Murrelektronik logo

Image not available for this product

Murrelektronik

M12 male 0° / M12 female 0° A-cod. PUR AWG24+22 shielded vt UL/CSA+drag ch. 7.5M

Part number7000-40531-8030750EAN / GTIN4048879164894HS code8544.42
Cables & Wiring
Sensor Cables
MOQ:1

Pricing

Request a quote

We reply within 24 hours

Product Description

Murrelektronik 7000-40531-8030750 Devicenet cable Han/female, PUR cable, shielded with UL/CSA, 7,5m.

Technical Specifications

Manufacturer part number (MPN)
7000-40531-8030750
Model designation
MSBL0-A-U803_7.5
EAN / GTIN
4048879164894
HS code
8544.42
EU customs tariff number
85444290
US customs tariff number
8544429090
Weight
0.508 kg
Country of origin
CZ
Sales unit
pcs
Cable length
7.50 m
Side 1 - Family construction form
M12
Side 1 - No. of poles
5
Side 1 - Coding
A
Side 1 - Gender
male
Side 1 - Mounting method
inserted, screwed
Side 1 - Threaded hole
M12 x 1
Side 1 - Tightening torque
0.6 Nm
Side 1 - Width across flats
SW13
Side 1 - Cable outlet
straight
Side 1 - Material
PUR
Side 1 - Degree of protection (EN IEC 60529)
IP67, IP66K, IP65
Side 2 - Family construction form
M12
Side 2 - No. of poles
5
Side 2 - Coding
A
Side 2 - Gender
female
Side 2 - Mounting method
inserted, screwed
Side 2 - Threaded hole
M12 x 1
Side 2 - Tightening torque
0.6 Nm
Side 2 - Width across flats
SW13
Side 2 - Cable outlet
straight
Side 2 - Material
PUR
Side 2 - Degree of protection (EN IEC 60529)
IP67, IP66K, IP65
Electrical data | Supply - Operating voltage AC max.
60 V
Electrical data | Supply - Operating voltage DC max.
60 V
Supply - Current operating per contact max.
4 A
Supply - Operating voltage AC (UL-listed)
30 V
Supply - Operating voltage DC (UL-listed)
30 V
Diagnostics - Status indication LED
No
Installation | Connection - Mounting set
M12 x 1
Electrical - Degree of protection (EN IEC 60529)
IP67, IP66K, IP65
Electrical - Additional condition protection degree
inserted, screwed
Device protection | Electrical - Pollution Degree
3
Device protection | Electrical - Rated surge voltage
1.5 kV
Electrical - Material group (IEC 60664-1)
I
Mechanical data - Contour for corrugated hose
without
Mechanical data | Material data - Screw connection
Zinc die-casting
Mechanical data | Material data - Coating of fitting
nickel plated
Mechanical data | Material data - Locking material
Zinc die-casting
Mechanical data | Material data - Coating locking
Nickeled
Mechanical data | Material data - Gasket
FKM
Mechanical data | Mounting data - Mounting method
inserted, screwed, Shaking protection
Climatic - Operating temperature min.
-30 °C
Climatic - Operating temperature max.
85 °C
Climatic - Additional condition temperature range
depending on cable quality
Important installation notes - Note on bending radius
Attention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces.
Important installation notes - Note on strain relief
Protect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties.
Conformity - Product standard
EN IEC 61076-2-101 (M12)
General data | Cable - Cable identification
803
General data | Cable - Function cable
Hybrid, Data, Power
General data | Cable - Cable weigth
57.38 g/m
General data | Cable - UL AWM Style
20549 / 10578
Structure | Cable - Stranding
2 × 2 wires stranded
Structure | Cable - Stranding (type 2)
1 × 2 stranding combinations stranded
Structure | Cable - Cable shielding (type)
copper braid, tinned
Structure | Cable - Cable shielding (coverage)
65 %
Structure | Cable - Pair shielding (type)
Metal foil
Structure | Cable - Banding
Foil
Structure | Cable - Drain wire (cross-section)
22 AWG
Structure | Cable - Wire arrangement
(WH, BU), (BK, RD)
Structure | Cable - Shield
shielded
Structure | Cable - Cable type
CAN DeviceNet
Wire data | Cable - Electrical function wire
Data
Wire data | Cable - Material wire insulation
PE
Wire data | Cable - Amount wires
2
Wire data | Cable - Outer diameter insulation
2.1 mm ± 0.05 mm
Wire data | Cable - Conductor crosssection (wire)
24 AWG
Wire data | Cable - Material conductor wire
copper stranded wire, tinned
Wire data | Cable - Core construction (wire)
19 x 36 AWG
Wire data | Cable - Ingredient freeness wire insulation
lead-free, CFC-free, halogen-free
Wire data | Cable - Electrical function wire (type 2)
Power
Wire data | Cable - Material wire insulation (type 2)
PE
Wire data | Cable - Amount wires (type 2)
2
Cable - Outer diameter wire insulation (type 2)
1.5 mm ± 0.05 mm
Wire data | Cable - Conductor crosssection (wire type 2)
22 AWG
Wire data | Cable - Material conductor wire (type 2)
copper stranded wire, tinned
Wire data | Cable - Core construction (wire type 2)
19 x 34 AWG
Cable - Ingredient freeness wire insulation (type 2)
lead-free, CFC-free, halogen-free
Jacket data | Cable - Material jacket
PUR
Jacket data | Cable - Outer-diameter (jacket)
6.9 mm ± 5 %
Jacket data | Cable - Jacket Color
violet / RAL 4001
Jacket data | Cable - Freedom from ingredients (jacket)
lead-free, CFC-free, halogen-free
Shield | Cable - Cable shielding (type)
copper braid, tinned
Shield | Cable - Cable shielding (coverage)
65 %
Shield | Cable - Pair shielding (type)
Metal foil
Electrical data | Cable - Conductor resistance (wire)
94.2 Ω/km @ 20 °C
Cable - Conductor resistance (wire type 2)
59.4 Ω/km @ 20 °C
Electrical data | Cable - Nominal voltage max.
300 V
Electrical data | Cable - Withstand voltage (wire - wire)
2 kV @ 60 s
Cable - Withstand voltage (wire - shield)
2 kV @ 60 s
Cable - Current load capacity max. (wire)
3 A
Cable - Current load capacity max. Wire (type 2)
6 A
Electrical data | Cable - Current load capacity (standard)
to DIN VDE 0298-4
Electrical data | Cable - Electric capacitance
40.000 pF/km
Electrical data | Cable - Isolation resistance
5 GΩ × km
Electrical data | Cable - Characteristic impedance
120 Ω ± 10 % @ 10 MHz
Temperature range | Cable - Operating temperature (static)
-40 °C … 80 °C
Cable - Operating temperature (dynamic)
-30 °C … 70 °C
Resistances | Cable - Flame resistance
IEC 60332-1-2, UL 1581 § 1060, UL 1581 § 1090, UL 1581 § 1100
Resistances | Cable - Oil resistance
IEC 60811-404, IRM 902
Resistances | Cable - Ozone resistance
IEC 60811-403, EN 50396
Resistances | Cable - UV resistance
UL 1581 § 1200 @ 300 h
Resistances | Cable - Other resistances
good resistance to saturated hydrocarbons (diesel, kerosene, petrol ether), resistant to microbes, MUD-resistant (NEK 606)
Resistances | Cable - Notes
application-related testing
Installation | Cable - Bending radius (fixed)
6 × Outer diameter
Installation | Cable - Bending radius (dynamic)
10 × Outer diameter
Installation | Cable - No. of bending cycles (C-track)
1 Mio. @ 25 °C
Installation | Cable - Traversing distance (C-track)
5 m @ 25 °C
Installation | Cable - Travel speed (C-track)
3 m/s @ 25 °C
Installation | Cable - Acceleration (C-track)
5 m/s² @ 25 °C
ETIM-5.0
EC001855

Standards & Compliance

HS Code
8544.42

Cross References

  • EAN 4048879164894
  • SAP 1000434566
  • Code 8939741

Catalogue entry last verified: 2026-09-30. A manufacturer datasheet is attached to this entry — confirm application-critical values against it.

Frequently asked questions

Where can I buy 7000-40531-8030750?
7000-40531-8030750 can be ordered from cballast.com as a Murrelektronik catalogue item: request a quotation on this page or email sales@cballast.com, and the order ships worldwide.
What is the manufacturer part number for this Murrelektronik product?
The manufacturer part number is 7000-40531-8030750.
What is the HS code for 7000-40531-8030750?
The customs tariff (HS) code for 7000-40531-8030750 is 8544.42.
Who manufactures 7000-40531-8030750?
7000-40531-8030750 is a Murrelektronik product in the Cables & Wiring range.
Is a datasheet available for 7000-40531-8030750?
Yes — the 7000-40531-8030750 datasheet can be viewed and downloaded on this page.
What is the minimum order quantity for 7000-40531-8030750?
The minimum order quantity is 1.
Is 7000-40531-8030750 available?
Yes — 7000-40531-8030750 is available to order: fulfilment is from supplier stock in cBallast's European network, dispatched directly from the warehouse to the customer, with the exact lead time stated in the quotation (reply within 24 hours).