The Eaton 167909 is a residual current circuit breaker (RCCB) from the Moeller series xEffect FRCdM range. It disconnects the circuit when the current flowing out does not match the current returning — the signature of a fault to earth, whether through failed insulation or through a person. It provides no overcurrent protection of its own and is installed together with the circuit's MCB or fuse. This device is 4-pole, rated 40 A, with a rated residual current of 300 mA. Type Bfq is Eaton's type B variant with a tripping curve adapted to reliably sense residual currents up to 50 kHz. It is the frequency-converter type, for installations whose normal operating leakage is itself high-frequency and would otherwise cause nuisance tripping or, worse, mask a real fault. Bfq and B+ are not interchangeable: B+ is chosen for fire protection, Bfq for drive-heavy installations. It is the S (selective) version, which trips with a deliberate time delay so that an instantaneous RCD downstream clears the fault first and only the affected circuit is lost. A selective device belongs at the head of a board, not on a final circuit. At 300 mA it is intended for protection against earth-fault fire and for equipment protection, not for protection against direct contact — that requires a 30 mA device. Supplied by cBallast on quote-to-invoice terms; lead time and freight are quoted per RFQ against the destination Incoterm.
Technical Specifications
- Manufacturer part number (MPN)
- 167909
- EAN / GTIN
- 4015081644841
- HS code
- 8536.90
- Sales unit
- pcs
- Package quantity
- 30 pcs
- Eaton catalogue number
- 167909
- Depth
- 76 mm
- Height
- 80 mm
- Width
- 70 mm
- Weight
- 0.32 kg
- Compliances
- RoHS conform
- Certifications
- IEC/EN 61008; IEC/EN 62423; EN45545-2; IEC 61373
- Features
- Residual current circuit-breakers, digital; Selective protection; Additional equipment possible
- Fitted with
- Interlocking device
- Used with
- Residual current circuit-breakers, digital; Type S/Bfq; FRCdM
- Amperage Rating
- 40 A
- Application
- xEffect - Switchgear for industrial and advanced commercial applications
- Fault current rating
- 300 mA
- Impulse withstand current
- 5 kA (8/20 μs) surge-proof
- Number of poles
- Four-pole
- Rated short-circuit strength
- 10 kA
- Sensitivity type
- All current sensitive - frequency converter-proof
- Tripping time
- Selective switch off; 40 ms delayed - selective switch off
- Type
- FRCdM Residual current circuit-breakers, digital Type S/Bfq
- Ambient operating temperature - max
- 60 °C
- Ambient operating temperature - min
- -25 °C
- Equipment heat dissipation, current-dependent
- 6.2 W
- Heat dissipation capacity
- 6.2 W
- Heat dissipation per pole, current-dependent
- 0 W
- Rated operational current for specified heat dissipation (In)
- 40 A
- Static heat dissipation, non-current-dependent
- 0 W
- Admissible back-up fuse
- 63 A gG/gL
- Admissible back-up fuse overload - max
- 40 A gG/gL
- Frequency rating
- 50 Hz
- Leakage current type
- B
- Lifespan, electrical
- 4000 operations
- Pollution degree
- 2
- Radiation resistance
- Suitable for variable frequency drives (enhanced sensitivity)
- Rated fault current - max
- 0.3 A
- Rated fault current - min
- 0.3 A
- Rated impulse withstand voltage (Uimp)
- 4 kV
- Rated insulation voltage (Ui)
- 440 V
- Rated operational voltage (Ue) - max
- 415 V
- Rated residual making and breaking capacity
- 500 A
- Rated short-time withstand current (Icw)
- 10 kA
- Short-circuit rating
- 63 A (max. admissible back-up fuse)
- Surge current capacity
- 5 kA
- Test circuit range
- 196 V AC - 456 V AC
- Voltage rating - max
- 456 VAC
- Voltage rating - min
- 50 VAC
- Voltage rating (IEC/EN 60947-2)
- 240 V AC / 415 V AC
- Switching capacity of auxiliary contact - min
- 10 μA, 10 mV DC
- Switching current of auxiliary contact - max
- 2 A
- Switching duty with resistive load of auxiliary contact - max
- 60 W
- Switching voltage at AC of auxiliary contact - max
- 240 V
- Switching voltage at DC of auxiliary contact - max
- 220 V
- Terminal capacity of auxiliary contact
- 0.25 mm² - 1.5 mm²
- Built-in depth
- 70.5 mm
- Built-in width (number of units)
- 70 mm (4 SU)
- Busbar material thickness
- 0.8 mm - 2 mm
- Climatic proofing
- 25-55 °C / 90-95% relative humidity according to IEC 60068-2
- Connectable conductor cross section (multi-wired) - max
- 16 mm²
- Connectable conductor cross section (multi-wired) - min
- 1.5 mm²
- Connectable conductor cross section (solid-core) - max
- 35 mm²
- Connectable conductor cross section (solid-core) - min
- 1.5 mm²
- Contact position indicator color
- Red / green
- Degree of protection
- IP20, IP40 with suitable enclosure; IP20
- Frame
- 45 mm
- Lifespan, mechanical
- 20000 operations
- Mounting Method
- DIN rail; Quick attachment with 2 latch positions for DIN-rail IEC/EN 60715
- Mounting position
- As required
- Permitted storage and transport temperature - max
- 60 °C
- Permitted storage and transport temperature - min
- -35 °C
- Status indication
- White / blue
- Terminal capacity (cable)
- M5 (with cross-recessed screw as defined in EN ISO 4757-Z2, PZ2)
- Terminal capacity (solid wire)
- 1.5 mm² - 35 mm²
- Terminal capacity (stranded cable)
- 16 mm² (2x)
- Terminal protection
- Finger and hand touch safe, DGUV VS3, EN 50274
- Terminals (top and bottom)
- Twin-purpose terminals
- Tightening torque
- 2 Nm - 2.4 Nm
- Width in number of modular spacings
- 4
- Product family
- Eaton Moeller series xEffect FRCdM RCCB
- Device type
- Residual current circuit breaker (RCCB), no integral overcurrent protection
- Residual current type
- Type Bfq
- Rated residual current (IΔn)
- 300 mA
- Rated current
- 40 A
- Tripping characteristic
- Selective (S)
- Selection note
- Frequency-converter variant — reliable sensing up to 50 kHz
- Protection purpose
- Protection against earth-fault fire / equipment protection
Standards & Compliance
- HS Code
- 8536.90
Cross References
- EAN 4015081644841
- SAP 1000700533
- Code 8416648
- MPN 167909
- Type Bfq
Product Documentation
More from Eaton

Eaton
Rotary switch with light, Flat Front (M30C-FWLK-W)

Eaton
Joystick, Flat Front (M30C-FWRJS2H)

Eaton
Selector Switch (T6-3-8212/E/HI12)

Eaton
Eaton 9PX 11000I 3:1 6U HS NP
9PX11KiRTNBP31

Eaton
Protection IP2X NZM3-4-XIPK

Eaton
Residual current circuit breaker 40A 2P 100MA G/A
PFIM-40/2/01-G/A

Eaton
Star-delta switch (T5B-4-3/E)

Eaton
Maintenanceswitch,PV-20A-2P-AC-I1/SVB-SW
Catalogue entry last verified: 2026-09-29. A manufacturer datasheet is attached to this entry — confirm application-critical values against it.
Frequently asked questions
- Where can I buy 167909?
- 167909 can be ordered from cballast.com as a Eaton catalogue item: request a quotation on this page or email sales@cballast.com, and the order ships worldwide.
- What is the manufacturer part number for this Eaton product?
- The manufacturer part number is 167909.
- What is the HS code for 167909?
- The customs tariff (HS) code for 167909 is 8536.90.
- Who manufactures 167909?
- 167909 is a Eaton product in the Electrical Components range.
- Is a datasheet available for 167909?
- Yes — the 167909 datasheet can be viewed and downloaded on this page.
- What is the minimum order quantity for 167909?
- The minimum order quantity is 1.
- Is 167909 available?
- Yes — 167909 is available to order: fulfilment is from supplier stock in cBallast's European network, dispatched directly from the warehouse to the customer, with the exact lead time stated in the quotation (reply within 24 hours).