
Fluke 3000 FC Series Wireless Multimeter
Pricing
Request a quote
We reply within 24 hours
Product Description
Improve safety & efficiency with Fluke 3000 FC series wireless multimeter. Get true-RMS voltage, current measurements frequency, diode measurements & more!
Technical Specifications
- Manufacturer part number (MPN)
- 4401595 Brand: Fluke Category: Tools Fluke 115 Field Technicians digital Multimeter: Fluke 87V Industrial Multimeter CAT rating CAT III 600 V: CAT III 1000 V CAT IV 600 V Voltage AC/DC 600 V: 1000 V Resistance 40 MΩ: 50 MΩ Temperature -: -200.0 °C to 1090 °C Additional measurement capabilities Continuity/diode test: Frequency, continuity/diode test, motor drive (VFD) measurement, duty cycle, microamps, analogue bar graph, relative reference Accuracy2 3 4 45 Hz to 500 Hz: 1.0% + 3 Accuracy2 3 4 500 Hz to 1 kHz: 2.0% + 3 mV Range / resolution: 600.0 mV / 0.1 mV mV Accuracy: 0.09% + 2 V Range / resolution: 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V 1000 V / 1 V V Accuracy: 0.09% + 2 0.15% + 2 ))) Range / resolution: 600 Ω / 1 Ω ))) Accuracy: Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer. Diode test Range / resolution: 2.000 V / 0.001 V Diode test Accuracy: 1% + 2 µF Range / resolution: 1000 nF / 1 nF 10.00 μF / 0.01 μF 100.0 μF / 0.1 μF 9999 μF1 / 1 μF µF Accuracy: 1.2% + 2 10% typical mA AC (45 Hz to 1 kHz) Range1 / resolution: 60.00 mA / 0.01 mA 400.0 mA3 / 0.1 mA mA AC (45 Hz to 1 kHz) Accuracy: 1.5% + 3 mA DC2 Range1 / resolution: 60.00 mA / 0.01 mA 400.0 mA3 / 0.1 mA mA DC2 Accuracy: 0.5% + 3 Accuracy1: 0.1% + 1 Overload protection: 1100 V RMS Input impedance (nominal): > 10 MΩ < 100 pF Common mode rejection ratio (1 kΩ unbalance): > 120 dB at DC, 50 Hz or 60 Hz Normal mode rejection: > 60 dB at 50 Hz or 60 Hz Full scale voltage to 6 MΩ Full scale voltage 50 MΩ: < 0.7 V DC < 0.9 V DC Typical short circuit current: < 350 mA Overload: 600 mA overload for 2 minutes maximum, 10 minutes rest minimum DC functions: ± 12 counts for changes > 350 mS in duration. AC functions: ± 40 counts for changes > 900 mS in duration. Maximum voltage between any terminal and earth ground: 1000 V DC or AC RMS Ω fuse protection from A inputs: 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only Display (LCD) Update rate: 4/sec Display (LCD) Volts, amps, ohms: 6000 counts Display (LCD) Frequency: 10,000 counts Capacitance: 1,000 counts Battery type: Three AA Alkaline batteries, NEDA 15A IEC LR6 Battery life: 250 hours minimum RF communications: 2.4 GHZ ISM Band RF communication range Open air, unobstructed: Up to 20m RF communication range Obstructed, sheetrock wall: Up to 6.5m Obstructed, concrete wall, or steel electrical enclosure: Up to 3.5m Temperature Operating: -10°C to 50°C Temperature Storage: -40°C to 60°C Temperature coefficient: 0.1 X (specified accuracy) / °C ( 28°C) Relative humidity: 0% to 90% (0°C to 35°C) 0% to 75% (35°C to 40°C) 0% to 45% (40°C to 50°C) Altitude Operating: 2,000 m Altitude Storage: 12,000 m Electromagnetic compatibility EMI, RFI, EMC, RF: EN 61326–1:2006, EN 61326–2–2:2006 ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489 V1.8.1:2008 FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249 FCCID : FCC: T68–FDMMBLE IC: 6627A–FDMMBLE Safety compliance: ANSI / ISA 61010–1 / (82.02.01): 3rd edition CAN / CSA-C22.2 No 61010-1-12: 3rd edition UL 61010–1: 3rd edition IEC / EN 61010–1:2010 Certifications: CSA, FCC, CE Ingress Protection (IP) rating: IP54 Pollution Degree: 2 Size (H x W x L): 4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14 in) Weight: 340 g (12 oz) Warranty: Three years
Standards & Compliance
- HS Code
- 9030.33
Cross References
- OEM-URL https://www.fluke.com/en-us/product/electrical-testing/digital-multimeters/fluke-3000-fc
Product Documentation
More from Fluke

Fluke
Fluke V3000 FC Wireless AC Voltage Kit
4465641

Fluke
Fluke 1625-2 GEO Earth Ground Tester
4325162

Fluke
Fluke T3000 FC Wireless Temperature Kit
4465652

Fluke
P5523 Liquid to Gas Media Separator
FLUKE-CALIBRATION-P5523

Fluke
Fluke Calibration 1524 Handheld Thermometer Readout
3376600

Fluke
Fluke 3130-G2M Portable Pressure Calibrator
4317885

Fluke
P5543 Angle Adapter
3875955

Fluke
Fluke 719PRO Electric Pressure Calibrator
4353218
Catalogue entry last verified: 2026-10-03. A manufacturer datasheet is attached to this entry — confirm application-critical values against it.
Frequently asked questions
- Where can I buy 4401595?
- 4401595 can be ordered from cballast.com as a Fluke catalogue item: request a quotation on this page or email sales@cballast.com, and the order ships worldwide.
- What is the manufacturer part number for this Fluke product?
- The manufacturer part number is 4401595.
- What is the HS code for 4401595?
- The customs tariff (HS) code for 4401595 is 9030.33.
- Who manufactures 4401595?
- 4401595 is a Fluke product in the Safety & Detection range.
- Is a datasheet available for 4401595?
- Yes — the 4401595 datasheet can be viewed and downloaded on this page.
- What is the minimum order quantity for 4401595?
- The minimum order quantity is 1.
- Is 4401595 available?
- Yes — 4401595 is available to order: fulfilment is from supplier stock in cBallast's European network, dispatched directly from the warehouse to the customer, with the exact lead time stated in the quotation (reply within 24 hours).
