Overview

Eaton GW SWD Profinet (EU5C-SWD-PROFINET) is listed under Control & Automation / Fieldbus I/O. Sales unit: pcs; Eaton catalogue number: 170124; Depth: 127 mm; Height: 90 mm; Width: 35 mm; Weight: 0.16 kg.

Technical Specifications

Manufacturer part number (MPN)
EU5C-SWD-PROFINET
EAN / GTIN
4015081666218
Sales unit
pcs
Eaton catalogue number
170124
Depth
127 mm
Height
90 mm
Width
35 mm
Weight
0.16 kg
Certifications
CSA; UL Category Control No.: NRQA; UL File No.: E221530; UL; IEC/EN 61131-2; UL report applies to both US and Canada
Constant acceleration
1 g, 9 - 150 Hz, according to IEC/EN 61131-2, Vibrations
Constant amplitude
3,5 mm, 5 - 9 Hz, according to IEC/EN 61131-2, Vibrations
Drop and topple
50 mm Drop height, Drop to IEC/EN 60068-2-31
Height of fall (IEC/EN 60068-2-32) - max
1 m
Mounting position
As required
Shock resistance
15 g, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 11 ms, 9 Impacts
Air pressure
795 - 1080 hPa (operation)
Ambient operating temperature - max
55 °C
Ambient storage temperature - max
70 °C
Ambient operating temperature - min
-25 °C
Ambient storage temperature - min
-40 °C
Climatic proofing
In accordance with IEC 60068-2
Operating temperature - max
55 °C
Operating temperature - min
-25 °C
Relative humidity
5 - 95 % (non-condensing, IEC/EN 60068-2-30)
Connection type
SWD: Plug, 8-pole; Push in terminals, Supply voltage; 2 x RJ45 (2-channel switch), Field bus interface
Data transfer rate
542 Byte, Fieldbus interface, Output data, max.; 125 kBit/s, SmartWire-DT; 250 kBit/s, SmartWire-DT; 800 Byte, Fieldbus interface, Input data, max.; 100 MBit/s, Fieldbus interface
Interfaces
Module type: PROFINET IO Device; Status display fieldbus interface for APL, SF, BF, LINK, RX/TX with Multi colour LED
LED indicator
Status indication of SmartWire-DT master: Green and red LEDs; Status indication of Supply voltage: LED; Status indication of SmartWire-DT network: Configurable green or red LED
Number of modules
99 (SmartWire-DT)
Protocol
PROFINET IO; PROFINET
Station
IP, Station address, Fieldbus interface; SmartWire-DT master, SmartWire-DT network
Equipment heat dissipation, current-dependent Pvid
4.4 W
Static heat dissipation, non-current-dependent Pvs
1 W
Inrush current
44 A (for 2 ms)
Power loss
Normally 1 W
Rated control supply voltage
24 V DC (UPOW, -15 %/+20 %); 24 V DC (UAUX, -15 %/+20 %)
Rated operational current (Ie)
0.7 A
Rated operational voltage
14.5 V (± 3 % - SmartWire-DT); Typically UAUX -0.2 V (for 24 V DC slaves)
Short-circuit protection
Yes, Short-circuit rating, SmartWire-DT supply voltage; No, external fuse FAZ Z3, Supply voltage UAux
Supply current - max
0.7 mA
Supply voltage at DC - max
28.8 V
Supply voltage at DC - min
20.4 V
Air discharge
8 kV, according to IEC 61131-2, level 3, ESD
Burst impulse
2 kV, Supply cable, according to IEC/EN 61131-2, Level 3; 1 kV; 1 kV, SmartWire-DT cable, according to IEC/EN 61131-2, Level 3
Contact discharge
4 kV, according to IEC/EN 61131-2, Level 2, ESD
Electromagnetic fields
3 V/m at 1.4 - 2 GHz (according to IEC/EN 61131-2:2008); 1 V/m at 2.0 - 2.7 GHz (according to IEC/EN 61131-2:2008); 10 V/m at 80 - 1000 MHz (according to IEC/EN 61131-2:2008)
Radiated RFI
10 V (IEC/EN 61131-2:2008, Level 3)
Radio interference class
Class A (EN 55011)
Surge rating
0.5 kV, Supply cable, Surge (IEC/EN 61131-2:2008, Level 1), EMC
Voltage dips
≤ 10 ms, Bridging voltage dips
Features
Potential isolation (Fieldbus Interface); Overload proof
Functions
For connection to field bus PROFINET as PROFINET IO-Device
Operating mode
Address allocation via PROFINET
Degree of protection
IP20
Mounting method
Top-hat rail fixing (according to IEC/EN 60715, 35 mm); Rail mounting possible; Screw fixing using fixing brackets ZB4-101-GF1 (accessories); Wall mounting/direct mounting
Overvoltage category
II
Pollution degree
2
Product category
SmartWire-DT coordinators
Repetition rate
1 s
Residual ripple
≤ 5 % (input voltage)
Suitable for
Safety functions
Terminal capacity
0.2 - 1.5 mm², solid; 0.25 - 1.5 mm², flexible with ferrule; 24 - 16 AWG, solid or stranded
Voltage type
DC
Explosion safety category for dust
None
Explosion safety category for gas
None
Potential isolation
Supply voltage UAUX: no; Between UPow and 15 V SmartWire-DT supply voltage: no
Protection against polarity reversal
Yes; Yes, for supply voltage (Siemens MPI optional)
Number of HW-interfaces USB
1
Number of interfaces PROFINET
2
Certified for UL hazardous location division 1
No
Certified for UL hazardous location division 2
No
Certified for UL hazardous location group A (acetylene)
No
Certified for UL hazardous location group B (hydrogen)
No
Certified for UL hazardous location group C (ethylene)
No
Certified for UL hazardous location group D (propane)
No
Certified for UL hazardous location group E (metal dusts)
No
Certified for UL hazardous location class I
No
Certified for UL hazardous location class II
No
Certified for UL hazardous location class III
No
Supporting protocol for EtherCAT
No
Supply voltage DC
20.4–28.8 V
Supporting protocol for TCP/IP
No
Supporting protocol for PROFIBUS
No
Supporting protocol for CAN
No
Supporting protocol for INTERBUS
No
Supporting protocol for ASI
No
Supporting protocol for KNX
No
Supporting protocol for Modbus
No
Supporting protocol for Data-Highway
No
Supporting protocol for DeviceNet
No
Supporting protocol for SUCONET
No
Supporting protocol for LON
No
Supporting protocol for SERCOS
No
Supporting protocol for PROFINET IO
Yes
Supporting protocol for PROFINET CBA
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for other bus systems
No
Radio standard Bluetooth
No
Radio standard WLAN 802.11
No
Radio standard GPRS
No
Radio standard eGPRS
No
Radio standard GSM
No
Radio standard LTE
No
Mobile communications standard 3G (UMTS)
No
IO link master
No
System accessory
Yes
With potential separation
No
Fieldbus connection over separate bus coupler possible
No
Suitable for rail mounting
Yes
Wall mounting/direct mounting
Yes
Front built-in possible
No
Rack-assembly possible
No
Suitable for safety functions
Yes
SIL according to IEC 61508
None

Standards & Compliance

HS Code
8538.90

Cross References

  • EAN 4015081666218
  • SAP 1000689679
  • Code 8609276

Product Documentation

Document preview: GW SWD Profinet (EU5C-SWD-PROFINET) — Specification Data Sheet (OEM)

Catalogue entry last verified: 2026-09-29. A manufacturer datasheet is attached to this entry — confirm application-critical values against it.

Frequently asked questions

Where can I buy EU5C-SWD-PROFINET?
EU5C-SWD-PROFINET can be ordered from cballast.com as a Eaton catalogue item: request a quotation on this page or email sales@cballast.com, and the order ships worldwide.
What is the manufacturer part number for this Eaton product?
The manufacturer part number is EU5C-SWD-PROFINET.
What is the HS code for EU5C-SWD-PROFINET?
The customs tariff (HS) code for EU5C-SWD-PROFINET is 8538.90.
Who manufactures EU5C-SWD-PROFINET?
EU5C-SWD-PROFINET is a Eaton product in the Control & Automation range.
Is a datasheet available for EU5C-SWD-PROFINET?
Yes — the EU5C-SWD-PROFINET datasheet can be viewed and downloaded on this page.
What is the minimum order quantity for EU5C-SWD-PROFINET?
The minimum order quantity is 1.
Is EU5C-SWD-PROFINET available?
Yes — EU5C-SWD-PROFINET is available to order: fulfilment is from supplier stock in cBallast's European network, dispatched directly from the warehouse to the customer, with the exact lead time stated in the quotation (reply within 24 hours).