Danfoss AVPB differential pressure controller & flow limiter, PN 16, DN 20, Δp 0.2–1 bar adjustable, 0.1–4.5 m³/h, external thread G 1 A (003H6402)
Danfoss

Danfoss AVPB differential pressure controller & flow limiter, PN 16, DN 20, Δp 0.2–1 bar adjustable, 0.1–4.5 m³/h, external thread G 1 A

Part number003H6402Item numberCB-DANF-003H6402EAN / GTIN5702421539217HS code8481.80
MaterialValve body red bronze Rg 5 (CuSn5ZnPb, DIN 1705 W.no. 2.1096.01); valve insert/spindle CrNi steel 1.4404; control diaphragm EPDM
HVAC & Refrigeration
Balancing Valves
MOQ:1

Pricing

Request a quote

We reply within 24 hours

Product Description

Danfoss AVPB (003H6402) — self-acting differential pressure control and flow limiter, PN 16, DN 20, for district heating and central heating systems. The AVPB closes on rising differential pressure or when the set maximum flow is exceeded, holding a stable differential pressure across the controlled circuit so that connected control valves keep their authority. The controller combines a control valve with an adjustable flow restrictor and an actuator with one control diaphragm and handle for differential-pressure setting. Differential-pressure setting 0.2–1.0 bar adjustable; flow rate 0.1–4.5 m³/h. Maximum differential pressure 12 bar, maximum water temperature 140 °C, cavitation factor z ≥ 0.6. Valve body red bronze Rg 5 (CuSn5ZnPb, DIN 1705 W.no. 2.1096.01), control diaphragm EPDM, valve insert/spindle CrNi steel 1.4404. Connection external thread G 1 A (ISO 228/1) via tailpieces (ordered separately). Media: water for district/central heating; glycolic water up to 30% resistant to -30 °C. OEM P/N 003H6402. Technical data quoted verbatim from the Danfoss AVPB/AVPB-F PN 16 data sheet and store.danfoss.com (code 003H6402). 2.1096.01); valve insert/spindle CrNi steel 1.4404; control diaphragm EPDM; Pressure rating: PN 16 (max. differential pressure 12 bar); Temperature range: up to 140 °C (heating water); glycolic water resistant to -30 °C; HS code: 8481.80. Used in commercial refrigeration, provision-room cooling and reefer plant rooms across HFC, HFO and CO2 (R744) refrigerants.

Technical Specifications

Code number
003H6402
Type
AVPB
Product group
Pressure flow controllers
Description
Self-acting differential pressure control and flow limiter (district heating)
Valve size
DN 20
Pressure class
PN 16
Connection
External thread G 1 A (ISO 228/1), via tailpieces
Flow rate [m³/h]
0.1 - 4.5
Differential pressure setting
0.2 - 1 bar (adjustable, factory range)
Max. differential pressure
12 bar
Max. water temperature
140 °C
Cavitation factor z
≥ 0.6
Mounting version
Return
Permissible media
Water for district/central heating systems; glycolic water (≤30%) resistant to -30 °C
Valve body material
Red bronze Rg 5 (CuSn5ZnPb, DIN 1705 W.no. 2.1096.01)
Valve insert / spindle
CrNi steel 1.4404
Control diaphragm
EPDM
EU RoHS compliance
Yes with exemptions (6(c))
REACH Candidate List substance
Lead (CAS no. 7439-92-1)
EAN
5702421539217

Standards & Compliance

Material
Valve body red bronze Rg 5 (CuSn5ZnPb, DIN 1705 W.no. 2.1096.01); valve insert/spindle CrNi steel 1.4404; control diaphragm EPDM
Pressure Rating
PN 16 (max. differential pressure 12 bar)
Temperature Range
up to 140 °C (heating water); glycolic water resistant to -30 °C
HS Code
8481.80

Compatibility & Fitment

Danfoss AVPB for DN 20 district-heating or central-heating circuits. Size by the branch design flow (0.1–4.5 m³/h here) and set the differential-pressure setpoint within 0.2–1.0 bar. Confirm the connection (external thread G 1 A, ISO 228/1) and pressure class (PN 16) match the pipework; order the matching tailpiece/union-nut set and impulse tube separately. Maximum differential pressure 12 bar, maximum water temperature 140 °C.

Not sure if it fits? Email sales@cballast.com with your equipment serial number or photos — we confirm fit before you order.

Product Documentation

Document preview: Danfoss AVPB / AVPB-F (PN 16) differential pressure controller & flow limiter — Data Sheet

Catalogue entry last verified: 2026-08-29. A manufacturer datasheet is attached to this entry — confirm application-critical values against it.

Frequently asked questions

Where can I buy 003H6402?
003H6402 can be ordered from cballast.com as a Danfoss catalogue item: request a quotation on this page or email sales@cballast.com, and the order ships worldwide.
What is the manufacturer part number for this Danfoss product?
The manufacturer part number is 003H6402.
What is the HS code for 003H6402?
The customs tariff (HS) code for 003H6402 is 8481.80.
Who manufactures 003H6402?
003H6402 is a Danfoss product in the HVAC & Refrigeration range.
Is a datasheet available for 003H6402?
Yes — the 003H6402 datasheet can be viewed and downloaded on this page.
What is the minimum order quantity for 003H6402?
The minimum order quantity is 1.
Is 003H6402 available?
Yes — 003H6402 is available to order: fulfilment is from supplier stock in cBallast's European network, dispatched directly from the warehouse to the customer, with the exact lead time stated in the quotation (reply within 24 hours).