Siemens logo

Image not available for this product

Siemens

Siemens SIMATIC ET 200SP AI 4XI 2-Wire 4...20MA HART

Part number6ES7134-6TD00-0CA1EAN / GTIN4047623404972HS code8544.42
Control & Automation
PLCs & Industrial Networking
MOQ:1

Pricing

Request a quote

We reply within 24 hours

Product Description

Siemens 6ES7134-6TD00-0CA1 — SIMATIC S7 automation module. Compact controller or expansion module for the S7-1200 or S7-1500 PLC platform. SIMATIC ET 200SP, Analog HART input module, AI 4XI 2-Wire HART High feature.

Technical Specifications

Manufacturer part number (MPN)
6ES7134-6TD00-0CA1
EAN / GTIN
4047623404972
HS code
8544.42
Sales unit
pcs
Product type designation
AI 4xI 2-wire HART
Firmware version
V1.0
Firmware version — FW update possible
Yes
Usable BaseUnits
BU type A0, A1
Color code for module-specific color-coded label
CC03
Product function — I&M data
Yes; I&M0 to I&M3
Engineering with — STEP 7 TIA Portal configurable/integrated from version
V13 SP1
Engineering with — STEP 7 configurable/integrated from version
V5.5 SP4 and higher
Engineering with — PCS 7 configurable/integrated from version
V8.1 SP1
Engineering with — PROFIBUS from GSD version/GSD revision
GSD Revision 5
Engineering with — PROFINET from GSD version/GSD revision
GSDML V2.3
Rated value (DC)
24 V
Permissible range, lower limit (DC)
19.2 V
Permissible range, upper limit (DC)
28.8 V
Reverse polarity protection
Yes
Current consumption, max.
25 mA; without sensor supply
24 V encoder supply — Short-circuit protection
Yes
24 V encoder supply — Output current, max.
20 mA; max. 50 mA per channel for a duration < 10 s
Power loss, typ.
0.65 W; without sensor supply
Address space per module — Address space per module, max.
8 byte; + 1 byte for QI information
Address space per module — Address space per module with HART, max.
28 byte; + 1 byte for QI information
Automatic encoding — Type of mechanical coding element
Type A
Number of analog inputs
4; Differential inputs
Number of analog inputs — For current measurement
4
Permissible input current for current input (destruction limit), max.
50 mA
Input ranges (rated values), currents — 0 to 20 mA
No
Input ranges (rated values), currents — -20 mA to +20 mA
No
Input ranges (rated values), currents — 4 mA to 20 mA
Yes; 15 bit + sign
Input ranges (rated values), currents — Input resistance (4 mA to 20 mA)
280 Ω; + approx. 0.35 V diode forward voltage
Cable length — shielded, max.
800 m
Measurement principle
integrating (Sigma-Delta)
Integration and conversion time/resolution per channel — Resolution with overrange (bit including sign), max.
16 bit
Integration and conversion time/resolution per channel — Integration time, parameterizable
Yes; channel by channel
Smoothing of measured values — Number of smoothing levels
4; None; 4/8/16 times
Connection of signal encoders — for voltage measurement
No
Connection of signal encoders — for current measurement as 2-wire transducer
Yes
Linearity error (relative to input range), (+/-)
0.01 %
Temperature error (relative to input range), (+/-)
0.005 %/K
Crosstalk between the inputs, min.
60 dB
Repeat accuracy in steady state at 25 °C (relative to input range), (+/-)
0.05 %
Operational error limit in overall temperature range — Current, relative to input range, (+/-)
0.5 %
Basic error limit (operational limit at 25 °C) — Current, relative to input range, (+/-)
0.3 %
Diagnoses — Monitoring the supply voltage
Yes
Diagnoses — Wire break
Yes; channel by channel
Diagnoses — Short-circuit
Yes; Channel-by-channel, short-circuit of the encoder supply to ground or of an input to the encoder supply
Diagnoses — Overflow/Underflow
Yes; channel by channel
Diagnostics indication LED — Monitoring of the supply voltage (PWR-LED)
Yes; green PWR LED
Diagnostics indication LED — Channel status display
Yes; green LED
Diagnostics indication LED — for channel diagnostics
Yes; red LED
Potential separation channels — between the channels and the power supply of the electronics
No
Isolation tested with
707 V DC (type test)
Ambient temperature during operation — horizontal installation, min.
-30 °C
Ambient temperature during operation — horizontal installation, max.
60 °C
Ambient temperature during operation — vertical installation, min.
-30 °C
Ambient temperature during operation — vertical installation, max.
50 °C
Altitude during operation relating to sea level — Installation altitude above sea level, max.
5 000 m; restrictions for installation altitudes > 2 000 m, see ET 200SP system manual
Dimensions — Width
15 mm
Dimensions — Height
73 mm
Dimensions — Depth
58 mm
Weight, approx.
31 g

Standards & Compliance

HS Code
8544.42

Cross References

  • EAN 4047623404972
  • SAP 1000721581
  • Code 8342176

Product Documentation

Document preview: Siemens 6ES7134-6TD00-0CA1 — OEM Datasheet

Catalogue entry last verified: 2026-09-30. A manufacturer datasheet is attached to this entry — confirm application-critical values against it.

Frequently asked questions

Where can I buy 6ES7134-6TD00-0CA1?
6ES7134-6TD00-0CA1 can be ordered from cballast.com as a Siemens catalogue item: request a quotation on this page or email sales@cballast.com, and the order ships worldwide.
What is the manufacturer part number for this Siemens product?
The manufacturer part number is 6ES7134-6TD00-0CA1.
What is the HS code for 6ES7134-6TD00-0CA1?
The customs tariff (HS) code for 6ES7134-6TD00-0CA1 is 8544.42.
Who manufactures 6ES7134-6TD00-0CA1?
6ES7134-6TD00-0CA1 is a Siemens product in the Control & Automation range.
Is a datasheet available for 6ES7134-6TD00-0CA1?
Yes — the 6ES7134-6TD00-0CA1 datasheet can be viewed and downloaded on this page.
What is the minimum order quantity for 6ES7134-6TD00-0CA1?
The minimum order quantity is 1.
Is 6ES7134-6TD00-0CA1 available?
Yes — 6ES7134-6TD00-0CA1 is available to order: fulfilment is from supplier stock in cBallast's European network, dispatched directly from the warehouse to the customer, with the exact lead time stated in the quotation (reply within 24 hours).