The Eaton FRCDM-63/4/03-G/B is a residual current circuit breaker (RCCB) from the Moeller series xEffect FRCdM range. It disconnects the circuit when the current flowing out does not match the current returning — the signature of a fault to earth, whether through failed insulation or through a person. It provides no overcurrent protection of its own and is installed together with the circuit's MCB or fuse. This device is 4-pole, rated 63 A, with a rated residual current of 300 mA. Type B responds to all forms of residual current — AC, pulsating DC and smooth DC — up to 1 kHz. It is required wherever a fault can present a smooth DC residual current that would blind a type A device, which in practice means circuits fed through frequency converters, rectifiers, EV chargers and photovoltaic inverters. It is the G (short-time delayed) version, which rides through the brief leakage surges that switching and cable capacitance produce at energisation instead of tripping on them. At 300 mA it is intended for protection against earth-fault fire and for equipment protection, not for protection against direct contact — that requires a 30 mA device. Supplied by cBallast on quote-to-invoice terms; lead time and freight are quoted per RFQ against the destination Incoterm.
Technical Specifications
- Manufacturer part number (MPN)
- FRCDM-63/4/03-G/B
- EAN / GTIN
- 4015081644650
- HS code
- 8536.90
- Sales unit
- pcs
- Package quantity
- 30 pcs
- Eaton catalogue number
- 167898
- Depth
- 76 mm
- Height
- 80 mm
- Width
- 70 mm
- Weight
- 0.32 kg
- Compliances
- RoHS conform
- Certifications
- ÖVE E 8601; IEC/EN 61008; IEC/EN 62423; EN45545-2; IEC 61373
- Features
- Additional equipment possible; Residual current circuit-breakers, digital; Selective protection
- Fitted with
- Interlocking device
- Functions
- Short-time delayed tripping
- Special features
- FRCdM Residual current circuit-breakers, digital Type G/B (ÖVE E 8601)
- Used with
- FRCdM; Residual current circuit-breakers, digital; Type G/B (�VE E 8601)
- Amperage Rating
- 63 A
- Application
- xEffect - Switchgear for industrial and advanced commercial applications
- Fault current rating
- 300 mA
- Impulse withstand current
- 3 kA (8/20 μs) surge-proof
- Number of poles
- Four-pole
- Rated short-circuit strength
- 10 kA
- Sensitivity type
- All current sensitive
- Tripping time
- Short time-delayed; 10 ms delayed
- Ambient operating temperature - max
- 40 °C
- Ambient operating temperature - min
- -25 °C
- Equipment heat dissipation, current-dependent
- 10 W
- Heat dissipation capacity
- 10 W
- Heat dissipation per pole, current-dependent
- 2.5 W
- Rated operational current for specified heat dissipation (In)
- 63 A
- Static heat dissipation, non-current-dependent
- 0 W
- Admissible back-up fuse
- 63 A gG/gL
- Admissible back-up fuse overload - max
- 63 A gG/gL
- Frequency rating
- 50 Hz
- Leakage current type
- B
- Lifespan, electrical
- 4000 operations
- Pollution degree
- 2
- Rated fault current - max
- 0.3 A
- Rated fault current - min
- 0.3 A
- Rated impulse withstand voltage (Uimp)
- 4 kV
- Rated insulation voltage (Ui)
- 440 V
- Rated operational voltage (Ue) - max
- 415 V
- Rated residual making and breaking capacity
- 630 A
- Rated short-time withstand current (Icw)
- 10 kA
- Short-circuit rating
- 63 A (max. admissible back-up fuse)
- Surge current capacity
- 3 kA
- Test circuit range
- 196 V AC - 456 V AC
- Voltage rating - max
- 456 VAC
- Voltage rating - min
- 50 VAC
- Voltage rating (IEC/EN 60947-2)
- 240 V AC / 415 V AC
- Switching capacity of auxiliary contact - min
- 10 μA, 10 mV DC
- Switching current of auxiliary contact - max
- 2 A
- Switching duty with resistive load of auxiliary contact - max
- 60 W
- Switching voltage at AC of auxiliary contact - max
- 240 V
- Switching voltage at DC of auxiliary contact - max
- 220 V
- Terminal capacity of auxiliary contact
- 0.25 mm² - 1.5 mm²
- Built-in depth
- 70.5 mm
- Built-in width (number of units)
- 70 mm (4 SU)
- Busbar material thickness
- 0.8 mm - 2 mm
- Climatic proofing
- 25-55 °C / 90-95% relative humidity according to IEC 60068-2
- Connectable conductor cross section (multi-wired) - max
- 16 mm²
- Connectable conductor cross section (multi-wired) - min
- 1.5 mm²
- Connectable conductor cross section (solid-core) - max
- 35 mm²
- Connectable conductor cross section (solid-core) - min
- 1.5 mm²
- Contact position indicator color
- Red / green
- Degree of protection
- IP20, IP40 with suitable enclosure; IP20
- Frame
- 45 mm
- Lifespan, mechanical
- 20000 operations
- Mounting Method
- Quick attachment with 2 latch positions for DIN-rail IEC/EN 60715; DIN rail
- Mounting position
- As required
- Permitted storage and transport temperature - max
- 60 °C
- Permitted storage and transport temperature - min
- -35 °C
- Status indication
- White / blue
- Terminal capacity (cable)
- M5 (with cross-recessed screw as defined in EN ISO 4757-Z2, PZ2)
- Terminal capacity (solid wire)
- 1.5 mm² - 35 mm²
- Terminal capacity (stranded cable)
- 16 mm² (2x)
- Terminal protection
- Finger and hand touch safe, DGUV VS3, EN 50274
- Terminals (top and bottom)
- Twin-purpose terminals
- Tightening torque
- 2 Nm - 2.4 Nm
- Width in number of modular spacings
- 4
- Product family
- Eaton Moeller series xEffect FRCdM RCCB
- Device type
- Residual current circuit breaker (RCCB), no integral overcurrent protection
- Residual current type
- Type B
- Rated residual current (IΔn)
- 300 mA
- Rated current
- 63 A
- Tripping characteristic
- Short-Time Delayed (G)
- Selection note
- All-current sensitive up to 1 kHz
- Protection purpose
- Protection against earth-fault fire / equipment protection
Standards & Compliance
- HS Code
- 8536.90
Cross References
- EAN 4015081644650
- SAP 1000700518
- Code 8149645
- MPN FRCDM-63/4/03-G/B
- Type B
Product Documentation
More from Eaton

Eaton
variable-frequency drive DM1-342D2EB-N20B-EM

Eaton
SOL30X3-Safety-MC4-U(230V50HZ) (168100)

Eaton
Eaton xEffect FRCdM Residual Current Circuit Breaker (RCCB) — Type B+, 4-Pole, 25 A, 30 mA, Short-Time Delayed
167880

Eaton
Eaton IZMX-PXRV-TA-1

Eaton
Residual current circuit breaker with overcurrent 13A 3P C 100MAA
PKPM3-13/3/C/01-A

Eaton
Safety Switch (P5-250/V/SVB)

Eaton
Eaton FAZ-Z25/1 Miniature Circuit Breaker — 1P, Type Z, 25 A, 15 kA

Eaton
Safety Switch (P5-160/V/SVB/N)
Catalogue entry last verified: 2026-09-29. A manufacturer datasheet is attached to this entry — confirm application-critical values against it.
Frequently asked questions
- Where can I buy FRCDM-63/4/03-G/B?
- FRCDM-63/4/03-G/B can be ordered from cballast.com as a Eaton catalogue item: request a quotation on this page or email sales@cballast.com, and the order ships worldwide.
- What is the manufacturer part number for this Eaton product?
- The manufacturer part number is FRCDM-63/4/03-G/B.
- What is the HS code for FRCDM-63/4/03-G/B?
- The customs tariff (HS) code for FRCDM-63/4/03-G/B is 8536.90.
- Who manufactures FRCDM-63/4/03-G/B?
- FRCDM-63/4/03-G/B is a Eaton product in the Electrical Components range.
- Is a datasheet available for FRCDM-63/4/03-G/B?
- Yes — the FRCDM-63/4/03-G/B datasheet can be viewed and downloaded on this page.
- What is the minimum order quantity for FRCDM-63/4/03-G/B?
- The minimum order quantity is 1.
- Is FRCDM-63/4/03-G/B available?
- Yes — FRCDM-63/4/03-G/B is available to order: fulfilment is from supplier stock in cBallast's European network, dispatched directly from the warehouse to the customer, with the exact lead time stated in the quotation (reply within 24 hours).