Fluke T3000 FC Wireless Temperature Kit

Fluke · Safety & Detection · Tools · USA · fluke.com
Part Number
4465652
Fluke T3000 FC Wireless Temperature Kit

Connect the t3000 FC Wireless Temperature Module to your test point, and view the results up to 20 meters away on the 3000 FC Wireless digital Multimeter.

Technical Specifications

Manufacturer part number (MPN)4465652 Brand: Fluke Category: Tools Range 1 Resolution: Accuracy 2 3 4 Range 1 45 Hz to 500 Hz: 500 Hz to 1 kHz 600.0 mV 0.1 mV: 1.0% + 3 6.000 V: 0.001 V 1000 V: 1 V Function Range: Resolution mV 600.0 mV: 0.1 mV V 6.000 V: 0.001 V 1000 V 1 V: 0.15% + 2 Ω 600 Ω: 1 Ω Ω 600.0 Ω: 0.1 Ω 6.000 kΩ 0.001 kΩ: 0.5% + 1 60.00 kΩ: 0.01 kΩ 50.00 MΩ 0.01 MΩ: 1.5% + 3 Diode test 2.000 V: 0.001 V µF 1000 nF: 1 nF µF 10.00 μF: 0.01 μF 9999 μF1 1 μF: 10% typical Function Range 1: Resolution mA AC (45 Hz to 1 kHz) 60.00 mA: 0.01 mA mA AC (45 Hz to 1 kHz) 400.0 mA 3: 0.1 mA mA DC 2 60.00 mA: 0.01 mA mA DC 2 400.0 mA 3: 0.1 mA Range Resolution: Accuracy 1 99.99 Hz 0.01 Hz: 0.1% + 1 999.9 Hz: 0.1 Hz 9.999 kHz: 0.001 kHz Function Overload protection: Input impedance (nominal) 1100 Vrms: > 10 MΩ < 100 pF Open circuit test voltage Full scale voltage: Typical short circuit current Open circuit test voltage To 6 MΩ: 50 MΩ Overload Protection: Fused, 44/100 A, 1000 V FAST Fuse Overload: 600 mA overload for 2 minutes maximum, 10 minutes rest minimum DC functions: The specified accuracy of the measurement function ± 12 counts for changes > 350 mS in duration
AC functionsThe specified accuracy of the measurement function ± 40 counts for changes > 900 mS in duration. Maximum voltage between any terminal and earth ground: 1000 VDC or AC rms Ω fuse protection from A inputs: 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only Display (LCD) Update rate: 4/sec Display (LCD) Volts, amps, ohms: 6000 counts Display (LCD) Frequency: 10,000 counts Display (LCD) Capacitance: 1,000 counts Battery type: Three AA Alkaline batteries
NEDA 15A IEC LR6 Battery life250 hours minimum RF communications: 2.4 GHZ ISM Band RF communication range Open air, unobstructed: Up to 20 m RF communication range Obstructed, sheetrock wall: Up to 6.5 m Obstructed, concrete wall, or steel electrical enclosure: Up to 3.5 m Temperature Operating: -10°C to 50°C Temperature Storage: -40°C to 60°C Temperature coefficient: 0.1 x (specified accuracy) / °C ( 28°C) Relative humidity: 0% to 90% (0°C to 35°C) 0% to 75% (35°C to 40°C) 0% to 45% (40°C to 50°C) Altitude Operating: 2,000 m Altitude Storage: 12,000 m Electromagnetic compatibility EMI, RFI, EMC
RFEN 61326-1:2006, EN 61326-2-2:2006 ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489 V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249 FCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLE Safety compliance ANSI/ISA 61010-1 / (82.02.01): 3rd edition Safety compliance CAN/CSA-C22.2 No 61010-1-12: 3rd edition Safety compliance UL 61010-1: 3rd edition Safety compliance IEC/EN 61010-1: 2010 Certifications: CSA, FCC
CE Ingress Protection (IP) ratingIP54 Pollution degree: 2 Size (H x W x L): 4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14 in) Weight: 340 g (12 oz) Warranty: Three years Range K-Type: -200°C to 1372°C Resolution: 0.1°C Accuracy: ±[0.5% + 0.5°C] counts Input terminals: K-type mini LCD w/backlight: 3 ½ digits Log rate/interval: 1 sec minimum/adjustable by PC Memory: Record up to 65,000 readings Operating temperature: -10°C to +50°C Storage temperature: -40°C to +60°C Temperature scale: ITS-90 Operating humidity: 90% at 35°C, 75% at 40°C, 45% at 50°C EMC: EN 61326-1:2006 Safety compliance: IEC 61010-1, CAT I, 3rd edition Pollution Degree 2 Size (H x W x D): 16.5 x 6.35 x 1.4 cm (6.5 x 2.5 x 1.4 in)

Properties

MOQ1

Cross-References

Attached Documents