circuit strength
10 kA
Sensitivity type
All current sensitive - frequency converter-proof
Tripping time
10 ms delayed; Short time-delayed
Ambient operating temperature - max
50 °C
Ambient operating temperature - min
-25 °C
Equipment heat dissipation, current-dependent
6.2 W
Heat dissipation capacity
6.2 W
Heat dissipation per pole, current-dependent
1.55 W
Rated operational current for specified heat dissipation (In)
40 A
Static heat dissipation, non-current-dependent
0 W
Admissible back-up fuse
63 A gG/gL
Admissible back-up fuse overload - max
40 A gG/gL
Frequency rating
50 Hz
Leakage current type
B
Lifespan, electrical
4000 operations
Pollution degree
2
Radiation resistance
Suitable for variable frequency drives (enhanced sensitivity)
Rated fault current - max
0.3 A
Rated fault current - min
0.3 A
Rated impulse withstand voltage (Uimp)
4 kV
Rated insulation voltage (Ui)
440 V
Rated operational voltage (Ue) - max
415 V
Rated residual making and breaking capacity
500 A
Rated short-time withstand current (Icw)
10 kA
Short-circuit rating
63 A (max. admissible back-up fuse)
Surge current capacity
3 kA
Test circuit range
196 V AC - 456 V AC
Voltage rating - max
456 VAC
Voltage rating - min
50 VAC
Voltage rating (IEC/EN 60947-2)
240 V AC / 415 V AC
Switching capacity of auxiliary contact - min
10 μA, 10 mV DC
Switching current of auxiliary contact - max
2 A
Switching duty with resistive load of auxiliary contact - max
60 W
Switching voltage at AC of auxiliary contact - max
240 V
Switching voltage at DC of auxiliary contact - max
220 V
Terminal capacity of auxiliary contact
0.25 mm² - 1.5 mm²
Built-in depth
70.5 mm
Built-in width (number of units)
70 mm (4 SU)
Busbar material thickness
0.8 mm - 2 mm
Climatic proofing
25-55 °C / 90-95% relative humidity according to IEC 60068-2
Connectable conductor cross section (multi-wired) - max
16 mm²
Connectable conductor cross section (multi-wired) - min
1.5 mm²
Connectable conductor cross section (solid-core) - max
35 mm²
Connectable conductor cross section (solid-core) - min
1.5 mm²
Contact position indicator color
Red / green
Degree of protection
IP20; IP20, IP40 with suitable enclosure
Frame
45 mm
Lifespan, mechanical
20000 operations
Mounting Method
DIN rail; Quick attachment with 2 latch positions for DIN-rail IEC/EN 60715
Mounting position
As required
Permitted storage and transport temperature - max
60 °C
Permitted storage and transport temperature - min
-35 °C
Status indication
White / blue
Terminal capacity (cable)
M5 (with cross-recessed screw as defined in EN ISO 4757-Z2, PZ2)
Terminal capacity (solid wire)
1.5 mm² - 35 mm²
Terminal capacity (stranded cable)
16 mm² (2x)
Terminal protection
Finger and hand touch safe, DGUV VS3, EN 50274
Terminals (top and bottom)
Twin-purpose terminals
Tightening torque
2 Nm - 2.4 Nm
Width in number of modular spacings
4
Product family
Eaton Moeller series xEffect FRCdM RCCB
Device type
Residual current circuit breaker (RCCB), no integral overcurrent protection
Residual current type
Type Bfq
Rated residual current (IΔn)
300 mA
Rated current
40 A
Tripping characteristic
Short-Time Delayed (G)
Selection note
Frequency-converter variant — reliable sensing up to 50 kHz
Protection purpose
Protection against earth-fault fire / equipment protection

Standards & Compliance

HS Code
8536.90

Cross References

  • EAN 4015081644803
  • SAP 1000700530
  • Code 8416635
  • MPN 167905
  • Type Bfq

Catalogue entry last verified: 2026-09-29. A manufacturer datasheet is attached to this entry — confirm application-critical values against it.

Frequently asked questions

Where can I buy 167905?
167905 can be ordered from cballast.com as a Eaton catalogue item: request a quotation on this page or email sales@cballast.com, and the order ships worldwide.
What is the manufacturer part number for this Eaton product?
The manufacturer part number is 167905.
What is the HS code for 167905?
The customs tariff (HS) code for 167905 is 8536.90.
Who manufactures 167905?
167905 is a Eaton product in the Electrical Components range.
Is a datasheet available for 167905?
Yes — the 167905 datasheet can be viewed and downloaded on this page.
What is the minimum order quantity for 167905?
The minimum order quantity is 1.
Is 167905 available?
Yes — 167905 is available to order: fulfilment is from supplier stock in cBallast's European network, dispatched directly from the warehouse to the customer, with the exact lead time stated in the quotation (reply within 24 hours).