Technical Specifications
- Manufacturer part number (MPN)
- 5132939
- Brand
- Fluke
- Category
- Tools
- Range
- 999.9 A
- Resolution
- 0.1 A
- Accuracy
- 2% ±5 digits (10 Hz to 100 Hz)
- Crest Factor (50 Hz/60 Hz)
- 3 @ 500 A
- Crest Factor (50/60Hz)
- 3.0 at 1100 A
- i2500-10 Flex
- i2500-18 Flex
- Distance from Optimum 0.5 in (12.7 mm)
- 1.4 in (35.6 mm)
- Distance from Optimum 0.8 in (20.3 mm)
- 2.0 in (50.8 mm)
- Distance from Optimum 1.4 in (35.6 mm)
- 2.5 in (63.5 mm)
- Trigger level
- 5 Hz to 10 Hz, ≥10 A
- Maximum voltage between any terminal and earth ground
- 1000 V
- Batteries
- 2 AA, NEDA 15A, IEC LR6
- Operating temperature
- -10 °C to +50 °C
- Storage temperature
- -40 °C to +60 °C
- Operating humidity - non-condensing (< 10°C)
- ≤90% RH (at 10 °C to 30 °C)
- Operating altitude
- 2000 m
- Storage altitude
- 12,000 m
- Size (L x W x H)
- 249 x 85 x 45 mm
- Weight
- 395 g
- Jaw opening
- 34 mm
- Flexible current probe diameter
- 7.5 mm
- Safety
- IEC 61010-1, Pollution Degree 2
- IP rating
- IEC 60529: IP30, non-operating
- Radio Frequency Certification FCC ID
- T68-FBLE IC:6627A-FBLE
- International
- IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2
- Korea (KCC)
- Class A Equipment (Industrial Broadcasting & Communication Equipment)
- USA (FCC)
- 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
- Temperature coefficients
- Add 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C
- Voltage DC Maximum voltage
- 1000 V
- Voltage DC Accuracy
- ±(0.05% + 1)
- Voltage DC Maximum resolution
- 10 µV
- Voltage AC Maximum voltage
- 1000 V
- Voltage AC Accuracy
- ±(0.7% + 2) True RMS
- Voltage AC AC bandwidth
- 20 kHz with low pass filter; 3 db @ 1 kHz
- Voltage AC Maximum resolution
- 0.1 mV
- Current DC Maximum amps
- 10 A (20 A for 30 seconds maximum)
- Current DC Amps accuracy
- ±(0.2% + 2)
- Current DC Maximum resolution
- 0.01 µA
- Current AC Maximum amps
- 10 A (20 A for 30 seconds maximum)
- Current AC Amps accuracy
- ±(1.0% + 2) True RMS
- Current AC Maximum resolution
- 0.1 µA
- Resistance Maximum resistance
- 50 MΩ
- Resistance Accuracy
- ±(0.2% + 1)
- Resistance Maximum resolution
- 0.1 Ω
- Capacitance Maximum capacitance
- 9,999 µF
- Capacitance Accuracy
- ±(1% + 2)
- Capacitance Maximum resolution
- 0.01 nF
- Frequency Maximum frequency
- 200 kHz
- Frequency Accuracy
- ±(0.005% + 1)
- Frequency Maximum resolution
- 0.01 Hz
- Duty cycle Maximum duty cycle
- 99.9%
- Duty cycle Accuracy
- ±(0.2% per khz + 0.1%)
- Duty cycle Maximum resolution
- 0.1%
- Temperature
- –200.0 °C – 1090 °C
- 80 BK
- –40.0 °C – 260 °C
- Conductance Maximum conductance
- 60.00 nS
- Conductance Accuracy
- ±(1.0% + 10)
- Conductance Maximum resolution
- 0.01 nS
- Diode Range
- 3 V
- Diode Resolution
- 1 mV
- Diode Accuracy
- ±(2% + 1)
- Duty cycle range Accuracy
- Within ±(0.2% per kHz + 0.1%)
- Operating
- –20 °C to + 55 °C
- Storage
- –40 °C to + 60 °C
- Humidity
- 0% – 90% (0 °C – 35 °C)
- Overvoltage
- EN 61010–1 to 1000 V CAT III, 600V CAT IV
- Agency
- UL, CSA, TÜV, VDE listed
- Size
- 201 x 98 x 52 mm (with holster)
- Display Digital
- 6000 counts updates 4/sec.
- Display Analog
- 32 segments, updates 40/sec
- Display Frequency
- 19,999 counts, updates 3/sec at > 10 Hz
- Warranty
- Lifetime
- Battery Life Alkaline
- ~400 hours typical, without backlight
- Shock
- 1 Meter drop per IEC 61010–1:2001
- Vibration
- Per MIL–PRF–28800 for a Class 2 instrument
Standards & Compliance
- HS Code
- 9030.33
Cross References
- OEM-URL https://www.fluke.com/en-us/product/electrical-testing/insulated-tools/376-clamp-meter-hand-tools-kit
More from Fluke

Fluke
Solar Tools Kit with 87V Max Digital Multimeter and Test Leads
5337412

Fluke
Fluke 283 FC/PV Solar Kit with TLPV1 and TLPV2 Test Leads
6162770

Fluke
Fluke 117 Electrician's Multimeter with Non-Contact Voltage
2538815

Fluke
Fluke 113 Digital Multimeter
3078875

Fluke
Fluke 365 Detachable Jaw True RMS AC/DC Clamp Meter
3620217

Fluke
59 MAX Infrared Thermometer
4393777

Fluke
Fluke TLPV1 MC4 to 4mm Test Lead Set
5590592

Fluke
Fluke T5-1000 Voltage, Continuity and Current Tester
648219
Catalogue entry last verified: 2026-10-03.
Frequently asked questions
- Where can I buy 5132939?
- 5132939 can be ordered from cballast.com as a Fluke catalogue item: request a quotation on this page or email sales@cballast.com, and the order ships worldwide.
- What is the manufacturer part number for this Fluke product?
- The manufacturer part number is 5132939.
- What is the HS code for 5132939?
- The customs tariff (HS) code for 5132939 is 9030.33.
- Who manufactures 5132939?
- 5132939 is a Fluke product in the Safety & Detection range.
- What is the minimum order quantity for 5132939?
- The minimum order quantity is 1.
- Is 5132939 available?
- Yes — 5132939 is available to order: fulfilment is from supplier stock in cBallast's European network, dispatched directly from the warehouse to the customer, with the exact lead time stated in the quotation (reply within 24 hours).
- How do I get a price for 5132939?
- Request a quotation with the quote button on this page or by email to sales@cballast.com — we reply within 24 hours with price, availability and lead time.