Eaton Can Open Gateway (XNE-GWBR-CANOPEN) is listed under Control & Automation / Fieldbus I/O. Sales unit: pcs; Eaton catalogue number: 140044; Depth: 129 mm; Height: 75 mm; Width: 33.5 mm; Weight: 0.136 kg.
Technical Specifications
- Manufacturer part number (MPN)
- XNE-GWBR-CANOPEN
- EAN / GTIN
- 7640130120600
- Sales unit
- pcs
- Eaton catalogue number
- 140044
- Depth
- 129 mm
- Height
- 75 mm
- Width
- 33.5 mm
- Weight
- 0.136 kg
- Certifications
- cULus; IEC/EN 61000-6-2; IEC/EN 61131-2; Rated data for terminations according to IEC/EN 60947-7-1; CE; IEC/EN 6113-2; IEC/EN 61000-6-4
- Catalog Notes
- supports up to 62 disc-type modules (XN, XNE)
- Drop and topple
- According to IEC 60068-2-31, free fall according to IEC 60068-2-32
- Shock resistance
- Mechanical, According to IEC/EN 60068-2-27; Continuous according to IEC/EN 60068-2-29
- Vibration resistance
- According to IEC/EN 60068-2-6
- Ambient operating temperature - max
- 55 °C
- Ambient storage temperature - max
- 85 °C
- Ambient operating temperature - min
- 0 °C
- Ambient storage temperature - min
- -25 °C
- Environmental conditions
- Harmful gasses - H2S: 1 ppm (relative humidity < 75%, no condensation); Harmful gasses - SO2: 10 ppm (relative humidity < 75%, no condensation)
- Relative humidity
- 5 - 95 % (indoor, Level RH-2, non-condensing for storage at 45°C)
- Addressing
- Address set via DIP switch; Address range: 1 - 63 decimal
- Bus termination
- Via DIP switch, Networking
- Connection type
- Push-In spring-cage terminals, Field bus; Spring-cage terminals, Field bus/Supply voltage); Push-In spring-cage terminals, Connection design in TOP direction
- Data transfer rate
- 800 kBit/s; 50 kBit/s; 500 kBit/s, Networking; 800 kBit/s, Networking; 125 kBit/s, Networking; 250 kBit/s; 10 kBit/s, Networking; 1000 kBit/s, Networking; 1000 kBit/s; 20 kBit/s; Setting through DIP switch or automatically; 50 kBit/s, Networking; 250 kBit/s, Networking; 500 kBit/s; 125 kBit/s
- Field voltage
- 24 V DC (UL)
- Interfaces
- PS/2 socket (Service interface); CANopen®, Field bus connection
- Protocol
- CANopen®; CAN; Other bus systems
- Static heat dissipation, non-current-dependent Pvs
- 6 W
- Supply voltage
- 4.7 - 5.3 V DC
- Supply voltage at AC
- Supply voltage at AC
- Supply voltage at DC - max
- 30 V
- Supply voltage at DC - min
- 18 V
- Air discharge
- According to EN 61100-4-2
- Burst impulse
- According to IEC/EN 61000-4-4
- Contact discharge
- According to EN 61100-4-2
- Electromagnetic fields
- According to IEC EN 61100-4-2
- Emitted interference
- 230 - 1000 MHz (radiated, high frequency, according to EN 55016-2-3); 30 - 230 MHz (radiated, high frequency, according to EN 55016-2-3)
- Radiated RFI
- IEC/EN 61100-4-6
- Surge rating
- According to IEC/EN 61000-4-5 Level 4
- Voltage dips
- According to EN 61131-2 (Voltage fluctuations/voltage dips)
- Features
- Fieldbus connection over separate bus coupler possible
- Fitted with
- Bus refreshing module; Potential separation
- Accessories
- 1 x end plate XN-ABPL and 2 x end bracket XN-WEW-32/2-SW included with supplied equipment.
- Admissible range
- 18 - 30 V DC, Networking
- Configuration
- Maximum station configuration: 62 cards (XN
- XNE) of slice design or max. length of station
- 1 m
- Degree of protection
- IP20
- Mounting method
- Rail mounting possible
- Residual ripple
- According to EN 61131-2
- Type
- XI/ON ECO gateways XNE-Gateway with integrated supply
- Voltage type
- DC
- Explosion safety category for dust
- None
- Explosion safety category for gas
- None
- Potential isolation
- Through optocoupler: yes
- Gauge pin
- A1 (according to IEC/EN 60947-1)
- Stripping length (main cable)
- 8 mm
- Terminal capacity
- 0.25 - 1.5 mm², with ferrules without plastic collar; 0.25 - 1.5 mm², solid; 0.25 - 1.5 mm², flexible without ferrule; 0.25 - 0.75 mm², with ferrules with plastic collar
- Certified for UL hazardous location division 1
- No
- Certified for UL hazardous location division 2
- No
- Certified for UL hazardous location group A (acetylene)
- No
- Certified for UL hazardous location group B (hydrogen)
- No
- Certified for UL hazardous location group C (ethylene)
- No
- Certified for UL hazardous location group D (propane)
- No
- Certified for UL hazardous location group E (metal dusts)
- No
- Certified for UL hazardous location class I
- No
- Certified for UL hazardous location class II
- No
- Certified for UL hazardous location class III
- No
- Supporting protocol for EtherCAT
- No
- Supply voltage DC
- 18–30 V
- Supporting protocol for TCP/IP
- No
- Supporting protocol for PROFIBUS
- No
- Supporting protocol for CAN
- Yes
- Supporting protocol for INTERBUS
- No
- Supporting protocol for ASI
- No
- Supporting protocol for KNX
- No
- Supporting protocol for Modbus
- No
- Supporting protocol for Data-Highway
- No
- Supporting protocol for DeviceNet
- No
- Supporting protocol for SUCONET
- No
- Supporting protocol for LON
- No
- Supporting protocol for SERCOS
- No
- Supporting protocol for PROFINET IO
- No
- Supporting protocol for PROFINET CBA
- No
- Supporting protocol for Foundation Fieldbus
- No
- Supporting protocol for EtherNet/IP
- No
- Supporting protocol for AS-Interface Safety at Work
- No
- Supporting protocol for DeviceNet Safety
- No
- Supporting protocol for INTERBUS-Safety
- No
- Supporting protocol for PROFIsafe
- No
- Supporting protocol for SafetyBUS p
- No
- Supporting protocol for other bus systems
- No
- Radio standard Bluetooth
- No
- Radio standard WLAN 802.11
- No
- Radio standard GPRS
- No
- Radio standard eGPRS
- No
- Radio standard GSM
- No
- Radio standard LTE
- No
- Mobile communications standard 3G (UMTS)
- No
- IO link master
- No
- System accessory
- Yes
- With potential separation
- No
- Fieldbus connection over separate bus coupler possible
- Yes
- Suitable for rail mounting
- Yes
- Wall mounting/direct mounting
- No
- Front built-in possible
- No
- Rack-assembly possible
- No
- Suitable for safety functions
- No
- SIL according to IEC 61508
- None
- Performance level according to EN ISO 13849-1
- None
- Appendant operation agent (Ex ia)
- No
- Country of origin
- Germany
Standards & Compliance
- HS Code
- 8538.90
Cross References
- EAN 7640130120600
- SAP 1000288965
- Code 895428
Product Documentation
More from Eaton

Eaton
Eaton NZMH1-M80

Eaton
Transformer protection switch,PKZM0-4-T-PI

Eaton
NH1E Cover Replacement XNH2015
XNH1-XGRIP-FCE

Eaton
Panel board m/DIN B=600mm H=1260mm H
BP-O-600/12-C-W

Eaton
Direct-on-line starter,MSC-D-10-M9(230V50HZ)-PI

Eaton
DIN rail set meter enclosure (BPZ-DRS-MT-MSW-1200/400-3-A)

Eaton
Backplate Sealed IP55 H=2000 B=13
XSWC20135

Eaton
Eaton CWIZ-01/27 Single Rocker 55x55 mm Matt Alpine White Up/Down
Catalogue entry last verified: 2026-09-29. A manufacturer datasheet is attached to this entry — confirm application-critical values against it.
Frequently asked questions
- Where can I buy XNE-GWBR-CANOPEN?
- XNE-GWBR-CANOPEN can be ordered from cballast.com as a Eaton catalogue item: request a quotation on this page or email sales@cballast.com, and the order ships worldwide.
- What is the manufacturer part number for this Eaton product?
- The manufacturer part number is XNE-GWBR-CANOPEN.
- What is the HS code for XNE-GWBR-CANOPEN?
- The customs tariff (HS) code for XNE-GWBR-CANOPEN is 8538.90.
- Who manufactures XNE-GWBR-CANOPEN?
- XNE-GWBR-CANOPEN is a Eaton product in the Control & Automation range.
- Is a datasheet available for XNE-GWBR-CANOPEN?
- Yes — the XNE-GWBR-CANOPEN datasheet can be viewed and downloaded on this page.
- What is the minimum order quantity for XNE-GWBR-CANOPEN?
- The minimum order quantity is 1.
- Is XNE-GWBR-CANOPEN available?
- Yes — XNE-GWBR-CANOPEN is available to order: fulfilment is from supplier stock in cBallast's European network, dispatched directly from the warehouse to the customer, with the exact lead time stated in the quotation (reply within 24 hours).