
Schneider Electric Circuit breaker, ComPacT NSX100HB1, 75KA/690VAC, 3 poles, MicroLogic 6.2E-M trip unit 50A C10V36M050
Pricing
Request a quote
We reply within 24 hours
Product Description
Schneider Electric C10V36M050 Circuit breaker ComPacT NSX100HB1 with motor protection and energy metering 6.2E-M 50A 3P 50A 75kA/690VAC.
Technical Specifications
- Manufacturer part number (MPN)
- C10V36M050
- EAN / GTIN
- 3606482002081
- HS code
- 8536.90
- Sales unit
- pcs
- Rated current
- 50 A
- Number of poles
- 3P
- Range
- ComPacT
- Product name
- ComPacT NSX
- Device short name
- NSX100HB1
- Product or component type
- Circuit breaker
- Device application
- Motor protection
- Poles description
- 3P
- Protected poles description
- 3D
- [In] rated current
- 50 A at 65 °C
- [Ue] rated operational voltage
- 690 V AC 50/60 Hz
- Network type
- AC
- Network frequency
- 50/60 Hz
- Suitability for isolation
- Yes conforming to EN/IEC 60947-2
- Utilisation category
- Category A
- Breaking capacity
- 85 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2; 80 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2; 75 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
- Breaking capacity code
- HB1 75 kA 690 V AC
- Trip unit name
- MicroLogic 6.2 E-M
- Trip unit technology
- Electronic
- Trip unit protection functions
- LSIG
- Control type
- Toggle
- Circuit breaker mounting mode
- Fixed
- [Ui] rated insulation voltage
- 800 V AC 50/60 Hz
- [Uimp] rated impulse withstand voltage
- 8 kV
- [Ics] rated service breaking capacity
- 85 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2; 80 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2; 75 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
- Mechanical durability
- 20000 cycles
- Electrical durability
- 20000 cycles at 440 V In/2; 10000 cycles at 440 V In; 10000 cycles at 690 V In/2; 5000 cycles at 690 V In
- Power dissipation per pole
- 4.7 W
- Mounting support
- Backplate
- Mounting position
- Horizontal and vertical; Flat on the back
- Upside connection
- Front
- Downside connection
- Front
- Connection pitch
- 35 mm
- Protection type
- L : for overload protection (long time); So : for short time short-circuit protection; I : for instantaneous short-circuit protection; G : for ground fault protection
- Trip unit rating
- 50 A at 65 °C
- Motor tripping class
- 10; 5; 20; 30
- Complementary motor protection
- Stalled rotor; Underload; Phase unbalance; Protracted starting time
- Long-time pick-up adjustment type Ir (thermal protection)
- Adjustable 9 settings
- [Ir] long-time protection pick-up adjustment range
- 25...50 A
- Long-time protection delay adjustment type tr
- Adjustable
- [tr] long-time delay adjustment range
- 120 s at 1.5 x Ir for trip class 5; 6.5 s at 6 x Ir for trip class 5; 5 s at 7.2 x Ir for trip class 5; 240 s at 1.5 x Ir for trip class 10; 13.5 s at 6 x Ir for trip class 10; 10 s at 7.2 x Ir for trip class 10; 480 s at 1.5 x Ir for trip class 20; 26 s at 6 x Ir for trip class 20; 20 s at 7.2 x Ir for trip class 20; 720 s at 1.5 x Ir for trip class 30; 38 s at 6 x Ir for trip class 30; 30 s at 7.2 x Ir for trip class 30
- Thermal memory
- 20 minutes before and after tripping
- Short-time protection pick-up adjustment type Isd
- Adjustable
- [Isd] Short-time protection pick-up adjustment range
- 5...13 x Ir
- Short-time protection delay adjustment type tsd
- Fixed
- Instantaneous protection pick-up adjustment type Ii
- Fixed
- [Ii] instantaneous protection pick-up adjustment range
- 750 A
- Ground-fault protection pick-up adjustment type Ig
- Adjustable 9 settings
- [Ig] ground-fault pick-up adjustment range
- 0.6...1 x In for In = 25 A; 0.3...1 x In for In = 50 A; 0.2...1 x In for In > 50 A; Ig enable on/off
- Ground-fault protection time delay adjustment type tg
- Adjustable 5 settings
- [tg] Ground-fault time delay adjustment range
- 0…0.4 s
- Earth-leakage protection
- Without
- Zone selective interlocking ZSI
- With
- Number of slots
- 5 slot(s)
- Local signalling
- Flashing LED (green) for ready to operate; LED 95 % Ith (red) for temperature over set point
- Display type
- LCD display
- Type of measurement
- Energy meter
- Communication of data
- Maximeters/minimeters; Protection and alarm settings; Demand current and power; Maintenance indicators; Power quality; Phase sequence; Time-stamped histories and event tables; Energy metering; Thermal image function; Instantaneous and demand values
- Width (W)
- 105 mm
- Height (H)
- 161 mm
- Depth (D)
- 86 mm
- Product weight
- 2.05 kg
- Standards
- EN/IEC 60947-2
- Overvoltage category
- III
- Electrical shock protection class
- Class II on front face
- Pollution degree
- 3 conforming to IEC 60664-1
- IP degree of protection
- IP40 conforming to IEC 60529
- IK degree of protection
- IK07 conforming to IEC 62262
- Ambient air temperature for operation
- -25…70 °C
- Ambient air temperature for storage
- -40…85 °C
- Relative humidity
- 0…95 %
- Operating altitude
- 0...2000 m without derating; 2000 m...5000 m with derating
- Warranty (in months)
- 18
Standards & Compliance
- HS Code
- 8536.90
Cross References
- EAN 3606482002081
- SAP 1200534499
- Code 82688636
Product Documentation
More from Schneider Electric

Schneider Electric
Schneider Electric Preventa XPE, Single foot switch, plastic, blue, without cover, 1 NO + 1 NC XPEB110

Schneider Electric
Schneider Electric D40A to D65A Diode 24-250VDC Suppressor LAD4D3U

Schneider Electric
LED lamp 8mm 24V Orange (XVLA135)

Schneider Electric
Controller (XD2CL1111)

Schneider Electric
Schneider Electric Harmony K1, K2, Cam switch, 3 poles, with off position, 45° switching angle, 20 A, multi-fixing K2C003ALH

Schneider Electric
Schneider Electric distributed analog output Modicon Momentum - 4 Output - 4..20 mA 170AAO92100

Schneider Electric
Schneider Electric Floor standing encl.polyester vers.PLAZT w/open plinth+canopy 1500X750X320 IP44 NSYPLAZT1573G

Schneider Electric
Emergency stop head square with LED 120V
ZB5AS84W2G
Technical guides
Catalogue entry last verified: 2026-09-29. A manufacturer datasheet is attached to this entry — confirm application-critical values against it.
Frequently asked questions
- Where can I buy C10V36M050?
- C10V36M050 can be ordered from cballast.com as a Schneider Electric catalogue item: request a quotation on this page or email sales@cballast.com, and the order ships worldwide.
- What is the manufacturer part number for this Schneider Electric product?
- The manufacturer part number is C10V36M050.
- What is the HS code for C10V36M050?
- The customs tariff (HS) code for C10V36M050 is 8536.90.
- Who manufactures C10V36M050?
- C10V36M050 is a Schneider Electric product in the Electrical Components range.
- Is a datasheet available for C10V36M050?
- Yes — the C10V36M050 datasheet can be viewed and downloaded on this page.
- What is the minimum order quantity for C10V36M050?
- The minimum order quantity is 1.
- Is C10V36M050 available?
- Yes — C10V36M050 is available to order: fulfilment is from supplier stock in cBallast's European network, dispatched directly from the warehouse to the customer, with the exact lead time stated in the quotation (reply within 24 hours).
