Eff.m.Darw SWD's,kont/start (EU5C-SWD-PF2-1)
Eaton

Eff.m.Darw SWD's,kont/start (EU5C-SWD-PF2-1)

Part numberEU5C-SWD-PF2-1EAN / GTIN4015081161102HS code8538.90
MOQ:1

Pricing

Request a quote

We reply within 24 hours

Overview

Eaton Eff.m.Darw SWD's,kont/start (EU5C-SWD-PF2-1) is listed in the cBallast industrial catalogue. Sales unit: pcs; Eaton catalogue number: 116380; Depth: 125 mm; Height: 90 mm; Width: 35 mm; Weight: 0.16 kg.

Technical Specifications

Manufacturer part number (MPN)
EU5C-SWD-PF2-1
EAN / GTIN
4015081161102
Sales unit
pcs
Eaton catalogue number
116380
Depth
125 mm
Height
90 mm
Width
35 mm
Weight
0.16 kg
Certifications
UL Category Control No.: NKCR; CSA; CSA Class No.: 3211-07; IEC/EN 61131-2; UL File No.: E29184; EN 50178; UL; CSA File No.: 2324643
Catalog Notes
SmartWire-DT power supply for SmartWire-DT modules and for additionally feeding the control voltage for motor starters and contactors, as well as for establishing emergency stop groups
Constant acceleration
1 g, 8.4 - 150 Hz, according to IEC/EN 61131-2, Vibrations
Constant amplitude
3,5 mm, 5 - 8.4 Hz, according to IEC/EN 61131-2, Vibrations
Drop and topple
50 mm Drop height, Drop to IEC/EN 60068-2-31
Height of fall (IEC/EN 60068-2-32) - max
0.3 m
Mounting position
As required
Shock resistance
15 g, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 11 ms, 9 Impacts
Air pressure
795 - 1080 hPa (operation)
Ambient operating temperature - max
55 °C
Ambient storage temperature - max
70 °C
Ambient operating temperature - min
-25 °C
Ambient storage temperature - min
-40 °C
Climatic proofing
Damp heat, constant, to IEC 60068-2-3; Dry heat to IEC 60068-2-2
Environmental conditions
Condensation: prevent with appropriate measures
Operating temperature - max
55 °C
Operating temperature - min
-25 °C
Relative humidity
5 - 95 % (non-condensing, IEC/EN 60068-2-30)
Connection
2 x SmartWire-DT blade terminal SWD4-8MF2
Connection to SmartWire-DT
Yes
Connection type
SWD: 2 x plug, 8-pole; Push in terminals, Supply voltage
LED indicator
Status indication of Supply voltage: LED
Protocol
Other bus systems
Static heat dissipation, non-current-dependent Pvs
2.7 W
Inrush current
12.5 A (for 6 ms)
Power loss
Normally 2.7 W
Rated control supply voltage
24 V DC (UPOW, -15 %/+20 %); 24 V DC (UAUX, -15 %/+20 %)
Rated operational current (Ie) - max
0.7 A
Rated operational voltage
Typically UAUX -0.2 V (for 24 V DC slaves); 14.5 V (± 3 % - SmartWire-DT)
Short-circuit protection
Yes, Short-circuit rating, SmartWire-DT supply voltage; No, external fuse FAZ Z3, Supply voltage UAux
Supply current
0.7 A, Imax, SmartWire-DT supply; 3 A, Imax, Supply voltage UAux
Supply voltage at DC - max
28.8 VDC
Supply voltage at DC - min
20.4 VDC
Air discharge
8 kV, according to IEC 61131-2, level 3, ESD
Burst impulse
2 kV, Supply cable, according to IEC/EN 61131-2, Level 3; 1 kV, SmartWire-DT cable, according to IEC/EN 61131-2, Level 3
Contact discharge
4 kV, according to IEC/EN 61131-2, Level 2, ESD
Electromagnetic fields
3 V/m at 1.4 - 2 GHz (according to IEC/EN 61131-2:2008); 1 V/m at 2.0 - 2.7 GHz (according to IEC/EN 61131-2:2008); 10 V/m at 80 - 1000 MHz (according to IEC/EN 61131-2:2008)
Radiated RFI
10 V (IEC/EN 61131-2:2008, Level 3)
Radio interference class
Class A (EN 55011)
Surge rating
0.5 kV, Supply cables/CAN/DP bus cable, Surge power cables, Surge (IEC/EN 61131-2:2008, Level 1), EMC
Voltage dips
≤ 10 ms, Bridging voltage dips
Electric connection type
Flat plug-in connection
Features
Fieldbus connection over separate bus coupler possible; Overload proof; Fieldbus connection over separate bus coupler possible
Fitted with
Power supply module; Potential separation
Functions
For additional control voltage feeder for the motor starter and contactors; For the formation of emergency switching off groups for motor starters and contactors; For feeding supply voltage in order to connect additional SmartWire-DT modules to the SmartWire-DT ribbon cable
Degree of protection
IP20
Mounting method
Rail mounting possible; Wall mounting/direct mounting; Top-hat rail fixing (according to IEC/EN 60715, 35 mm)
Overvoltage category
II
Pollution degree
2
Product category
SmartWire-DT accessories
Repetition rate
1 s
Residual ripple
≤ 5 % (input voltage)
Suitable as
Segment module
Terminal capacity
0.25 - 1.5 mm², flexible with ferrule; 24 - 16 AWG, solid or stranded; 0.2 - 1.5 mm², solid
Voltage type
DC
Explosion safety category for dust
None
Explosion safety category for gas
None
Potential isolation
Between UPow and 15 V SmartWire-DT supply voltage: yes
Protection against polarity reversal
Yes; Yes, for supply voltage (Siemens MPI optional)
Certified for UL hazardous location division 1
No
Certified for UL hazardous location division 2
No
Certified for UL hazardous location group A (acetylene)
No
Certified for UL hazardous location group B (hydrogen)
No
Certified for UL hazardous location group C (ethylene)
No
Certified for UL hazardous location group D (propane)
No
Certified for UL hazardous location group E (metal dusts)
No
Certified for UL hazardous location class I
No
Certified for UL hazardous location class II
No
Certified for UL hazardous location class III
No
Supporting protocol for EtherCAT
No
Supply voltage DC
20.4–28.8 V
Number of HW-interfaces other
1
With optical interface
No
Supporting protocol for TCP/IP
No
Supporting protocol for PROFIBUS
No
Supporting protocol for CAN
No
Supporting protocol for INTERBUS
No
Supporting protocol for ASI
No
Supporting protocol for KNX
No
Supporting protocol for Modbus
No
Supporting protocol for Data-Highway
No
Supporting protocol for DeviceNet
No
Supporting protocol for SUCONET
No
Supporting protocol for LON
No
Supporting protocol for PROFINET IO
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for SERCOS
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for other bus systems
Yes
Radio standard Bluetooth
No
Radio standard WLAN 802.11
No
Radio standard GPRS
No
Radio standard GSM
No
Mobile communications standard 3G (UMTS)
No
System accessory
Yes
Type of electric connection
Flat plug-in connection
With potential separation
Yes
With power supply module
Yes
Suitable as segment module
Yes
Remote module
No
Fieldbus connection over separate bus coupler possible
Yes
Bus diagnosis possible
No
Suitable for rail mounting
Yes
Wall mounting/direct mounting
Yes
Front built-in possible
No
Rack-assembly possible
No

Standards & Compliance

HS Code
8538.90

Cross References

  • EAN 4015081161102
  • SAP 1000288892
  • Code 8297394

Product Documentation

Document preview: Eff.m.Darw SWD's,kont/start (EU5C-SWD-PF2-1) — Specification Data Sheet (OEM)

Catalogue entry last verified: 2026-08-29. A manufacturer datasheet is attached to this entry — confirm application-critical values against it.

Frequently asked questions

Where can I buy EU5C-SWD-PF2-1?
EU5C-SWD-PF2-1 can be ordered from cballast.com as a Eaton catalogue item: request a quotation on this page or email sales@cballast.com, and the order ships worldwide.
What is the manufacturer part number for this Eaton product?
The manufacturer part number is EU5C-SWD-PF2-1.
What is the HS code for EU5C-SWD-PF2-1?
The customs tariff (HS) code for EU5C-SWD-PF2-1 is 8538.90.
Who manufactures EU5C-SWD-PF2-1?
EU5C-SWD-PF2-1 is a Eaton product in the SC001600 range.
Is a datasheet available for EU5C-SWD-PF2-1?
Yes — the EU5C-SWD-PF2-1 datasheet can be viewed and downloaded on this page.
What is the minimum order quantity for EU5C-SWD-PF2-1?
The minimum order quantity is 1.
Is EU5C-SWD-PF2-1 available?
Yes — EU5C-SWD-PF2-1 is available to order: fulfilment is from supplier stock in cBallast's European network, dispatched directly from the warehouse to the customer, with the exact lead time stated in the quotation (reply within 24 hours).