Danfoss AVQ flow controller, PN 25, DN 50, flow range 0.8–15 m³/h, Kvs 20 m³/h, G 2 1/2 A external thread
Pricing
Request a quote
We reply within 24 hours
Product Description
Danfoss AVQ (003H6729) — self-acting flow controller, PN 25, DN 50, for district heating and cooling systems. The AVQ is a self-acting flow controller for district heating and cooling systems. It holds the flow rate constant and closes when the set maximum flow is exceeded. It has a control valve with an adjustable flow restrictor and an actuator with one control diaphragm; the valve and actuator are delivered assembled with the impulse tube fitted. Flow range 0.8–15 m³/h; flow-restrictor differential pressure 0.2 bar; Kvs 20 m³/h. Maximum differential-pressure range 16 bar; media temperature 2–150 °C; cavitation factor z ≥ 0.6; seat leakage 0.05 % Kvs (IEC 60534). Valve body Ductile iron EN-GJS-400-18-LT (GGG 40.3); valve cone Dezincing free brass CuZn36Pb2As; seat Stainless steel, mat. No. 1.4571; control diaphragm EPDM. Connection External thread G 2 1/2 A (ISO 228/1), via tailpieces. Mounting version Free. Permissible media: District heating/cooling circulation water (Glycolic water up to 30%), pH 7–10. OEM P/N 003H6729. EAN 5702421542507. Technical data quoted verbatim from store.danfoss.com (code 003H6729) and the Danfoss AVQ data sheet.
Technical Specifications
- Code number
- 003H6729
- Type
- AVQ
- Product group
- Pressure and flow controllers
- Function
- Self-acting flow controller (closes when set max. flow is exceeded)
- Valve size
- DN 50
- Pressure class
- PN 25
- Connection
- External thread G 2 1/2 A (ISO 228/1), via tailpieces
- Kvs value
- 20 m³/h
- Flow rate range
- 0.8 - 15 m³/h
- Flow restrictor differential pressure (Δpb)
- 0.2 bar
- Max. differential pressure range
- 16 bar
- Media temperature
- 2 - 150 °C
- Media pH
- 7 - 10
- Cavitation factor z
- ≥ 0.6
- Seat leakage rate
- 0.05 % Kvs (IEC 60534)
- Mounting version
- Free
- Stem position
- Normally open
- Permissible media
- District heating/cooling circulation water (Glycolic water up to 30%)
- Valve body material
- Ductile iron EN-GJS-400-18-LT (GGG 40.3)
- Valve cone material
- Dezincing free brass CuZn36Pb2As
- Valve seat material
- Stainless steel, mat. No. 1.4571
- Actuator diaphragm
- EPDM
- EU RoHS compliance
- Yes with exemptions (6(c))
- REACH Candidate List substance
- Lead (CAS no. 7439-92-1)
- China RoHS
- Out of scope
- Net weight
- 6.088 kg
- Gross weight
- 6.088 kg
- EAN
- 5702421542507
Standards & Compliance
- Material
- Valve body Ductile iron EN-GJS-400-18-LT (GGG 40.3); valve cone Dezincing free brass CuZn36Pb2As; valve seat Stainless steel, mat. No. 1.4571; control diaphragm EPDM
- Pressure Rating
- PN 25 (max. differential-pressure range 16 bar)
- Temperature Range
- 2 to 150 °C (district heating/cooling water)
- HS Code
- 8481.80
Compatibility & Fitment
Danfoss AVQ for DN 50 district-heating/cooling flow control at PN 25. Set the maximum flow within 0.8–15 m³/h using the adjustable flow restrictor (Kvs 20 m³/h). Confirm the connection (External thread G 2 1/2 A (ISO 228/1), via tailpieces) and pressure class (PN 25) match the pipework; order the matching tailpiece/union-nut set separately. Maximum differential-pressure range 16 bar, media temperature up to 150 °C.
Product Documentation
More from Danfoss

Danfoss
Danfoss AVQ flow controller, PN 25, DN 32, flow range 0.4–10 m³/h, Kvs 12.5 m³/h, flanged
003H6730

Danfoss
Danfoss AVQ flow controller, PN 25, DN 40, flow range 0.8–12 m³/h, Kvs 20 m³/h, flanged
003H6731

Danfoss
Danfoss AVQ flow controller, PN 25, DN 50, flow range 0.8–15 m³/h, Kvs 25 m³/h, flanged
003H6732

Danfoss
Danfoss AVQM flow controller with integrated control valve (PICV), PN 16, DN 15, flow range 0.01–0.18 m³/h, Kvs 0.4 m³/h, G 3/4 A external thread
003H6733

Danfoss
Danfoss AVD pressure reduction controller, PN 25, DN 15, 1–5 bar adjustable, Kvs 0.4 m³/h, G 3/4 A external thread
003H6957

Danfoss
Danfoss AVD pressure reduction controller, PN 25, DN 15, 1–5 bar adjustable, Kvs 1 m³/h, G 3/4 A external thread
003H6958

Danfoss
Danfoss AVD pressure reduction controller, PN 25, DN 15, 3–12 bar adjustable, Kvs 1 m³/h, G 3/4 A external thread
003H6979

Danfoss
Danfoss AVQM flow controller with integrated control valve (PICV), PN 16, DN 15, flow range 0.02–0.4 m³/h, Kvs 1 m³/h, External thread G 3/4 A
003H6734
Technical guides
- Cross-Referencing Danfoss Refrigeration Components by IMPA and OEM Code
- Danfoss Product Code Decoder — 003Z, 013G, 017B, 023U, 027L, 032F, 060G, 060H, 065B, 065Z, 068Z, 084H, 132F, 148B Series (Complete Reference)
- Danfoss Maneurop MTZ Reciprocating Compressors — Model Range, Voltage Codes and Replacement Guide
Catalogue entry last verified: 2026-08-24. A manufacturer datasheet is attached to this entry — confirm application-critical values against it.
Frequently asked questions
- Where can I buy 003H6729?
- 003H6729 can be ordered from cballast.com as a Danfoss catalogue item: request a quotation on this page or email sales@cballast.com, and the order ships worldwide.
- What is the manufacturer part number for this Danfoss product?
- The manufacturer part number is 003H6729.
- What is the HS code for 003H6729?
- The customs tariff (HS) code for 003H6729 is 8481.80.
- Who manufactures 003H6729?
- 003H6729 is a Danfoss product in the HVAC & Refrigeration range.
- Is a datasheet available for 003H6729?
- Yes — the 003H6729 datasheet can be viewed and downloaded on this page.
- What is the minimum order quantity for 003H6729?
- The minimum order quantity is 1.
- Is 003H6729 available?
- Yes — 003H6729 is available to order: fulfilment is from supplier stock in cBallast's European network, dispatched directly from the warehouse to the customer, with the exact lead time stated in the quotation (reply within 24 hours).