AMP.MET.3-Phase.0 Still. Ø22
Pricing
Request a quote
We reply within 24 hours
Product Description
Schneider Electric K1F003MCH Cam Switch amp.met.3-phase.+0 bottom.
Technical Specifications
- Manufacturer part number (MPN)
- K1F003MCH
- EAN / GTIN
- 3389110979176
- Sales unit
- pcs
- Package quantity
- 8 pcs
- Diameter
- 22 mm
- Range of product
- Harmony K
- Product or component type
- Complete cam switch
- Component name
- K1
- [Ith] conventional free air thermal current
- 12 A
- Product mounting
- Front mounting
- fixing mode
- Ø 22 mm hole
- Cam switch head type
- With front plate 45 x 45 mm
- Type of operator
- Black handle, length = 35 mm
- Rotary handle padlocking
- Without
- Presentation of legend
- With metallic legend, 0 - L1 - L2 - L3 black marking
- Cam switch function
- Ammeter switch
- Return
- Without
- Type of measurement
- For 3 circuits
- Off position
- With Off position
- Switching positions
- Right: 0° - 90° - 180° - 270°
- IP degree of protection
- IP65 conforming to IEC 529; IP65 conforming to NF C 20-010
- Switching angle
- 90 °
- [Ui] rated insulation voltage
- 690 V (pollution degree 3) conforming to IEC 60947-1
- [Ithe] conventional enclosed thermal current
- 10 A
- Rated operational power in W
- 10500 W AC-21, 500...660 V 3 phases conforming to IEC 60947-3; 1100 W AC-3, 230 V 3 phases conforming to IEC 60947-3; 1500 W AC-23A, 230 V 3 phases conforming to IEC 60947-3; 1500 W AC-3, 400 V 1 phase conforming to IEC 60947-3; 1500 W AC-3, 400 V 3 phases conforming to IEC 60947-3; 1500 W AC-3, 500 V 3 phases conforming to IEC 60947-3; 1500 W AC-3, 690 V 3 phases conforming to IEC 60947-3; 2200 W AC-23A, 400 V 3 phases conforming to IEC 60947-3; 2200 W AC-23A, 500 V 3 phases conforming to IEC 60947-3; 2200 W AC-23A, 690 V 3 phases conforming to IEC 60947-3; 4800 W AC-21, 230 V 3 phases conforming to IEC 60947-3; 600 W AC-3, 230 V 1 phase conforming to IEC 60947-3; 8300 W AC-21, 400 V 3 phases conforming to IEC 60947-3
- [Ie] rated operational current AC
- 1 A at 500 V AC-15 conforming to IEC 60947-5-1; 2 A at 400 V AC-15 conforming to IEC 60947-5-1; 3 A at 230 V AC-15 conforming to IEC 60947-5-1; 1.8 A at 690 V AC-3 3 phases conforming to IEC 60947-3; 2.8 A at 500 V AC-3 3 phases conforming to IEC 60947-3; 2.8 A at 690 V AC-23A 3 phases conforming to IEC 60947-3; 3.3 A at 400 V AC-3 3 phases conforming to IEC 60947-3; 3.8 A at 500 V AC-23A 3 phases conforming to IEC 60947-3; 4.6 A at 230 V AC-3 3 phases conforming to IEC 60947-3; 4.8 A at 400 V AC-23A 3 phases conforming to IEC 60947-3; 5.6 A at 230 V AC-23A 3 phases conforming to IEC 60947-3
- Electrical durability
- 1000000 cycles AC-15; 1000000 cycles AC-21; 500000 cycles AC-23; 500000 cycles AC-3
- Maximum operating rate
- 2.5 cyc/mn AC-21; 2.5 cyc/mn AC-23; 2.5 cyc/mn AC-3; 8.333 cyc/mn AC-15
- Short-circuit current
- 10000 A
- Short-circuit protection
- 16 A cartridge fuse, type gG
- [Uimp] rated impulse withstand voltage
- 4 kV in isolating function; 6 kV conforming to IEC 60947-1
- Contact operation
- Slow-break
- positive opening
- With
- Electrical connection
- Captive screw clamp terminals flexible, clamping capacity: 2 x 1.5 mm²; Captive screw clamp terminals solid, clamping capacity: 1 x 2.5 mm²
- Mechanical durability
- 1000000 cycles
- CAD overall width
- 45 mm
- CAD overall height
- 50 mm
- CAD overall depth
- 69 mm
- Product weight
- 0.19 kg
- Standards
- CENELEC EN 50013; EN/IEC 60947-3 for power circuit; EN/IEC 60947-5-1 for control circuit
- Product certifications
- CSA 240 V 1 hp 1 phase; CSA 240 V 3 hp 3 phases 2 pole(s); UL 240 V 1 hp 3 phases; UL 240 V 0.33 hp 1 phase 2 pole(s)
- Protective treatment
- TC
- Ambient air temperature for operation
- -25…55 °C
- Ambient air temperature for storage
- -40…70 °C
- Shock resistance
- 30 gn conforming to IEC 68-2-27
- Vibration resistance
- 5 gn conforming to IEC 68-2-6 (f = 10…150 Hz)
- Electrical shock protection class
- Class II conforming to IEC 536; Class II conforming to NF C 20-030
- Number of Units in Package 1
- 1
- Number of Units in Package 2
- 8
- Country of origin
- CZ
- Warranty (in months)
- 18
- With zero (off) position
- Yes
- Device construction
- Front installation
- Suitable for distribution board
- No
- With control element
- Yes
- Degree of protection (IP)
- IP65
Standards & Compliance
- HS Code
- 8536.50
Cross References
- EAN 3389110979176
- SAP 1000253070
- Code 8107920
Product Documentation
More from Schneider Electric

Schneider Electric
Schneider Electric Plastic window with hinged transparent cover. L78XW130XD15MM. NSYVA276M

Schneider Electric
Schneider Electric Thermal magnetic circuit breaker, TeSys GB2, 1P+N, 1 A, Icu 50 kA@240 V GB2CD06

Schneider Electric
Schneider Electric LC2D32EHE TeSys Deca Reversing Contactor, 3-Pole 32 A AC-3, 48–130 V AC/DC Coil

Schneider Electric
Schneider Electric Push button flush mounted, Harmony XB4, metal, green, 30mm, spring return, marked I, 1NO XB4FA3311

Schneider Electric
DM over/under frekvensvern MTZ
LV850013

Schneider Electric
Schneider Electric APC NetShelter CX, Mini, Dust Filter Pack, 38U, Includes 2 Small and 2 Large Filters, Black AR4702

Schneider Electric
ACTI 9 IC40N 3P C 13A MCB
A9P54313

Schneider Electric
Schneider Electric TeSys LR2D3555 Thermal Overload Relay 30-40 A Class 20
Technical guides
Catalogue entry last verified: 2026-09-30. A manufacturer datasheet is attached to this entry — confirm application-critical values against it.
Frequently asked questions
- Where can I buy K1F003MCH?
- K1F003MCH can be ordered from cballast.com as a Schneider Electric catalogue item: request a quotation on this page or email sales@cballast.com, and the order ships worldwide.
- What is the manufacturer part number for this Schneider Electric product?
- The manufacturer part number is K1F003MCH.
- What is the HS code for K1F003MCH?
- The customs tariff (HS) code for K1F003MCH is 8536.50.
- Who manufactures K1F003MCH?
- K1F003MCH is a Schneider Electric product in the SC000912 range.
- Is a datasheet available for K1F003MCH?
- Yes — the K1F003MCH datasheet can be viewed and downloaded on this page.
- What is the minimum order quantity for K1F003MCH?
- The minimum order quantity is 1.
- Is K1F003MCH available?
- Yes — K1F003MCH is available to order: fulfilment is from supplier stock in cBallast's European network, dispatched directly from the warehouse to the customer, with the exact lead time stated in the quotation (reply within 24 hours).