Eaton
PKE Kont.module SWD DILM7-32
Part numberPKE-SWD-32EAN / GTIN4015081244751HS code8538.90
Control & Automation
I/O Modules
MOQ:1
Pricing
Request a quote
We reply within 24 hours
Overview
Eaton PKE Kont.module SWD DILM7-32 (part number PKE-SWD-32) is listed under Control & Automation / I/O Modules. Sales unit: pcs; Package quantity: 4 pcs; Eaton catalogue number: 126895; Depth: 81 mm; Height: 39 mm; Width: 54 mm.
Technical Specifications
- Manufacturer part number (MPN)
- PKE-SWD-32
- EAN / GTIN
- 4015081244751
- Sales unit
- pcs
- Package quantity
- 4 pcs
- Eaton catalogue number
- 126895
- Depth
- 81 mm
- Height
- 39 mm
- Width
- 54 mm
- Weight
- 0.043 kg
- Certifications
- CSA-C22.2 No. 14; IEC/EN 61131-2; IEC/EN 60947; CE; CSA; CSA Class No.: 3211-07; CSA File No.: 165628; UL508; UL; EN 50178; IEC60847-4-1; UL Category Control No.: NKCR; UL File No.: E29184
- Constant acceleration
- 1 g, 8.4 - 150 Hz, according to IEC/EN 61131-2, Vibrations
- Constant amplitude
- 3,5 mm, 5 - 8.4 Hz, according to IEC/EN 61131-2, Vibrations
- Drop and topple
- 50 mm Drop height, Drop to IEC/EN 60068-2-31
- Height of fall (IEC/EN 60068-2-32) - max
- 0.3 m
- Mounting position
- As DILM7 to DILM32
- Shock resistance
- 15 g, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 11 ms, 9 Impacts
- Ambient operating temperature - max
- 60 °C
- Ambient storage temperature - max
- 70 °C
- Ambient operating temperature - min
- -25 °C
- Ambient storage temperature - min
- -30 °C
- Environmental conditions
- Condensation: prevent with appropriate measures
- Relative humidity
- 5 - 95 % (non-condensing, IEC/EN 60068-2-30)
- Addressing
- Address set automatically
- Connection
- A2 connections must not be bridged.
- Connection to SmartWire-DT
- Yes
- Connection type
- External device plug SWD4-8SF2-5, SmartWire-DT; Push in terminals
- Auxiliary contact; SWD
- Plug, 8-pole
- LED indicator
- Status indication of SmartWire-DT network: Green and orange LED
- Station
- SmartWire-DT slave, SmartWire-DT network
- Static heat dissipation, non-current-dependent Pvs
- 0.9 W
- Output current
- 0.5 A
- Supply voltage at DC - max
- 15 VDC
- Supply voltage at DC - min
- 15 VDC
- Air discharge
- 8 kV, according to IEC 61131-2, level 3, ESD
- Burst impulse
- 1 kV, CAN/DP-bus cable, SmartWire-DT cables, according to IEC/EN 61131-2, Level 3; 1 kV, SmartWire-DT cable, Signal cable, according to IEC/EN 61131-2, Level 3
- Contact discharge
- 4 kV, according to IEC/EN 61131-2, Level 2, ESD
- Electromagnetic fields
- 10 V/m at 80 - 1000 MHz (according to IEC/EN 61131-2:2008); 3 V/m at 1.4 - 2 GHz (according to IEC/EN 61131-2:2008); 1 V/m at 2.0 - 2.7 GHz (according to IEC/EN 61131-2:2008)
- Radiated RFI
- 10 V (IEC/EN 61131-2:2008, Level 3)
- Radio interference class
- Class A (EN 55011)
- Electric connection type
- Spring clamp connection
- Features
- Fieldbus connection over separate bus coupler possible; Fieldbus connection over separate bus coupler possible
- Operating mode
- Manual operation possible; Address allocation via Rotary switch; Automatic operation possible
- Accessories
- Connecting cable between module and trip block PKE-XTUA-… included with supplied equipment.
- Cable length
- ≤ 2.8 m, Connection auxiliary contact
- Current consumption
- 58 mA, SmartWire-DT network, 15-V-SWD supply; See the contactor's pick-up current and holding current (max. 0.5 A), 24-V-DC-SWD control voltage Uaux
- Degree of protection
- IP20
- Explosion safety category for dust
- None
- Explosion safety category for gas
- None
- Number of inputs (digital)
- 0
- Number of outputs (digital)
- 1
- Overvoltage category
- II
- Pollution degree
- 2
- Product category
- Accessories SmartWire-DT slave
- Protocol
- Other bus systems
- Type
- SmartWire-DT PKE module (motor-starter combinations)
- Voltage type
- DC
- Terminal capacity
- 0.2 - 1.5 mm² (AWG 24 - 16), solid; 0.25 - 1.5 mm², flexible with ferrule
- Certified for UL hazardous location division 1
- No
- Certified for UL hazardous location division 2
- No
- Certified for UL hazardous location group A (acetylene)
- No
- Certified for UL hazardous location group B (hydrogen)
- No
- Certified for UL hazardous location group C (ethylene)
- No
- Certified for UL hazardous location group D (propane)
- No
- Certified for UL hazardous location group E (metal dusts)
- No
- Certified for UL hazardous location class I
- No
- Certified for UL hazardous location class II
- No
- Certified for UL hazardous location class III
- No
- Supporting protocol for EtherCAT
- No
- Supply voltage DC
- 15 V
- Number of digital outputs
- 1
- Digital inputs configurable
- No
- Digital outputs configurable
- No
- Permitted voltage at input
- 15 V
- Type of voltage (input voltage)
- DC
- Permitted voltage at output
- 20.4–28.8 V
- Type of output voltage
- DC
- Short-circuit protection, outputs available
- No
- Number of HW-interfaces other
- 2
- With optical interface
- No
- Supporting protocol for TCP/IP
- No
- Supporting protocol for PROFIBUS
- No
- Supporting protocol for CAN
- No
- Supporting protocol for INTERBUS
- No
- Supporting protocol for ASI
- No
- Supporting protocol for KNX
- No
- Supporting protocol for Modbus
- No
- Supporting protocol for Data-Highway
- No
- Supporting protocol for DeviceNet
- No
- Supporting protocol for SUCONET
- No
- Supporting protocol for LON
- No
- Supporting protocol for PROFINET IO
- No
- Supporting protocol for PROFINET CBA
- No
- Supporting protocol for SERCOS
- No
- Supporting protocol for Foundation Fieldbus
- No
- Supporting protocol for EtherNet/IP
- No
- Supporting protocol for AS-Interface Safety at Work
- No
- Supporting protocol for DeviceNet Safety
- No
- Supporting protocol for INTERBUS-Safety
- No
- Supporting protocol for PROFIsafe
- No
- Supporting protocol for SafetyBUS p
- No
- Supporting protocol for other bus systems
- Yes
- Radio standard Bluetooth
- No
- Radio standard WLAN 802.11
- No
- Radio standard GPRS
- No
- Radio standard GSM
- No
- Mobile communications standard 3G (UMTS)
- No
- IO link master
- No
- System accessory
- Yes
- Type of electric connection
- Spring clamp connection
- Time delay at signal change
- 10–84 ms
- Fieldbus connection over separate bus coupler possible
- Yes
- Suitable for rail mounting
- No
- Wall mounting/direct mounting
- No
- Front built-in possible
- No
- Rack-assembly possible
- No
- Suitable for safety functions
- No
- SIL according to IEC 61508
- None
- Performance level according to EN ISO 13849-1
- None
- Appendant operation agent (Ex ia)
- No
- Country of origin
- Germany
Standards & Compliance
- HS Code
- 8538.90
Cross References
- EAN 4015081244751
- SAP 1000289029
- Code 81038427
Product Documentation
Document preview: PKE Kont.module SWD DILM7-32 (PKE-SWD-32) — Specification Data Sheet (OEM)
More from Eaton

Eaton
Cylindrical Fuse 14X51MM, 2A
C14G2

Eaton
Led Flashing light, Red, 24V (SL4-BL24-R)

Eaton
Connection Terminal 16-120mm², f 5mm
AKU120/5

Eaton
Serviceswitch 3P 160A
DMM-160/3/I5/P-G

Eaton
Lacquer, RAL9016 (PAINT-RAL9016)

Eaton
Eaton FRCMM-63/4/03-G/A (170305)

Eaton
Eaton 5P 650I Rack 1U Netpack G2
5P650IRNG2

Eaton
Auxiliary contact (NHI12-PKZ0)
Catalogue entry last verified: 2026-09-29. A manufacturer datasheet is attached to this entry — confirm application-critical values against it.
Frequently asked questions
- Where can I buy PKE-SWD-32?
- PKE-SWD-32 can be ordered from cballast.com as a Eaton catalogue item: request a quotation on this page or email sales@cballast.com, and the order ships worldwide.
- What is the manufacturer part number for this Eaton product?
- The manufacturer part number is PKE-SWD-32.
- What is the HS code for PKE-SWD-32?
- The customs tariff (HS) code for PKE-SWD-32 is 8538.90.
- Who manufactures PKE-SWD-32?
- PKE-SWD-32 is a Eaton product in the Control & Automation range.
- Is a datasheet available for PKE-SWD-32?
- Yes — the PKE-SWD-32 datasheet can be viewed and downloaded on this page.
- What is the minimum order quantity for PKE-SWD-32?
- The minimum order quantity is 1.
- Is PKE-SWD-32 available?
- Yes — PKE-SWD-32 is available to order: fulfilment is from supplier stock in cBallast's European network, dispatched directly from the warehouse to the customer, with the exact lead time stated in the quotation (reply within 24 hours).