Schneider LC1K Contactor - TeSys K, 3P, 400V 3389110490350
Schneider Electric

Schneider LC1K Contactor - TeSys K, 3P, 400V 3389110490350

Part numberLC1K0910V7EAN / GTIN3389110490350HS code8536.49
MOQ:1

Pricing

Request a quote

We reply within 24 hours

Product Description

Schneider LC1K Contactor. Contactors and thermal relays motor control (Electrical Engineering / Components for panels and boxes). Principal data: series TeSys K, number of poles 3P, voltage 400 V. Supplied under manufacturer part number LC1K0910V7, EAN 3389110490350, HS code 8536.49, country of origin France.

Technical Specifications

Product type
Contactors and thermal relays motor control Product group: Components for panels and boxes Series: TeSys K Number of poles: 3P Voltage: 400 V Carbon footprint (EPD): 1.0179 kg CO2e per pcs Country of origin: France Customs tariff code (EU CN): 85364900 HS code: 8536.49 Manufacturer part number: LC1K0910V7 Range: TeSys Product or component type: Contactor Device application: Control Contactor application: Resistive load; Motor control Utilisation category: AC-3; AC-3e; AC-1; AC-4 Poles description: 3P power pole contact composition: 3 NO [Ue] rated operational voltage: Power circuit: <= 690 V AC <= 400 Hz; Signalling circuit: <= 690 V AC <= 400 Hz [Ie] rated operational current: 9 A (at <60 °C) at <= 440 V AC AC-3 for power circuit; 9 A (at <60 °C) at <= 440 V AC AC-3e for power circuit; 20 A (at <60 °C) at <= 690 V AC AC-1 for power circuit Control circuit type: AC at 50/60 Hz [Uc] control circuit voltage: 400 V AC 50/60 Hz Motor power kW: 2.2 kW at 220...230 V AC 50/60 Hz AC-3; 4 kW at 380...415 V AC 50/60 Hz AC-3; 4 kW at 440/690 V AC 50/60 Hz AC-3; 2.2 kW at 220...230 V AC 50/60 Hz AC-3e; 4 kW at 380...415 V AC 50/60 Hz AC-3e; 4 kW at 440/690 V AC 50/60 Hz AC-3e; 2.2 kW at 220...230 V AC 50/60 Hz AC-4; 4 kW at 380...415 V AC 50/60 Hz AC-4; 4 kW at 440/690 V AC 50/60 Hz AC-4 Auxiliary contact composition: 1 NO [Uimp] rated impulse withstand voltage: 8 kV Overvoltage category: III [Ith] conventional free air thermal current: 20 A (at 60 °C) for power circuit; 10 A (at 50 °C) for signalling circuit Irms rated making capacity: 110 A AC for power circuit conforming to IEC 60947; 110 A AC for signalling circuit conforming to IEC 60947 Rated breaking capacity: 110 A at 220...230 V conforming to IEC 60947; 110 A at 380...400 V conforming to IEC 60947; 110 A at 415 V conforming to IEC 60947; 110 A at 440 V conforming to IEC 60947; 80 A at 500 V conforming to IEC 60947; 70 A at 660...690 V conforming to IEC 60947 [Icw] rated short-time withstand current: 90 A 50 °C - 1 s for power circuit; 85 A 50 °C - 5 s for power circuit; 80 A 50 °C - 10 s for power circuit; 60 A 50 °C - 30 s for power circuit; 45 A 50 °C - 1 min for power circuit; 40 A 50 °C - 3 min for power circuit; 20 A 50 °C - >= 15 min for power circuit; 80 A - 1 s for signalling circuit; 90 A - 500 ms for signalling circuit; 110 A - 100 ms for signalling circuit Associated fuse rating: 25 A gG at <= 440 V for power circuit; 25 A aM for power circuit; 10 A gG for signalling circuit conforming to IEC 60947; 10 A gG for signalling circuit conforming to VDE 0660 Average impedance: 3 mOhm - Ith 20 A 50 Hz for power circuit Insulation resistance: > 10 MOhm for signalling circuit Inrush power in VA: 30 VA (at 20 °C) Hold-in power consumption in VA: 4.5 VA (at 20 °C) Heat dissipation: 1.3 W Control circuit voltage limits: Operational: 0.8...1.15 Uc (at = 0.20 Uc (at <50 °C) Connections - terminals: Screw clamp terminals 1 cable(s) 1.5…4 mm²solid; Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable end; Screw clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable end; Screw clamp terminals 2 cable(s) 1.5…4 mm²solid; Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end; Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end Maximum operating rate: 3600 cyc/h Coil technology: Without built-in suppressor module Auxiliary contacts type: type instantaneous 1 NO Signalling circuit frequency: <= 400 Hz minimum switching current: 5 mA for signalling circuit minimum switching voltage: 17 V for signalling circuit Operating time: 10...20 ms coil de-energisation and NO opening; 10...20 ms coil energisation and NO closing Safety reliability level: B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 Non overlap distance: 0.5 mm Mechanical durability: 10 Mcycles Electrical durability: 1.3 Mcycles 9 A AC-3 at Ue <= 440 V; 1.3 Mcycles 9 A AC-3e at Ue <= 440 V; 0.16 Mcycles 20 A AC-1 at Ue <= 690 V; 0.02 Mcycles 54 A AC-4 at Ue <= 440 V Mechanical robustness: Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27; Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27; Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27; Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27; Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27; Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27; Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6; Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Height: 58 mm Width: 45 mm Depth: 57 mm Standards: EN/IEC 60947-4-1; GB/T 14048.4; UL 60947-4-1; CSA C22.2 No 60947-4-1; JIS C8201-4-1; IEC 60335-1:Clause 30.2; IEC 60335-2-40:Annex JJ; UL 60335-2-40:Annex JJ Product certifications: CB Scheme; CCC; UL; CSA; EAC; CE; UKCA Protective treatment: TC conforming to IEC 60068; TC conforming to DIN 50016 Operating altitude: 2000 m without derating Flame retardance: V1 conforming to UL 94; Requirement 2 conforming to NF F 16-101; Requirement 2 conforming to NF F 16-102 Warranty (in months): 18 EAN: 3389110490350

Standards & Compliance

HS Code
8536.49

Cross References

  • EAN 3389110490350
  • MPN LC1K0910V7

Product Documentation

Document preview: Declaration

Catalogue entry last verified: 2026-09-29. A manufacturer datasheet is attached to this entry — confirm application-critical values against it.

Frequently asked questions

Where can I buy LC1K0910V7?
LC1K0910V7 can be ordered from cballast.com as a Schneider Electric catalogue item: request a quotation on this page or email sales@cballast.com, and the order ships worldwide.
What is the manufacturer part number for this Schneider Electric product?
The manufacturer part number is LC1K0910V7.
What is the HS code for LC1K0910V7?
The customs tariff (HS) code for LC1K0910V7 is 8536.49.
Who manufactures LC1K0910V7?
LC1K0910V7 is a Schneider Electric product in the Electrical Components range.
Is a datasheet available for LC1K0910V7?
Yes — the LC1K0910V7 datasheet can be viewed and downloaded on this page.
What is the minimum order quantity for LC1K0910V7?
The minimum order quantity is 1.
Is LC1K0910V7 available?
Yes — LC1K0910V7 is available to order: fulfilment is from supplier stock in cBallast's European network, dispatched directly from the warehouse to the customer, with the exact lead time stated in the quotation (reply within 24 hours).