
Schneider Electric TeSys K contactor - 3P - AC-3 <= 440 V 9 A - 1 NO aux. - 24 V DC coil LP1K0910BD
Pricing
Request a quote
We reply within 24 hours
Product Description
Schneider Electric LP1K0910BD Contactor 9A 3P+1NO 24VDC.
Technical Specifications
- Manufacturer part number (MPN)
- LP1K0910BD EAN / GTIN: 3389110363241 HS code: 8536.90 Sales unit: pcs Package quantity: 40 pcs Number of poles: 3 Range: TeSys Product or component type: Contactor Device short name: LP1K Contactor application: Motor control; Resistive load Utilisation category: AC-3; AC-3e; AC-1; AC-4 Poles description: 3P power pole contact composition: 3 NO [Ue] rated operational voltage: Power circuit: <= 690 V AC <= 400 Hz; Signalling circuit: <= 690 V AC <= 400 Hz [Ie] rated operational current: 9 A (at <60 °C) at <= 440 V AC AC-3 for power circuit; 9 A (at <60 °C) at <= 440 V AC AC-3e for power circuit; 20 A (at <60 °C) at <= 690 V AC AC-1 for power circuit Control circuit type: DC standard [Uc] control circuit voltage: 24 V DC Motor power kW: 2.2 kW at 220...230 V AC 50/60 Hz AC-3; 4 kW at 380...415 V AC 50/60 Hz AC-3; 4 kW at 440/690 V AC 50/60 Hz AC-3; 2.2 kW at 220...230 V AC 50/60 Hz AC-3e; 4 kW at 380...415 V AC 50/60 Hz AC-3e; 4 kW at 440/690 V AC 50/60 Hz AC-3e; 2.2 kW at 220...230 V AC 50/60 Hz AC-4; 4 kW at 380...415 V AC 50/60 Hz AC-4; 4 kW at 440/690 V AC 50/60 Hz AC-4 Auxiliary contact composition: 1 NO [Uimp] rated impulse withstand voltage: 8 kV Overvoltage category: III [Ith] conventional free air thermal current: 20 A (at 60 °C) for power circuit; 10 A (at 50 °C) for signalling circuit Irms rated making capacity: 110 A AC for power circuit conforming to IEC 60947; 110 A AC for signalling circuit conforming to IEC 60947 Rated breaking capacity: 110 A at 220...230 V conforming to IEC 60947; 110 A at 380...400 V conforming to IEC 60947; 110 A at 415 V conforming to IEC 60947; 110 A at 440 V conforming to IEC 60947; 80 A at 500 V conforming to IEC 60947; 70 A at 660...690 V conforming to IEC 60947 [Icw] rated short-time withstand current: 90 A 50 °C - 1 s for power circuit; 85 A 50 °C - 5 s for power circuit; 80 A 50 °C - 10 s for power circuit; 60 A 50 °C - 30 s for power circuit; 45 A 50 °C - 1 min for power circuit; 40 A 50 °C - 3 min for power circuit; 20 A 50 °C - >= 15 min for power circuit; 80 A - 1 s for signalling circuit; 90 A - 500 ms for signalling circuit; 110 A - 100 ms for signalling circuit Associated fuse rating: 25 A gG at <= 440 V for power circuit; 25 A aM for power circuit; 10 A gG for signalling circuit conforming to IEC 60947; 10 A gG for signalling circuit conforming to VDE 0660 Average impedance: 3 mOhm - Ith 20 A 50 Hz for power circuit [Ui] rated insulation voltage: Power circuit: 600 V conforming to UL 508; Power circuit: 690 V conforming to IEC 60947-4-1; Signalling circuit: 690 V conforming to IEC 60947-4-1; Signalling circuit: 690 V conforming to IEC 60947-5-1; Signalling circuit: 600 V conforming to UL 508; Power circuit: 600 V conforming to CSA C22.2 No 14; Signalling circuit: 600 V conforming to CSA C22.2 No 14 Insulation resistance: > 10 MOhm for signalling circuit Inrush power in W: 3 W (at 20 °C) Hold-in power consumption in W: 3 W at 20 °C Heat dissipation: 1.3 W Control circuit voltage limits: Operational: 0.8...1.15 Uc (at = 0.10 Uc (at <50 °C) Connections - terminals: Screw clamp terminals 1 cable(s) 1.5…4 mm²solid; Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable end; Screw clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable end; Screw clamp terminals 2 cable(s) 1.5…4 mm²solid; Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end; Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end; Power circuit: screw clamp terminals 2 cable(s) 1.5 mm²flexible with cable end Maximum operating rate: 3600 cyc/h Coil technology: Without built-in suppressor module Auxiliary contacts type: type instantaneous 1 NO minimum switching current: 5 mA for signalling circuit minimum switching voltage: 17 V for signalling circuit Mounting support: Rail; Plate Tightening torque: 0.8…1.3 N.m - on screw clamp terminals Philips No 2; 0.8…1.3 N.m - on screw clamp terminals flat Ø 6 mm; 0.8…1.3 N.m - on screw clamp terminals pozidriv No 2 Operating time: 30...40 ms coil energisation and NO closing; 10 ms coil de-energisation and NO opening Safety reliability level: B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 Mechanical durability: 10 Mcycles Electrical durability: 1.3 Mcycles 9 A AC-3 at Ue <= 440 V; 1.3 Mcycles 9 A AC-3e at Ue <= 440 V; 0.16 Mcycles 20 A AC-1 at Ue <= 690 V; 0.02 Mcycles 54 A AC-4 at Ue <= 440 V Height: 58 mm Width: 45 mm Depth: 57 mm Product weight: 0.225 kg Standards: EN/IEC 60947-4-1; EN/IEC 60947-5-1; UL 60947-4-1; UL 60947-5-1; CSA C22.2 No 60947-4-1; CSA C22.2 No 60947-5-1; GB/T 14048.4 Product certifications: CB Scheme; CCC; UL; CSA; EAC; CE; UKCA IP degree of protection: IP2X Ambient air temperature for operation: -25…50 °C Ambient air temperature for storage: -50…80 °C Operating altitude: 2000 m without derating Flame retardance: V1 conforming to UL 94; Requirement 2 conforming to NF F 16-101; Requirement 2 conforming to NF F 16-102 Country of origin: FR Warranty (in months): 18
Standards & Compliance
- HS Code
- 8536.90
Cross References
- EAN 3389110363241
- SAP 1000030969
- Code 8733185
Product Documentation
More from Schneider Electric

Schneider Electric
Schneider Electric ZB5AA434 red flush pushbutton head Ø22 spring return "STOP

Schneider Electric
Schneider Electric IEM3350 energy meter - 125 A - Modbus A9MEM3350

Schneider Electric
Schneider Electric MN undervoltage release, ComPacT NSX, rated voltage 250 VDC, screwless spring terminal connections LV429414

Schneider Electric
Schneider Electric signalling contacts LUA - 1 NO + 1 NC LUA1C11

Schneider Electric
Schneider Electric Trip unit MicroLogic 5.2E, ComPacT NSX100/160/250, 4 poles, electronic basic protections, energy meter, 100A rating C1045E100

Schneider Electric
Schneider Electric Trip unit MicroLogic 5.3E, ComPacT NSX400/630, 3 poles, electronic basic protections, energy meter, 400A rating C4035E400

Schneider Electric
Schneider Electric impulse relay iTLI - 2P - 1NO+1NC - 16A - coil 110 VDC - 230...240 VAC 50/60Hz A9C30815

Schneider Electric
Terminal block, double terminal vert. 35 mm²
A9XPCM04
Technical guides
Catalogue entry last verified: 2026-09-29. A manufacturer datasheet is attached to this entry — confirm application-critical values against it.
Frequently asked questions
- Where can I buy LP1K0910BD?
- LP1K0910BD can be ordered from cballast.com as a Schneider Electric catalogue item: request a quotation on this page or email sales@cballast.com, and the order ships worldwide.
- What is the manufacturer part number for this Schneider Electric product?
- The manufacturer part number is LP1K0910BD.
- What is the HS code for LP1K0910BD?
- The customs tariff (HS) code for LP1K0910BD is 8536.90.
- Who manufactures LP1K0910BD?
- LP1K0910BD is a Schneider Electric product in the Electrical Components range.
- Is a datasheet available for LP1K0910BD?
- Yes — the LP1K0910BD datasheet can be viewed and downloaded on this page.
- What is the minimum order quantity for LP1K0910BD?
- The minimum order quantity is 1.
- Is LP1K0910BD available?
- Yes — LP1K0910BD is available to order: fulfilment is from supplier stock in cBallast's European network, dispatched directly from the warehouse to the customer, with the exact lead time stated in the quotation (reply within 24 hours).
