Schneider Electric Control relay, TeSys Deca, 5NO, <=690V, 24V DC standard coil, snap-in terminals CAD50ABD
Pricing
Request a quote
We reply within 24 hours
Product Description
Schneider Electric CAD50ABD Auxiliary contactor, TeSys Deca, 5NO, <=690V, 24V DC standard coil, Snap-In terminals.
Technical Specifications
- Manufacturer part number (MPN)
- CAD50ABD EAN / GTIN: 3606487541271 HS code: 8536.90 Sales unit: pcs Package quantity: 15 pcs Voltage: 24 V Number of poles: 3P Contact configuration: 5 NO + 0 NC Range: TeSys Product name: TeSys CAD Product or component type: Control relay Device short name: CAD Contactor application: Control circuit Utilisation category: AC-15; AC-14; DC-13 Pole contact composition: 5 NO [Ue] rated operational voltage: <= 690 V AC 25...400 Hz Control circuit type: DC standard [Uc] control circuit voltage: 24 V DC [Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 60947 [Ith] conventional free air thermal current: 10 A (at 60 °C) Irms rated making capacity: 140 A AC; 250 A DC [Icw] rated short-time withstand current: 100 A - 1 s; 120 A - 500 ms; 140 A - 100 ms Associated fuse rating: 10 A gG conforming to IEC 60947-5-1 [Ui] rated insulation voltage: 690 V conforming to IEC 60947-5-1 Mounting support: Rail; Plate Connections - terminals: Snap-in terminal 1 cable(s) 0.5…4 mm²flexible without cable end; Snap-in terminal 2 cable(s) 0.5…4 mm²flexible without cable end; Snap-in terminal 1 cable(s) 0.5…2.5 mm²flexible with cable end; Snap-in terminal 2 cable(s) 0.5…2.5 mm²flexible with cable end; Snap-in terminal 1 cable(s) 0.5…2.5 mm²solid without cable end; Snap-in terminal 2 cable(s) 0.5…2.5 mm²solid without cable end Control circuit voltage limits: 0.1...0.25 Uc (-40…70 °C):drop-out DC; 0.7...1.25 Uc (-40…60 °C):operational DC; 1...1.25 Uc (60…70 °C):operational DC Operating time: 53...72 ms coil energisation and NO closing; 16...24 ms coil de-energisation and NO opening Mechanical durability: 30 Mcycles Maximum operating rate: 180 cyc/mn Time constant: 28 ms Inrush power in W: 5.4 W (at 20 °C) Hold-in power consumption in W: 5.4 W at 20 °C minimum switching voltage: 17 V minimum switching current: 5 mA Non-overlap time: 1.5 ms on energisation between NC and NO contact; 1.5 ms on de-energisation between NC and NO contact Insulation resistance: > 10 MOhm Mechanical robustness: Shocks control relay open: 10 Gn for 11 ms conforming to IEC 60068-2-27; Shocks control relay closed: 15 Gn for 11 ms conforming to IEC 60068-2-27; Vibrations control relay open: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6; Vibrations control relay closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Height: 107 mm Width: 45 mm Depth: 93 mm Product weight: 562 g Standards: EN/IEC 60947-5-1; UL 60947-5-1; CSA C22.2 No 60947-5-1; GB/T 14048.5; JIS C8201-5-1 Product certifications: CB Scheme; CCC; cULus; CE; UKCA; EU-RO-MR by DNV IP degree of protection: IP2X front face conforming to VDE 0106 Protective treatment: TH conforming to IEC 60068 Ambient air temperature for operation: -40…60 °C; 60…70 °C with derating Ambient air temperature for storage: -60…80 °C Operating altitude: 0...3000 m Warranty (in months): 18
Standards & Compliance
- HS Code
- 8536.90
Cross References
- EAN 3606487541271
- SAP 1200879666
- Code 84149535
Product Documentation
More from Schneider Electric

Schneider Electric
Schneider Electric Circuit breaker, ComPacT NSX100HB2, 100KA/690VAC, 3 poles, MA trip unit 100A C10W3MA100

Schneider Electric
Schneider Electric Marker, Linergy TR cable ends, yellow, clipin type, character +, Symbolic, set of 200 AR1MA0198

Schneider Electric
Front plate NSX250VIGI Vertical PrismaSeT G/P
LVS03241

Schneider Electric
Schneider Electric Contactor, TeSys Deca, 3P(3NO), AC-3/3E, <=440V, 18A, 110V AC 50/60Hz coil, snap-in terminals LC1D18AF7

Schneider Electric
Schneider Electric Illuminated selector switch, Harmony XB4, metal, red handle, 22mm, universal LED, 2 positions, 1NO + 1NC, 230...240V AC XB4BK124M5

Schneider Electric
Schneider Electric Floor standing encl. polyester vers.PLAT open top w/ canopy 750X500X320 IP44 NSYPLAT753G

Schneider Electric
Schneider Electric APC NetShelter Rack PDU, Metered, 0U, 5.0kW 200V and 208V 30A, (36) C13 and (6) C19 outlets AP8841

Schneider Electric
Schneider Electric Slim interface relay pre-assembled, 6 A, 1 CO, LED, protection module, spring terminal, 110 V AC RSL1PVFU
Technical guides
Catalogue entry last verified: 2026-09-30. A manufacturer datasheet is attached to this entry — confirm application-critical values against it.
Frequently asked questions
- Where can I buy CAD50ABD?
- CAD50ABD can be ordered from cballast.com as a Schneider Electric catalogue item: request a quotation on this page or email sales@cballast.com, and the order ships worldwide.
- What is the manufacturer part number for this Schneider Electric product?
- The manufacturer part number is CAD50ABD.
- What is the HS code for CAD50ABD?
- The customs tariff (HS) code for CAD50ABD is 8536.90.
- Who manufactures CAD50ABD?
- CAD50ABD is a Schneider Electric product in the Control & Automation range.
- Is a datasheet available for CAD50ABD?
- Yes — the CAD50ABD datasheet can be viewed and downloaded on this page.
- What is the minimum order quantity for CAD50ABD?
- The minimum order quantity is 1.
- Is CAD50ABD available?
- Yes — CAD50ABD is available to order: fulfilment is from supplier stock in cBallast's European network, dispatched directly from the warehouse to the customer, with the exact lead time stated in the quotation (reply within 24 hours).