Fluke 1551A/1552A Intrinsically Safe Thermometers
Fluke

Fluke 1551A/1552A Intrinsically Safe Thermometers

Part number3624136HS code9025.19
MOQ:1

Pricing

Request a quote

We reply within 24 hours

Product Description

Accurate, stable, and durable, the Fluke Calibration 1551A/1552A Connector thermometers are intrinsically safe for use in hazardous environments.

Technical Specifications

Manufacturer part number (MPN)
3624136 Brand: Fluke Category: Tools Temperature range: -50°C to 160°C (-58°F to 320°F) Accuracy (1 year): ±0.05°C (±0.09°F) Temperature resolution: Selectable: 0.1, 0.01, 0.001 (default 0.01) Sample rate: Selectable: 0.5 seconds, 1 second, 2 seconds (default 1 second) Readout temperature coefficient: Add ±10 ppm/°C of full scale temperature from −10 °C to 18 °C and 28 °C to 50 °C Probe temperature coefficient: 0.00385 Ω/Ω/°C nominal Nominal probe resistance at 0 °C: 100 Ω Probe hysteresis: ±0.01°C Response time: 4.8 mm diameter probe (3/16 in): 14 seconds 6.35 mm diameter probe (1/4 in): 21 seconds Operating temperature range readout: -10°C to 50°C (14°F to 122°F) Storage temperature: -20°C to 60°C (-4°F to 140°F) 0% to 95% RH, non-condensing Display units: °C, °F Sensor type: 100 Ω thin-film RTD Sensor length: ≤ 10 mm Sensor position (from sheath tip): 3 mm (0.1 in) minimum immersion depth: Wet medium (liquid bath, thermowell with thermal compound) 70 mm (2.8 in) Dry medium (dry-well, thermowell without thermal compound) 120 mm (4.8 in) Maximum immersion depth: 50 mm (2 in) less than the total length. Make sure the last 50 mm of probe, nearest to the internal electronics of the device, are not put into the heat source. Probe sheath material: Stainless steel Optional data logging1: Up to 10,000 time-stamped readings stored to internal memory Logging intervals1: 2 seconds, 5 seconds, 10 seconds, 30 seconds, or 60 seconds Damping: Moving average of the most recent 2 to 10 readings (ON/OFF, 2, 5, 10) Communications: RS-232 stereo jack (access calibration parameters only) DC power: 3-AAA alkaline batteries See Users Manual for approved batteries Battery life: Approximately 300 hours (12.5 days) of continuous operation with the backlight off. Battery save (auto-off) range: Selectable from 1 to 30 minutes or can be disabled Safety: IEC 60079-0, IEC 60079-11: Ex ib IIB T4 Gb; IEC 61010-1: Pollution Degree 2 Size (readout only): 125 mm x 62 mm x 35 mm (5 in x 2.5 in x 1.4 in) Probe Size: 1551A-9: 4.8 mm x 229 mm (3/16 in x 9 in) 1551A-12: 6.35 mm x 305 mm (1/4 in x 12 in) 1551A-20: 6.35 mm x 508 mm (1/4 in x 20 in) Weight: 196 g (6.9 oz) Calibration (included): accredited, NIST-traceable Characterization: CVD

Standards & Compliance

HS Code
9025.19

Cross References

  • OEM-URL https://www.fluke.com/en-us/product/calibration-tools/temperature-calibrators/fluke-calibration-1551a

Catalogue entry last verified: 2026-10-03. A manufacturer datasheet is attached to this entry — confirm application-critical values against it.

Frequently asked questions

Where can I buy 3624136?
3624136 can be ordered from cballast.com as a Fluke catalogue item: request a quotation on this page or email sales@cballast.com, and the order ships worldwide.
What is the manufacturer part number for this Fluke product?
The manufacturer part number is 3624136.
What is the HS code for 3624136?
The customs tariff (HS) code for 3624136 is 9025.19.
Who manufactures 3624136?
3624136 is a Fluke product in the Safety & Detection range.
Is a datasheet available for 3624136?
Yes — the 3624136 datasheet can be viewed and downloaded on this page.
What is the minimum order quantity for 3624136?
The minimum order quantity is 1.
Is 3624136 available?
Yes — 3624136 is available to order: fulfilment is from supplier stock in cBallast's European network, dispatched directly from the warehouse to the customer, with the exact lead time stated in the quotation (reply within 24 hours).