Eaton xEffect FRCdM Residual Current Circuit Breaker (RCCB) — Type B+, 4-Pole, 63 A, 300 mA, Selective (FRCDM-63/4/03-S/B+)
Eaton

Eaton xEffect FRCdM Residual Current Circuit Breaker (RCCB) — Type B+, 4-Pole, 63 A, 300 mA, Selective

Part numberFRCDM-63/4/03-S/B+EAN / GTIN4015081644667HS code8536.90
MOQ:1

Pricing

Request a quote

We reply within 24 hours

Product Description

The Eaton FRCDM-63/4/03-S/B+ is a residual current circuit breaker (RCCB) from the Moeller series xEffect FRCdM range. It disconnects the circuit when the current flowing out does not match the current returning — the signature of a fault to earth, whether through failed insulation or through a person. It provides no overcurrent protection of its own and is installed together with the circuit's MCB or fuse. This device is 4-pole, rated 63 A, with a rated residual current of 300 mA. Type B+ responds to all forms of residual current and adds a tripping curve that holds the trip threshold to a maximum of 420 mA all the way up to 20 kHz. That ceiling is what makes it the fire-protection type: it limits the energy a high-frequency earth fault can put into an arc. Specify B+ where the concern is electrically ignited fire. It is the S (selective) version, which trips with a deliberate time delay so that an instantaneous RCD downstream clears the fault first and only the affected circuit is lost. A selective device belongs at the head of a board, not on a final circuit. At 300 mA it is intended for protection against earth-fault fire and for equipment protection, not for protection against direct contact — that requires a 30 mA device. Supplied by cBallast on quote-to-invoice terms; lead time and freight are quoted per RFQ against the destination Incoterm.

Technical Specifications

Manufacturer part number (MPN)
FRCDM-63/4/03-S/B+
EAN / GTIN
4015081644667
HS code
8536.90
Sales unit
pcs
Package quantity
30 pcs
Eaton catalogue number
167890
Depth
76 mm
Height
80 mm
Width
70 mm
Weight
0.32 kg
Compliances
RoHS conform
Certifications
VDE 0664-400; EN45545-2; IEC 61373; IEC/EN 61008; IEC/EN 62423
Features
Selective protection; Residual current circuit-breakers, digital; Additional equipment possible
Fitted with
Interlocking device
Used with
FRCdM; Residual current circuit-breakers, digital; Type S/B+
Amperage Rating
63 A
Application
xEffect - Switchgear for industrial and advanced commercial applications
Fault current rating
300 mA
Impulse withstand current
5 kA (8/20 μs) surge-proof
Number of poles
Four-pole
Rated short-circuit strength
10 kA
Sensitivity type
All current sensitive
Tripping time
Selective switch off; 40 ms delayed - selective switch off
Type
FRCdM Residual current circuit-breakers, digital Type S/B+
Ambient operating temperature - max
60 °C
Ambient operating temperature - min
-25 °C
Equipment heat dissipation, current-dependent
10 W
Heat dissipation capacity
10 W
Heat dissipation per pole, current-dependent
0 W
Rated operational current for specified heat dissipation (In)
63 A
Static heat dissipation, non-current-dependent
0 W
Admissible back-up fuse
63 A gG/gL
Admissible back-up fuse overload - max
63 A gG/gL
Frequency rating
50 Hz
Leakage current type
B+
Lifespan, electrical
4000 operations
Pollution degree
2
Rated fault current - max
0.3 A
Rated fault current - min
0.3 A
Rated impulse withstand voltage (Uimp)
4 kV
Rated insulation voltage (Ui)
440 V
Rated operational voltage (Ue) - max
415 V
Rated residual making and breaking capacity
630 A
Rated short-time withstand current (Icw)
10 kA
Short-circuit rating
63 A (max. admissible back-up fuse)
Surge current capacity
5 kA
Test circuit range
196 V AC - 456 V AC
Voltage rating - max
456 VAC
Voltage rating - min
50 VAC
Voltage rating (IEC/EN 60947-2)
240 V AC / 415 V AC
Switching capacity of auxiliary contact - min
10 μA, 10 mV DC
Switching current of auxiliary contact - max
2 A
Switching duty with resistive load of auxiliary contact - max
60 W
Switching voltage at AC of auxiliary contact - max
240 V
Switching voltage at DC of auxiliary contact - max
220 V
Terminal capacity of auxiliary contact
0.25 mm² - 1.5 mm²
Built-in depth
70.5 mm
Built-in width (number of units)
70 mm (4 SU)
Busbar material thickness
0.8 mm - 2 mm
Climatic proofing
25-55 °C / 90-95% relative humidity according to IEC 60068-2
Connectable conductor cross section (multi-wired) - max
16 mm²
Connectable conductor cross section (multi-wired) - min
1.5 mm²
Connectable conductor cross section (solid-core) - max
35 mm²
Connectable conductor cross section (solid-core) - min
1.5 mm²
Contact position indicator color
Red / green
Degree of protection
IP20, IP40 with suitable enclosure; IP20
Frame
45 mm
Lifespan, mechanical
20000 operations
Mounting Method
DIN rail; Quick attachment with 2 latch positions for DIN-rail IEC/EN 60715
Mounting position
As required
Permitted storage and transport temperature - max
60 °C
Permitted storage and transport temperature - min
-35 °C
Status indication
White / blue
Terminal capacity (cable)
M5 (with cross-recessed screw as defined in EN ISO 4757-Z2, PZ2)
Terminal capacity (solid wire)
1.5 mm² - 35 mm²
Terminal capacity (stranded cable)
16 mm² (2x)
Terminal protection
Finger and hand touch safe, DGUV VS3, EN 50274
Terminals (top and bottom)
Twin-purpose terminals
Tightening torque
2 Nm - 2.4 Nm
Width in number of modular spacings
4
Product family
Eaton Moeller series xEffect FRCdM RCCB
Device type
Residual current circuit breaker (RCCB), no integral overcurrent protection
Residual current type
Type B+
Rated residual current (IΔn)
300 mA
Rated current
63 A
Tripping characteristic
Selective (S)
Selection note
Fire protection variant — trip limited to 420 mA up to 20 kHz
Protection purpose
Protection against earth-fault fire / equipment protection

Standards & Compliance

HS Code
8536.90

Cross References

  • EAN 4015081644667
  • SAP 1000722124
  • Code 8342885
  • MPN FRCDM-63/4/03-S/B+
  • Type B+

Catalogue entry last verified: 2026-09-29. A manufacturer datasheet is attached to this entry — confirm application-critical values against it.

Frequently asked questions

Where can I buy FRCDM-63/4/03-S/B+?
FRCDM-63/4/03-S/B+ can be ordered from cballast.com as a Eaton catalogue item: request a quotation on this page or email sales@cballast.com, and the order ships worldwide.
What is the manufacturer part number for this Eaton product?
The manufacturer part number is FRCDM-63/4/03-S/B+.
What is the HS code for FRCDM-63/4/03-S/B+?
The customs tariff (HS) code for FRCDM-63/4/03-S/B+ is 8536.90.
Who manufactures FRCDM-63/4/03-S/B+?
FRCDM-63/4/03-S/B+ is a Eaton product in the Electrical Components range.
Is a datasheet available for FRCDM-63/4/03-S/B+?
Yes — the FRCDM-63/4/03-S/B+ datasheet can be viewed and downloaded on this page.
What is the minimum order quantity for FRCDM-63/4/03-S/B+?
The minimum order quantity is 1.
Is FRCDM-63/4/03-S/B+ available?
Yes — FRCDM-63/4/03-S/B+ is available to order: fulfilment is from supplier stock in cBallast's European network, dispatched directly from the warehouse to the customer, with the exact lead time stated in the quotation (reply within 24 hours).