Bürkert Conductivity Meter, ELEMENT Design
Pricing
Request a quote
We reply within 24 hours
Product Description
Bürkert Type 8222 The Bürkert conductivity meter Type 8222 is designed for measuring the conductivity of liquids. The sensor element comprises a two-electrode cell and a Pt1000 temperature probe. The sensor itself is available with three different cell constants C. These are made of stainless steel for sensors with a constant C of 0.01 or 0.1 cm- 1 and of graphite for sensors with a constant C of 1.0 cm- 1. Thus, due to the measuring device’s design, Bürkert has simplified installation and maintenance work. The Type 8222 device is available in two variants. The first one, the so-called ELEMENT standard is proposed either with three adjustable outputs (two digital outputs and one analogue output) or with four adjustable outputs (two digital and two analogue) and can be equipped with a display. The display is only required for start-up, configuration (e.g. measuring range, units, calibration, limit values) or as a process value display. The second variant, the so-called ELEMENT neutrino, is a 2-wire device, without display, with a 4.20 mA current output or with a digital communication mode that can communicate either via IO-Link or in büS (Bürkert system bus based on CANopen). Both variants are available with a G 1½" union nut for installation in an adapter with a G 1½" external thread sensor connection that is connected to the process. The ELEMENT neutrino variant is also available with a G ¾" external thread for screwing into an adapter with a G ¾" internal thread sensor connection. The Type 8222 device converts the measurement signal and calculates the output signals, which are provided via one or two M12 plug connections in the ELEMENT standard variant or via an M12 plug connection in the ELEMENT neutrino variant or on a terminal strip via a cable gland. The device in the ELEMENT standard variant shows different values in different measuring units (if a display is installed).
Technical Specifications
- HS code
- 9032.89
- Medium temperature
- -20–100 °C
- Probe holder
- PVDF, stainless steel 1.4571 (316Ti)
- Electrode
- For cell constant: • C = 0.01 cm- 1: stainless steel 1.4571 (316Ti) • C= 0.1 cm- 1: stainless steel 1.4571 (316Ti) • C = 1 cm- 1: graphite
- Compatibility
- With any pipe which is fitted with Bürkert S022 adapter. See data sheet Type S022 for more information.
- Pipe diameter
- DN 32...DN 110 (DN 06...DN 25 under specific conditions, i.e. when using reducers)
- Probe
- With cell constant • C = 0.01 cm- 1 • C= 0.1 cm- 1 • C = 1 cm- 1
- Temperature sensor
- Pt1000 integrated within the probe holder
- Conductivity measurement
- 0.05 µS/cm...10 mS/cm
- Temperature measurement
- 20...+ 100 °C (- 4...+ 212 °F)
- Measurement deviation
- ± 3 % of measured value
- Measuring range resolution
- 1 nS/cm
- Power source (not supplied)
- Limited power source according to UL/EN 62368‑1 standards or limited energy circuit according to UL/ EN 61010‑1 paragraph 9.4
- DC reverse polarity protection
- Yes
- Overvoltage protection
- Yes
- Fluid temperature
- Device with • G 1½ PVC union nut connection: 0...+ 50 °C (+ 32...+ 122 °F) • G 1½ PVDF union nut connection (on request for ELEMENT neutrino variant): - 20...+ 100 °C (- 4...+...
- Process connection
- G 1½ internal thread for use with Type S022 adapter See data sheet Type S022 for more information.
- North America (USA/Canada)
- UL Recognized for the USA and Canada
- Ambient temperature
- Operation and storage: - 10...+ 60 °C (+ 14...+ 140 °F)
- Relative air humidity
- ≤ 85 %, without condensation
- Height above sea level
- Max. 2000 m
- Operating condition
- Continuous
- Equipment mobility
- Fixed
- Application range
- Indoor and outdoor Protect the device against electromagnetic interference, ultraviolet rays and, when installed outdoors, against the effects of climatic conditions.
- Installation category
- Category I according to UL/EN 61010‑1
- Pollution degree
- Degree 2 according to UL/EN 61010‑1
- Cover
- Polycarbonate (PC), transparent (opaque on request)
- Housing
- Stainless steel 1.4404 (316L), PPS
Standards & Compliance
- HS Code
- 9032.89
Cross References
- Burkert 8222
- Buerkert 8222
- Bürkert 8222
- Type 8222
- Burkert Type 8222
Product Documentation
More from Bürkert

Bürkert
Bürkert Chlorine Sensor
Type 8232

Bürkert
Bürkert Pressure Transmitter - OEM
Type 8314

Bürkert
Bürkert PWM Control Electronics for Electromagnetic Proportional Valves
Type 8605

Bürkert
Bürkert Pneumatic Control Cabinet Solutions for Hygienic Process Environments
Type 8614

Bürkert
Bürkert AirLINE SP – Electropneumatic Automation System
Type 8647

Bürkert
Bürkert Pneumatic Control Unit for Decentralised Automation of Process Valves ELEMENT Type 8690

Bürkert
Bürkert Control Head for Decentralised Automation of ELEMENT Process Valves Type 8695

Bürkert
Bürkert Mass Flow Controller (MFC)/mass Flowmeter (MFM) for Gases Type 8741
Catalogue entry last verified: 2026-08-29. A manufacturer datasheet is attached to this entry — confirm application-critical values against it.
Frequently asked questions
- Where can I buy Type 8222?
- Type 8222 can be ordered from cballast.com as a Bürkert catalogue item: request a quotation on this page or email sales@cballast.com, and the order ships worldwide.
- What is the manufacturer part number for this Bürkert product?
- The manufacturer part number is Type 8222.
- What is the HS code for Type 8222?
- The customs tariff (HS) code for Type 8222 is 9032.89.
- Who manufactures Type 8222?
- Type 8222 is a Bürkert product in the Sensors & Instrumentation range.
- Is a datasheet available for Type 8222?
- Yes — the Type 8222 datasheet can be viewed and downloaded on this page.
- What is the minimum order quantity for Type 8222?
- The minimum order quantity is 1.
- Is Type 8222 available?
- Yes — Type 8222 is available to order: fulfilment is from supplier stock in cBallast's European network, dispatched directly from the warehouse to the customer, with the exact lead time stated in the quotation (reply within 24 hours).