Eaton xEffect FRCdM Residual Current Circuit Breaker (RCCB) — Type B, 4-Pole, 40 A, 300 mA, Selective
Pricing
Request a quote
We reply within 24 hours
Product Description
The Eaton 167901 is a residual current circuit breaker (RCCB) from the Moeller series xEffect FRCdM range. It disconnects the circuit when the current flowing out does not match the current returning — the signature of a fault to earth, whether through failed insulation or through a person. It provides no overcurrent protection of its own and is installed together with the circuit's MCB or fuse. This device is 4-pole, rated 40 A, with a rated residual current of 300 mA. Type B responds to all forms of residual current — AC, pulsating DC and smooth DC — up to 1 kHz. It is required wherever a fault can present a smooth DC residual current that would blind a type A device, which in practice means circuits fed through frequency converters, rectifiers, EV chargers and photovoltaic inverters. It is the S (selective) version, which trips with a deliberate time delay so that an instantaneous RCD downstream clears the fault first and only the affected circuit is lost. A selective device belongs at the head of a board, not on a final circuit. At 300 mA it is intended for protection against earth-fault fire and for equipment protection, not for protection against direct contact — that requires a 30 mA device. Supplied by cBallast on quote-to-invoice terms; lead time and freight are quoted per RFQ against the destination Incoterm.
Technical Specifications
- Manufacturer part number (MPN)
- 167901
- EAN / GTIN
- 4015081644766
- HS code
- 8536.90
- Sales unit
- pcs
- Package quantity
- 30 pcs
- Eaton catalogue number
- 167901
- Depth
- 76 mm
- Height
- 80 mm
- Width
- 70 mm
- Weight
- 0.32 kg
- Compliances
- RoHS conform
- Certifications
- IEC/EN 62423; IEC/EN 61008; EN45545-2; IEC 61373
- Features
- Residual current circuit-breakers, digital; Additional equipment possible; Selective protection
- Fitted with
- Interlocking device
- Used with
- Residual current circuit-breakers, digital; Type S/B; FRCdM
- Amperage Rating
- 40 A
- Application
- xEffect - Switchgear for industrial and advanced commercial applications
- Fault current rating
- 300 mA
- Impulse withstand current
- 5 kA (8/20 μs) surge-proof
- Number of poles
- Four-pole
- Rated short-circuit strength
- 10 kA
- Sensitivity type
- All current sensitive
- Tripping time
- 40 ms delayed - selective switch off; Selective switch off
- Type
- FRCdM Residual current circuit-breakers, digital Type S/B
- Ambient operating temperature - max
- 60 °C
- Ambient operating temperature - min
- -25 °C
- Equipment heat dissipation, current-dependent
- 6.2 W
- Heat dissipation capacity
- 6.2 W
- Heat dissipation per pole, current-dependent
- 0 W
- Rated operational current for specified heat dissipation (In)
- 40 A
- Static heat dissipation, non-current-dependent
- 0 W
- Admissible back-up fuse
- 63 A gG/gL
- Admissible back-up fuse overload - max
- 40 A gG/gL
- Frequency rating
- 50 Hz
- Leakage current type
- B
- Lifespan, electrical
- 4000 operations
- Pollution degree
- 2
- Rated fault current - max
- 0.3 A
- Rated fault current - min
- 0.3 A
- Rated impulse withstand voltage (Uimp)
- 4 kV
- Rated insulation voltage (Ui)
- 440 V
- Rated operational voltage (Ue) - max
- 415 V
- Rated residual making and breaking capacity
- 500 A
- Rated short-time withstand current (Icw)
- 10 kA
- Short-circuit rating
- 63 A (max. admissible back-up fuse)
- Surge current capacity
- 5 kA
- Test circuit range
- 196 V AC - 456 V AC
- Voltage rating - max
- 456 VAC
- Voltage rating - min
- 50 VAC
- Voltage rating (IEC/EN 60947-2)
- 240 V AC / 415 V AC
- Switching capacity of auxiliary contact - min
- 10 μA, 10 mV DC
- Switching current of auxiliary contact - max
- 2 A
- Switching duty with resistive load of auxiliary contact - max
- 60 W
- Switching voltage at AC of auxiliary contact - max
- 240 V
- Switching voltage at DC of auxiliary contact - max
- 220 V
- Terminal capacity of auxiliary contact
- 0.25 mm² - 1.5 mm²
- Built-in depth
- 70.5 mm
- Built-in width (number of units)
- 70 mm (4 SU)
- Busbar material thickness
- 0.8 mm - 2 mm
- Climatic proofing
- 25-55 °C / 90-95% relative humidity according to IEC 60068-2
- Connectable conductor cross section (multi-wired) - max
- 16 mm²
- Connectable conductor cross section (multi-wired) - min
- 1.5 mm²
- Connectable conductor cross section (solid-core) - max
- 35 mm²
- Connectable conductor cross section (solid-core) - min
- 1.5 mm²
- Contact position indicator color
- Red / green
- Degree of protection
- IP20, IP40 with suitable enclosure; IP20
- Frame
- 45 mm
- Lifespan, mechanical
- 20000 operations
- Mounting Method
- Quick attachment with 2 latch positions for DIN-rail IEC/EN 60715; DIN rail
- Mounting position
- As required
- Permitted storage and transport temperature - max
- 60 °C
- Permitted storage and transport temperature - min
- -35 °C
- Status indication
- White / blue
- Terminal capacity (cable)
- M5 (with cross-recessed screw as defined in EN ISO 4757-Z2, PZ2)
- Terminal capacity (solid wire)
- 1.5 mm² - 35 mm²
- Terminal capacity (stranded cable)
- 16 mm² (2x)
- Terminal protection
- Finger and hand touch safe, DGUV VS3, EN 50274
- Terminals (top and bottom)
- Twin-purpose terminals
- Tightening torque
- 2 Nm - 2.4 Nm
- Width in number of modular spacings
- 4
- Product family
- Eaton Moeller series xEffect FRCdM RCCB
- Device type
- Residual current circuit breaker (RCCB), no integral overcurrent protection
- Residual current type
- Type B
- Rated residual current (IΔn)
- 300 mA
- Rated current
- 40 A
- Tripping characteristic
- Selective (S)
- Selection note
- All-current sensitive up to 1 kHz
- Protection purpose
- Protection against earth-fault fire / equipment protection
Standards & Compliance
- HS Code
- 8536.90
Cross References
- EAN 4015081644766
- SAP 1000700523
- Code 8149699
- MPN 167901
- Type B
Product Documentation
More from Eaton

Eaton
Eaton EC4P-222-MTAD1

Eaton
Eaton M22-WRLK3-W Illuminated Rotary Switch Maintained 1-0-2 White RMQ-Titan

Eaton
Eaton FRCMM-40/4/003-G/A (170295)

Eaton
Eaton AZ-4-C40 Miniature Circuit Breaker — 4P, Type C, 40 A, up to 25 kA

Eaton
Partition Plate plexiglass xE M H600 B1000
XPC0610

Eaton
INST.AUT. 1P C 16A
FAZ-C16/1-DC

Eaton
Selector Switch (026991)

Eaton
NH0 Switch-disconnector 3P160 BBL (XNH00-FCL-S160-BT1)
Catalogue entry last verified: 2026-09-29. A manufacturer datasheet is attached to this entry — confirm application-critical values against it.
Frequently asked questions
- Where can I buy 167901?
- 167901 can be ordered from cballast.com as a Eaton catalogue item: request a quotation on this page or email sales@cballast.com, and the order ships worldwide.
- What is the manufacturer part number for this Eaton product?
- The manufacturer part number is 167901.
- What is the HS code for 167901?
- The customs tariff (HS) code for 167901 is 8536.90.
- Who manufactures 167901?
- 167901 is a Eaton product in the Electrical Components range.
- Is a datasheet available for 167901?
- Yes — the 167901 datasheet can be viewed and downloaded on this page.
- What is the minimum order quantity for 167901?
- The minimum order quantity is 1.
- Is 167901 available?
- Yes — 167901 is available to order: fulfilment is from supplier stock in cBallast's European network, dispatched directly from the warehouse to the customer, with the exact lead time stated in the quotation (reply within 24 hours).