Image not available for this product
M12 male 0° / M12 female 0° A-cod. PUR AWG24+22 shielded vt UL/CSA+drag ch. 7.5M
Pricing
Request a quote
We reply within 24 hours
Product Description
Murrelektronik 7000-40531-8030750 Devicenet cable Han/female, PUR cable, shielded with UL/CSA, 7,5m.
Technical Specifications
- Manufacturer part number (MPN)
- 7000-40531-8030750
- Model designation
- MSBL0-A-U803_7.5
- EAN / GTIN
- 4048879164894
- HS code
- 8544.42
- EU customs tariff number
- 85444290
- US customs tariff number
- 8544429090
- Weight
- 0.508 kg
- Country of origin
- CZ
- Sales unit
- pcs
- Cable length
- 7.50 m
- Side 1 - Family construction form
- M12
- Side 1 - No. of poles
- 5
- Side 1 - Coding
- A
- Side 1 - Gender
- male
- Side 1 - Mounting method
- inserted, screwed
- Side 1 - Threaded hole
- M12 x 1
- Side 1 - Tightening torque
- 0.6 Nm
- Side 1 - Width across flats
- SW13
- Side 1 - Cable outlet
- straight
- Side 1 - Material
- PUR
- Side 1 - Degree of protection (EN IEC 60529)
- IP67, IP66K, IP65
- Side 2 - Family construction form
- M12
- Side 2 - No. of poles
- 5
- Side 2 - Coding
- A
- Side 2 - Gender
- female
- Side 2 - Mounting method
- inserted, screwed
- Side 2 - Threaded hole
- M12 x 1
- Side 2 - Tightening torque
- 0.6 Nm
- Side 2 - Width across flats
- SW13
- Side 2 - Cable outlet
- straight
- Side 2 - Material
- PUR
- Side 2 - Degree of protection (EN IEC 60529)
- IP67, IP66K, IP65
- Electrical data | Supply - Operating voltage AC max.
- 60 V
- Electrical data | Supply - Operating voltage DC max.
- 60 V
- Supply - Current operating per contact max.
- 4 A
- Supply - Operating voltage AC (UL-listed)
- 30 V
- Supply - Operating voltage DC (UL-listed)
- 30 V
- Diagnostics - Status indication LED
- No
- Installation | Connection - Mounting set
- M12 x 1
- Electrical - Degree of protection (EN IEC 60529)
- IP67, IP66K, IP65
- Electrical - Additional condition protection degree
- inserted, screwed
- Device protection | Electrical - Pollution Degree
- 3
- Device protection | Electrical - Rated surge voltage
- 1.5 kV
- Electrical - Material group (IEC 60664-1)
- I
- Mechanical data - Contour for corrugated hose
- without
- Mechanical data | Material data - Screw connection
- Zinc die-casting
- Mechanical data | Material data - Coating of fitting
- nickel plated
- Mechanical data | Material data - Locking material
- Zinc die-casting
- Mechanical data | Material data - Coating locking
- Nickeled
- Mechanical data | Material data - Gasket
- FKM
- Mechanical data | Mounting data - Mounting method
- inserted, screwed, Shaking protection
- Climatic - Operating temperature min.
- -30 °C
- Climatic - Operating temperature max.
- 85 °C
- Climatic - Additional condition temperature range
- depending on cable quality
- Important installation notes - Note on bending radius
- Attention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces.
- Important installation notes - Note on strain relief
- Protect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties.
- Conformity - Product standard
- EN IEC 61076-2-101 (M12)
- General data | Cable - Cable identification
- 803
- General data | Cable - Function cable
- Hybrid, Data, Power
- General data | Cable - Cable weigth
- 57.38 g/m
- General data | Cable - UL AWM Style
- 20549 / 10578
- Structure | Cable - Stranding
- 2 × 2 wires stranded
- Structure | Cable - Stranding (type 2)
- 1 × 2 stranding combinations stranded
- Structure | Cable - Cable shielding (type)
- copper braid, tinned
- Structure | Cable - Cable shielding (coverage)
- 65 %
- Structure | Cable - Pair shielding (type)
- Metal foil
- Structure | Cable - Banding
- Foil
- Structure | Cable - Drain wire (cross-section)
- 22 AWG
- Structure | Cable - Wire arrangement
- (WH, BU), (BK, RD)
- Structure | Cable - Shield
- shielded
- Structure | Cable - Cable type
- CAN DeviceNet
- Wire data | Cable - Electrical function wire
- Data
- Wire data | Cable - Material wire insulation
- PE
- Wire data | Cable - Amount wires
- 2
- Wire data | Cable - Outer diameter insulation
- 2.1 mm ± 0.05 mm
- Wire data | Cable - Conductor crosssection (wire)
- 24 AWG
- Wire data | Cable - Material conductor wire
- copper stranded wire, tinned
- Wire data | Cable - Core construction (wire)
- 19 x 36 AWG
- Wire data | Cable - Ingredient freeness wire insulation
- lead-free, CFC-free, halogen-free
- Wire data | Cable - Electrical function wire (type 2)
- Power
- Wire data | Cable - Material wire insulation (type 2)
- PE
- Wire data | Cable - Amount wires (type 2)
- 2
- Cable - Outer diameter wire insulation (type 2)
- 1.5 mm ± 0.05 mm
- Wire data | Cable - Conductor crosssection (wire type 2)
- 22 AWG
- Wire data | Cable - Material conductor wire (type 2)
- copper stranded wire, tinned
- Wire data | Cable - Core construction (wire type 2)
- 19 x 34 AWG
- Cable - Ingredient freeness wire insulation (type 2)
- lead-free, CFC-free, halogen-free
- Jacket data | Cable - Material jacket
- PUR
- Jacket data | Cable - Outer-diameter (jacket)
- 6.9 mm ± 5 %
- Jacket data | Cable - Jacket Color
- violet / RAL 4001
- Jacket data | Cable - Freedom from ingredients (jacket)
- lead-free, CFC-free, halogen-free
- Shield | Cable - Cable shielding (type)
- copper braid, tinned
- Shield | Cable - Cable shielding (coverage)
- 65 %
- Shield | Cable - Pair shielding (type)
- Metal foil
- Electrical data | Cable - Conductor resistance (wire)
- 94.2 Ω/km @ 20 °C
- Cable - Conductor resistance (wire type 2)
- 59.4 Ω/km @ 20 °C
- Electrical data | Cable - Nominal voltage max.
- 300 V
- Electrical data | Cable - Withstand voltage (wire - wire)
- 2 kV @ 60 s
- Cable - Withstand voltage (wire - shield)
- 2 kV @ 60 s
- Cable - Current load capacity max. (wire)
- 3 A
- Cable - Current load capacity max. Wire (type 2)
- 6 A
- Electrical data | Cable - Current load capacity (standard)
- to DIN VDE 0298-4
- Electrical data | Cable - Electric capacitance
- 40.000 pF/km
- Electrical data | Cable - Isolation resistance
- 5 GΩ × km
- Electrical data | Cable - Characteristic impedance
- 120 Ω ± 10 % @ 10 MHz
- Temperature range | Cable - Operating temperature (static)
- -40 °C … 80 °C
- Cable - Operating temperature (dynamic)
- -30 °C … 70 °C
- Resistances | Cable - Flame resistance
- IEC 60332-1-2, UL 1581 § 1060, UL 1581 § 1090, UL 1581 § 1100
- Resistances | Cable - Oil resistance
- IEC 60811-404, IRM 902
- Resistances | Cable - Ozone resistance
- IEC 60811-403, EN 50396
- Resistances | Cable - UV resistance
- UL 1581 § 1200 @ 300 h
- Resistances | Cable - Other resistances
- good resistance to saturated hydrocarbons (diesel, kerosene, petrol ether), resistant to microbes, MUD-resistant (NEK 606)
- Resistances | Cable - Notes
- application-related testing
- Installation | Cable - Bending radius (fixed)
- 6 × Outer diameter
- Installation | Cable - Bending radius (dynamic)
- 10 × Outer diameter
- Installation | Cable - No. of bending cycles (C-track)
- 1 Mio. @ 25 °C
- Installation | Cable - Traversing distance (C-track)
- 5 m @ 25 °C
- Installation | Cable - Travel speed (C-track)
- 3 m/s @ 25 °C
- Installation | Cable - Acceleration (C-track)
- 5 m/s² @ 25 °C
- ETIM-5.0
- EC001855
Standards & Compliance
- HS Code
- 8544.42
Cross References
- EAN 4048879164894
- SAP 1000434566
- Code 8939741
Product Documentation
More from Murrelektronik

Murrelektronik
ECO-RAIL-2 Power Supply 1-Phase, In: 90 ... 132 VAC / 173 … 264 VAC Out: 24V/5ADC
85133

Murrelektronik
M12 Steel male 0° A-cod. with cable TPE-S 4X0.34 gy 1.5M
7044-12021-3360150

Murrelektronik
RJ45 male 0° / RJ45 male 0° shielded FRNC/LS0H 4X2XAWG27 shielded bu UL 2M (7000-74711-8780200)
Murrelektronik
M12 male 0° / M12 male 0° D-cod. shielded PUR 1X4XAWG22 shielded gn UL/CSA+drag ch. 20M
7000-44511-7962000

Murrelektronik
Xenterra 8TX unmanaged Switch wallmounted 8 Port 100MBIT WM
58903

Murrelektronik
RJ45 male 0° / RJ45 male 0° shielded FRNC/LS0H 4X2XAWG27 shielded bu UL 1M (7000-74711-8780100)

Murrelektronik
M12 male 0° D-cod. / RJ45 male 0° shielded PUR 1X4XAWG22 shielded gn UL/CSA+drag ch. 25M
7000-44711-7962500

Murrelektronik
M12 Steel male 0° A-cod. with cable PVC 4X0.34 gy UL/CSA 10M
7044-12021-2141000
Catalogue entry last verified: 2026-09-30. A manufacturer datasheet is attached to this entry — confirm application-critical values against it.
Frequently asked questions
- Where can I buy 7000-40531-8030750?
- 7000-40531-8030750 can be ordered from cballast.com as a Murrelektronik catalogue item: request a quotation on this page or email sales@cballast.com, and the order ships worldwide.
- What is the manufacturer part number for this Murrelektronik product?
- The manufacturer part number is 7000-40531-8030750.
- What is the HS code for 7000-40531-8030750?
- The customs tariff (HS) code for 7000-40531-8030750 is 8544.42.
- Who manufactures 7000-40531-8030750?
- 7000-40531-8030750 is a Murrelektronik product in the Cables & Wiring range.
- Is a datasheet available for 7000-40531-8030750?
- Yes — the 7000-40531-8030750 datasheet can be viewed and downloaded on this page.
- What is the minimum order quantity for 7000-40531-8030750?
- The minimum order quantity is 1.
- Is 7000-40531-8030750 available?
- Yes — 7000-40531-8030750 is available to order: fulfilment is from supplier stock in cBallast's European network, dispatched directly from the warehouse to the customer, with the exact lead time stated in the quotation (reply within 24 hours).