Cross-references Danfoss refrigeration components (expansion valves, solenoid valves, pressure switches, filter driers) to their IMPA marine catalog codes and typical OEM alternatives. Covers TU / TE / TGE thermostatic expansion valves, EVR solenoid valves, KP / RT pressure switches, and DML / DCL filter driers. Includes selection rules for R404A, R410A, R448A, R449A and CO2 (R744) refrigerants.

Product families covered

Danfoss ships refrigeration components under distinct code families. Each family covers one function; within a family the code encodes the size and, where relevant, the refrigerant compatibility. The families listed below all appear regularly on IMPA marine stores requisitions and on shore-side commercial refrigeration BOMs.

Thermostatic expansion valves (TXV)

FamilyCapacity rangeRefrigerantsBodyTypical marine use
TU / TUA / TUAE / TUB / TUBE0.4 – 7.5 kWR404A, R448A, R449A, R452A, R134aStainlessReefer cargo, provision rooms
TE 51.0 – 8.0 kWR404A, R448A, R449A, R134aBrass, replaceable orificeProvision refrigeration
TE 127 – 30 kWR404A, R448A, R449A, R134aBrass, replaceable orificeReefer container plant rooms
TE 2013 – 60 kWR404A, R448A, R449A, R134aBrass, replaceable orificeChiller plants
TGE / TGEL2 – 40 kWR404A, R448A, R449A, R134a, R717 (ammonia)BrassIndustrial refrigeration

Solenoid valves

FamilyFunctionPortsRefrigerants
EVRDirect-acting on/off1/4" to 2 1/8" ODF / flareAll HFC, HCFC, R717
EVRSDirect-acting, stainless bodyCompactMarine, corrosive atmosphere
EVRAServo-actuated, larger orificeDN10 – DN40HFC, R717, R744
EVUUniversal, hermetic assemblies3/8" – 1/2"Compact plant

Pressure switches and pressure controls

FamilyFunctionCommon ranges
KP1 / KP2Low-pressure or high-pressure cut-out-0.9 to 7 bar (KP1); 8 to 32 bar (KP2)
KP5High-pressure safety, manual reset8 to 32 bar
KP15 / KP17Dual LP + HPCombined
RT-1A / RT-5AIndustrial pressure switch, manual/auto reset0.2 – 6 bar; 4 – 17 bar
MP54 / MP55AOil differential-pressure safety switch (compressor)0.3 – 4.5 bar Δp, 45-second time delay

Filter driers

FamilyDesiccantSealingRefrigerants
DML100% molecular sieveBrazed steel shellHFC / HFO (no oil breakdown)
DCL80% molecular sieve + activated aluminaBrazed steel shellHFC / HFO / retrofit lines
DASAcid burnout coreBrazed steel shellRecovery after compressor burnout
DCR (ELIMINATOR)Replaceable coreSolid-core or spunField-serviceable large systems

IMPA cross-reference notes

The IMPA Marine Stores Guide indexes Danfoss thermostatic and solenoid valves under section 79 (refrigeration). The listed IMPA code resolves to the Danfoss code number rather than the OEM part number, so buyers should verify the Danfoss code number against the Danfoss product store before issuing a purchase order. Where the vessel operator holds a class-society-approved BWMS or refrigeration plant, the Danfoss component's class-society type-approval certificate must accompany the delivery.