PhD sc digital pH-sensor Peek Insertion — Mounting 1" NPT DPD2P1
Hach

PhD sc digital pH-sensor Peek Insertion — Mounting 1" NPT DPD2P1

Part numberDPD2P1HS code9027.89
MOQ:1

Pricing

Request a quote

We reply within 24 hours

Product Description

Hach PhD sc digital pH-sensor Peek Insertion — Mounting 1" NPT DPD2P1.

Technical Specifications

Accuracy
± 0.02 pH
Body material
PEEK
Cable Connection
Digital
Cable Length
10 m PUR (polyurethane) 4-conductor with one shield, rated to 105°C
Calibration Method
Two point automatic, one point automatic, two point manual, one point manual
Communication
Modbus
Compliance
Hazardous location, Maritime, CE
Drift
0.03 pH per 24 hours, non-cumulative
Electrode Type
General Purpose
Flow Rate
3 m (10 ft.) per second, maximum
Length
271.3 mm
Mounting
Insertion
Operating Temperature Range
-5 - 70 °C (23 - 158 °F) pHD and ORP; 0 - 50 °C (32 - 122 °F) SS pHD; Before initial pH calibration, calibrate the temperature measurement when the sensor is in water or buffer which is at approximately the same temperature as the pH buffers (matches current recommendation)
Pressure Range
Maximum 10.7 bar . 6.9 bar for Digital Sensor at 70°C, and 6.9 bar for Analog Sensor at 105°C.
Range
-2.0 to 14.0 pH
Repeatability
± 0.05 pH
Sensitivity
± 0.01 pH
Sensor Cable
(integral) 4 10 m (33 ft.) polyurethane, 4-conductor cable with one shield, rated to 105°C (221°F)
Sensor Thread
1" NPT
Storage Conditions
4 - 70°C, 0-95% relative humidity (non-condensing)
Temperature Accuracy
± 0.5 °C (± 0.9 °F)
Temperature Compensation
Automatic with NTC 300 Ω thermistor, or manually fixed at a user-entered temperature; additional selectable temperature correction factors (ammonia, morpholine, or user-defined pH/°C linear slope) available for pure water automatic compensation 0.0 - 50 °C
Temperature Sensor
NTC 300 Ω thermistor for automatic temperature compensation and analyzer temperature readout
Transmission Distance
100 m (328 ft.), maximum; 1000 m (3280 ft.), maximum when used with a termination box.
Warranty
0-12 months, full replacement; 13-18 months, sensor is replaced at approx. 1/3 current strip price (from date of shipment); 19-30 months, sensor is replaced at approx. 2/3 current strip price (from date of shipment)
Weight
0.316 kg
What's included
Includes: sensor with 33 ft cable and manual

Standards & Compliance

HS Code
9027.89

Catalogue entry last verified: 2026-10-03. A manufacturer datasheet is attached to this entry — confirm application-critical values against it.

Frequently asked questions

Where can I buy DPD2P1?
DPD2P1 can be ordered from cballast.com as a Hach catalogue item: request a quotation on this page or email sales@cballast.com, and the order ships worldwide.
What is the manufacturer part number for this Hach product?
The manufacturer part number is DPD2P1.
What is the HS code for DPD2P1?
The customs tariff (HS) code for DPD2P1 is 9027.89.
Who manufactures DPD2P1?
DPD2P1 is a Hach product in the Chemical Test Kits range.
Is a datasheet available for DPD2P1?
Yes — the DPD2P1 datasheet can be viewed and downloaded on this page.
What is the minimum order quantity for DPD2P1?
The minimum order quantity is 1.
Is DPD2P1 available?
Yes — DPD2P1 is available to order: fulfilment is from supplier stock in cBallast's European network, dispatched directly from the warehouse to the customer, with the exact lead time stated in the quotation (reply within 24 hours).