Product Description
Connect the t3000 FC Wireless Temperature Module to your test point, and view the results up to 20 meters away on the 3000 FC Wireless digital Multimeter.
Technical Specifications
- Manufacturer part number (MPN)
- 4465652 Brand: Fluke Category: Tools Range 1 Resolution: Accuracy 2 3 4 Range 1 45 Hz to 500 Hz: 500 Hz to 1 kHz 600.0 mV 0.1 mV: 1.0% + 3 6.000 V: 0.001 V 1000 V: 1 V Function Range: Resolution mV 600.0 mV: 0.1 mV V 6.000 V: 0.001 V 1000 V 1 V: 0.15% + 2 Ω 600 Ω: 1 Ω Ω 600.0 Ω: 0.1 Ω 6.000 kΩ 0.001 kΩ: 0.5% + 1 60.00 kΩ: 0.01 kΩ 50.00 MΩ 0.01 MΩ: 1.5% + 3 Diode test 2.000 V: 0.001 V µF 1000 nF: 1 nF µF 10.00 μF: 0.01 μF 9999 μF1 1 μF: 10% typical Function Range 1: Resolution mA AC (45 Hz to 1 kHz) 60.00 mA: 0.01 mA mA AC (45 Hz to 1 kHz) 400.0 mA 3: 0.1 mA mA DC 2 60.00 mA: 0.01 mA mA DC 2 400.0 mA 3: 0.1 mA Range Resolution: Accuracy 1 99.99 Hz 0.01 Hz: 0.1% + 1 999.9 Hz: 0.1 Hz 9.999 kHz: 0.001 kHz Function Overload protection: Input impedance (nominal) 1100 Vrms: > 10 MΩ < 100 pF Open circuit test voltage Full scale voltage: Typical short circuit current Open circuit test voltage To 6 MΩ: 50 MΩ Overload Protection: Fused, 44/100 A, 1000 V FAST Fuse Overload: 600 mA overload for 2 minutes maximum, 10 minutes rest minimum DC functions: The specified accuracy of the measurement function ± 12 counts for changes > 350 mS in duration. AC functions: The specified accuracy of the measurement function ± 40 counts for changes > 900 mS in duration. Maximum voltage between any terminal and earth ground: 1000 VDC or AC rms Ω fuse protection from A inputs: 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only Display (LCD) Update rate: 4/sec Display (LCD) Volts, amps, ohms: 6000 counts Display (LCD) Frequency: 10,000 counts Display (LCD) Capacitance: 1,000 counts Battery type: Three AA Alkaline batteries, NEDA 15A IEC LR6 Battery life: 250 hours minimum RF communications: 2.4 GHZ ISM Band RF communication range Open air, unobstructed: Up to 20 m RF communication range Obstructed, sheetrock wall: Up to 6.5 m Obstructed, concrete wall, or steel electrical enclosure: Up to 3.5 m Temperature Operating: -10°C to 50°C Temperature Storage: -40°C to 60°C Temperature coefficient: 0.1 x (specified accuracy) / °C ( 28°C) Relative humidity: 0% to 90% (0°C to 35°C) 0% to 75% (35°C to 40°C) 0% to 45% (40°C to 50°C) Altitude Operating: 2,000 m Altitude Storage: 12,000 m Electromagnetic compatibility EMI, RFI, EMC, RF: EN 61326-1:2006, EN 61326-2-2:2006 ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489 V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249 FCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLE Safety compliance ANSI/ISA 61010-1 / (82.02.01): 3rd edition Safety compliance CAN/CSA-C22.2 No 61010-1-12: 3rd edition Safety compliance UL 61010-1: 3rd edition Safety compliance IEC/EN 61010-1: 2010 Certifications: CSA, FCC, CE Ingress Protection (IP) rating: IP54 Pollution degree: 2 Size (H x W x L): 4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14 in) Weight: 340 g (12 oz) Warranty: Three years Range K-Type: -200°C to 1372°C Resolution: 0.1°C Accuracy: ±[0.5% + 0.5°C] counts Input terminals: K-type mini LCD w/backlight: 3 ½ digits Log rate/interval: 1 sec minimum/adjustable by PC Memory: Record up to 65,000 readings Operating temperature: -10°C to +50°C Storage temperature: -40°C to +60°C Temperature scale: ITS-90 Operating humidity: 90% at 35°C, 75% at 40°C, 45% at 50°C EMC: EN 61326-1:2006 Safety compliance: IEC 61010-1, CAT I, 3rd edition Pollution Degree 2 Size (H x W x D): 16.5 x 6.35 x 1.4 cm (6.5 x 2.5 x 1.4 in)
Cross References
- OEM-URL https://www.fluke.com/en-us/product/temperature-measurement/contact-thermometers/fluke-t3000-fc-kit
Product Documentation
Document preview: 3000 FC | Users manual
More from Fluke

Fluke
P5523 Liquid to Gas Media Separator
FLUKE-CALIBRATION-P5523

Fluke
Fluke Calibration 1524 Handheld Thermometer Readout
3376600

Fluke
Fluke 3130-G2M Portable Pressure Calibrator
4317885

Fluke
P5543 Angle Adapter
3875955

Fluke
Fluke 719PRO Electric Pressure Calibrator
4353218

Fluke
Fluke 750P Series Pressure Modules
4352270

Fluke
P5551 Pointer Remover/Punch
3885659

Fluke
Fluke 700PRV-1 Pressure Relief Valve Kit
2811808
Catalogue entry last verified: 2026-08-30. A manufacturer datasheet is attached to this entry — confirm application-critical values against it.
Frequently asked questions
- Where can I buy 4465652?
- 4465652 can be ordered from cballast.com as a Fluke catalogue item: request a quotation on this page or email sales@cballast.com, and the order ships worldwide.
- What is the manufacturer part number for this Fluke product?
- The manufacturer part number is 4465652.
- Who manufactures 4465652?
- 4465652 is a Fluke product in the Safety & Detection range.
- Is a datasheet available for 4465652?
- Yes — the 4465652 datasheet can be viewed and downloaded on this page.
- What is the minimum order quantity for 4465652?
- The minimum order quantity is 1.
- Is 4465652 available?
- Yes — 4465652 is available to order: fulfilment is from supplier stock in cBallast's European network, dispatched directly from the warehouse to the customer, with the exact lead time stated in the quotation (reply within 24 hours).
- How do I get a price for 4465652?
- Request a quotation with the quote button on this page or by email to sales@cballast.com — we reply within 24 hours with price, availability and lead time.