Schneider Electric Circuit breaker, ComPacT NSXm 63H, 70KA/415VAC, 4 poles 4D (neutral fully protected), TMD trip unit 16A, lugs/busbars C11H4TM016B
Pricing
Request a quote
We reply within 24 hours
Product Description
Schneider Electric C11H4TM016B Circuit breaker ComPacT NSXm H 100kA/230V 70kA/400V-with thermomagnetic protection-TM16D 4p bolt 16A.
Technical Specifications
- Manufacturer part number (MPN)
- C11H4TM016B
- EAN / GTIN
- 3606481992260
- HS code
- 8536.90
- Sales unit
- pcs
- Trip unit
- TM16D
- Range
- ComPacT
- Product name
- ComPacT NSXm
- Device short name
- NSXm 63H
- Product or component type
- Circuit breaker
- Device application
- Distribution
- Poles description
- 4P
- Protected poles description
- 4D
- Neutral position
- Left
- [In] rated current
- 16 A at 40 °C
- [Ue] rated operational voltage
- 690 V AC 50/60 Hz
- Network type
- AC
- Network frequency
- 50/60 Hz
- Suitability for isolation
- Yes conforming to IEC 60947-2
- Utilisation category
- Category A
- [Icu] rated ultimate short-circuit breaking capacity
- 100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2; 70 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2; 65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2; 30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2; 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2; 10 kA Icu at 660...690 V AC 50/60 Hz conforming to IEC 60947-2
- Performance level
- H 70 kA 415 V AC
- Trip unit name
- TM-D
- Trip unit technology
- Thermal-magnetic
- Trip unit protection functions
- LI
- Control type
- Toggle
- Circuit breaker mounting mode
- Fixed
- [Ui] rated insulation voltage
- 800 V AC 50/60 Hz
- [Uimp] rated impulse withstand voltage
- 8 kV
- [Ics] rated service short-circuit breaking capacity
- 100 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2; 70 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2; 65 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2; 30 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2; 22 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2; 2.5 kA at 660...690 V AC 50/60 Hz conforming to IEC 60947-2
- Mechanical durability
- 20000 cycles
- Electrical durability
- 20000 cycles at 440 V In/2; 10000 cycles at 440 V In; 10000 cycles at 690 V In/2; 5000 cycles at 690 V In
- Power dissipation per pole
- 2.3 W
- Mounting support
- Backplate
- Mounting position
- Horizontal and vertical; Flat on the back
- Upside connection
- Front
- Downside connection
- Front
- Connection terminals
- compression lug/busbar
- Connection pitch
- 35 mm with spreaders; 27 mm without spreaders
- 9 mm pitches
- 12 module
- Trip unit rating
- 16 A at 40 °C
- Long-time pick-up adjustment type Ir (thermal protection)
- Adjustable
- [Ir] long-time protection pick-up adjustment range
- 0.7...1 x In
- Long-time protection delay adjustment type tr
- Fixed
- Neutral protection settings
- 1 x Ir (4D)
- Instantaneous protection pick-up adjustment type Ii
- Fixed
- [Ii] instantaneous protection pick-up adjustment range
- 500 A
- Earth-leakage protection
- Without
- Number of slots for electrical auxiliaries
- 1 slot(s) for auxiliary switch OF; 1 slot(s) for alarm switch SD; 1 slot(s) for voltage release MN or MX
- Local signalling
- Flag (green) for presence of auxiliary contacts
- Width (W)
- 108 mm
- Height (H)
- 137 mm
- Depth (D)
- 80 mm
- Product weight
- 1.42 kg
- Colour
- Grey (RAL 7016)
- Standards
- EN/IEC 60947-2
- Overvoltage category
- III
- Electrical shock protection class
- Class I on front face
- Pollution degree
- 3 conforming to IEC 60664-1
- IP degree of protection
- IP40 conforming to IEC 60529
- IK degree of protection
- IK07 conforming to IEC 62262
- Ambient air temperature for operation
- -25…70 °C
- Ambient air temperature for storage
- -50…85 °C
- Relative humidity
- 0…95 %
- Operating altitude
- 2000 m without derating; 5000 m with derating
- Number of Units in Package 1
- 1
- Number of Units in Package 2
- 6
- Number of Units in Package 3
- 144
- Warranty (in months)
- 18
Standards & Compliance
- HS Code
- 8536.90
Cross References
- EAN 3606481992260
- SAP 1200534377
- Code 82688524
Product Documentation
More from Schneider Electric

Schneider Electric
Schneider Electric SMX 316L stainless monobloc enclosure, H1800XW800XD400MM, Scotch Brite® finish. NSYSMX18840H

Schneider Electric
Schneider Electric Floor standing enclosure polyester vers.PLA completely sealed 750X750X420 IP65 NSYPLA774G

Schneider Electric
Schneider Electric ACTI9 centralized control iATLc A9C15404

Schneider Electric
Divisible current transformer HD030 300/5A
METSECT5HD030

Schneider Electric
SWM Pole Mount W800 (NSYSFPSC80)

Schneider Electric
Silicone-Button (XACB9122)

Schneider Electric
Push-button flush white with text (ZB4FA133)

Schneider Electric
Angle and Wall bracket 50X50
NSYCMUMA50
Technical guides
Catalogue entry last verified: 2026-09-29. A manufacturer datasheet is attached to this entry — confirm application-critical values against it.
Frequently asked questions
- Where can I buy C11H4TM016B?
- C11H4TM016B can be ordered from cballast.com as a Schneider Electric catalogue item: request a quotation on this page or email sales@cballast.com, and the order ships worldwide.
- What is the manufacturer part number for this Schneider Electric product?
- The manufacturer part number is C11H4TM016B.
- What is the HS code for C11H4TM016B?
- The customs tariff (HS) code for C11H4TM016B is 8536.90.
- Who manufactures C11H4TM016B?
- C11H4TM016B is a Schneider Electric product in the Electrical Components range.
- Is a datasheet available for C11H4TM016B?
- Yes — the C11H4TM016B datasheet can be viewed and downloaded on this page.
- What is the minimum order quantity for C11H4TM016B?
- The minimum order quantity is 1.
- Is C11H4TM016B available?
- Yes — C11H4TM016B is available to order: fulfilment is from supplier stock in cBallast's European network, dispatched directly from the warehouse to the customer, with the exact lead time stated in the quotation (reply within 24 hours).