Choose the highest resolution thermal camera in its price range. The Fluke Ti401 PRO thermal camera with 640x480 resolution is a valuable tool for your preventive maintenance program. Take advantage of advanced analytics software that offers asset tagging, streaming IR data and trend analysis.

Technical Specifications

Manufacturer part number (MPN)
5085041 Brand: Fluke Category: Tools Infrared resolution: 640 x 480 (307,200 pixels) SuperResolution: No IFOV with standard lens (spatial resolution): 0.93 mRad, D:S 1065:1 Field of view: 34 °H x 24 °V minimum focus distance: 15 cm (approx. 6 in) MultiSharp Focus: No LaserSharp Auto Focus: Yes, for consistently in-focus images. Every. Single. Time. Laser distance meter: Yes, calculates distance to the target for precisely focused images and displays distance on screen Advanced manual focus: Yes Wireless connectivity: Yes, to PC, iPhone® and iPad® (iOS 4s and later), Android™ 4.3 and up, and WiFi to LAN (where available) Fluke Connect app compatible: Yes*, connect your camera to your smartphone, and images taken automatically upload to the Fluke Connect app for saving and sharing Fluke Connect Assets: Through the desktop, assign images to assets, easily compare measurement types in one location and create reports. Fluke Connect instant cloud upload: Yes*, connect your camera to your building’s WiFi network, and images taken automatically upload to the Fluke Connect system for viewing on your smartphone or PC Fluke Connect instant server upload: Yes** IR-Fusion technology: Yes, adds the context of the visible details to your infrared image Ruggedized touchscreen display: 3.5 inch (landscape), 640 x 480 LCD Ergonomic design: Pistol-grip design for one-handed use Thermal sensitivity (NETD)**: ≤0.075 °C at 30 °C target temp (75 mK) Level and span: Smooth auto and manual scaling Touchscreen adjustable level/span: Yes. Span and level can be easily and quickly set by simply touching the screen Fast auto toggle between manual and auto modes: Yes Fast auto-rescale in manual mode: Yes minimum span (in manual mode): 2.0 °C (3.6 °F) minimum span (in auto mode): 3.0 °C (5.4 °F) Built-in digital camera (visible light): 5MP Frame rate: 60 Hz or 9 Hz versions Laser pointer: Yes LED light (torch): Yes digital zoom: No Extensive memory options: Removable 4 GB micro SD memory card, 4 GB internal flash memory, save to USB flash drive capability, upload for permanent storage Image capture, review, save mechanism: One-handed image capture, review, and save capability Image file formats: bmp, jpeg, is2 Memory review: Thumbnail and full screen review Software: Full analysis and reporting software with access to the Fluke Connect system Analyze and store radiometric data on a PC: Yes Export file formats with Fluke Connect software: Bitmap (.bmp), GIF, JPEG, PNG, TIFF Voice annotation: 60 seconds maximum recording time per image; reviewable playback on camera, optional Bluetooth headset available but not required IR-PhotoNotes: Yes - 2 images Text annotations: Yes. Including standard shortcuts as well as user programmable options Video recording and formats: No Remote control operations: Remote display through Fluke Connect Auto capture (temperature and interval): No Batteries (field-replaceable, rechargeable): Two lithium ion smart battery packs with five-segment LED display to show charge level Battery life: 2-3 hours per battery (actual life varies depending on settings and usage) Battery charging time: 2.5 hours to full charge Battery charging system: Two-bay battery charger or in-imager charging. Optional 12 V automotive charging adapter AC operation: AC operation with included power supply (100 V AC to 240 V AC, 50/60 Hz) Power saving: User selectable sleep and power off modes Temperature measurement range (not calibrated below -10 °C): -20 °C to +650 °C (-4 °F to +1,202 °F) Accuracy: ±2 °C or 2 % (at 25 °C nominal, whichever is greater) On-screen emissivity correction: Yes (both value and table) On-screen reflected background temperature compensation: Yes On-screen transmission correction: Yes Line temperature graph: No Standard palettes: 9: Rainbow, Ironbow, Blue-Red, High Contrast, Amber, Amber Inverted, Hot Metal, Grayscale, Grayscale Inverted Ultra Contrast palettes: 9: Rainbow, Ironbow, Blue-Red, High Contrast, Amber, Amber Inverted, Hot Metal, Grayscale, Grayscale Inverted Color alarms (temperature alarms): High temperature, low temperature, and isotherms (within range) Infrared spectral band: 7.5 μm to 14 μm (long wave) Operating temperature: -10 °C to +50 °C (+14 °F to +122 °F) Storage temperature: -20 °C to +50 °C (-4 °F to +122 °F) Relative humidity: 10 % to 95 % non-condensing Center-point temperature measurement: Yes Spot temperature: Hot and cold spot markers User-definable spot markers: No User defined measurement boxes: 1 expandable-contractible measurement box with MIN-MAX-AVG temp display Hard Case: Rugged, hard carrying case; soft transport bag Safety: IEC 61010-1: Overvoltage category II, Pollution Degree 2 Electromagnetic compatibility: IEC 61326-1: Basic EM environment. CISPR 11: Group 1, Class A Australian RCM: IEC 61326-1 US FCC: CFR 47, Part 15 Subpart B Vibration: 0.03 g2/Hz (3.8 g), 2.5 g IEC 60068-2-6 Shock: 25 g, IEC 68-2-29 Drop: Engineered to withstand 2 meter (6.5 feet) drop with standard lens Size (H x W x L): 27.7 x 12.2 x 16.7 cm (10.9 x 4.8 x 6.5 in) Weight (battery included): 1.04 kg (2.3 lb) Enclosure rating: IEC 60529: IP54 (protected against dust, limited ingress; protection against water spray from all directions) Warranty: Two-years (standard), extended warranties are available Recommended calibration cycle: Two-years (assumes normal operation and normal aging) Supported languages: Czech, Dutch, English, Finnish, French, German, Hungarian, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, and Turkish RoHS compliant: Yes

Cross References

  • OEM-URL https://www.fluke.com/en-us/product/thermal-cameras/ti401-pro

Catalogue entry last verified: 2026-08-30. A manufacturer datasheet is attached to this entry — confirm application-critical values against it.

Frequently asked questions

Where can I buy 5085041?
5085041 can be ordered from cballast.com as a Fluke catalogue item: request a quotation on this page or email sales@cballast.com, and the order ships worldwide.
What is the manufacturer part number for this Fluke product?
The manufacturer part number is 5085041.
Who manufactures 5085041?
5085041 is a Fluke product in the Safety & Detection range.
Is a datasheet available for 5085041?
Yes — the 5085041 datasheet can be viewed and downloaded on this page.
What is the minimum order quantity for 5085041?
The minimum order quantity is 1.
Is 5085041 available?
Yes — 5085041 is available to order: fulfilment is from supplier stock in cBallast's European network, dispatched directly from the warehouse to the customer, with the exact lead time stated in the quotation (reply within 24 hours).
How do I get a price for 5085041?
Request a quotation with the quote button on this page or by email to sales@cballast.com — we reply within 24 hours with price, availability and lead time.