| Manufacturer part number (MPN) | EU5C-SWD-PF2-1 |
| EAN / GTIN | 4015081161102 |
| Sales unit | pcs |
| Eaton catalogue number | 116380 |
| Depth | 125 mm |
| Height | 90 mm |
| Width | 35 mm |
| Weight | 0.16 kg |
| Certifications | UL Category Control No.: NKCR; CSA; CSA Class No.: 3211-07; IEC/EN 61131-2; UL File No.: E29184; EN 50178; UL; CSA File No.: 2324643 |
| Catalog Notes | SmartWire-DT power supply for SmartWire-DT modules and for additionally feeding the control voltage for motor starters and contactors, as well as for establishing emergency stop groups |
| Constant acceleration | 1 g, 8.4 - 150 Hz, according to IEC/EN 61131-2, Vibrations |
| Constant amplitude | 3,5 mm, 5 - 8.4 Hz, according to IEC/EN 61131-2, Vibrations |
| Drop and topple | 50 mm Drop height, Drop to IEC/EN 60068-2-31 |
| Height of fall (IEC/EN 60068-2-32) - max | 0.3 m |
| Mounting position | As required |
| Shock resistance | 15 g, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 11 ms, 9 Impacts |
| Air pressure | 795 - 1080 hPa (operation) |
| Ambient operating temperature - max | 55 °C |
| Ambient storage temperature - max | 70 °C |
| Ambient operating temperature - min | -25 °C |
| Ambient storage temperature - min | -40 °C |
| Climatic proofing | Damp heat, constant, to IEC 60068-2-3; Dry heat to IEC 60068-2-2 |
| Environmental conditions | Condensation: prevent with appropriate measures |
| Operating temperature - max | 55 °C |
| Operating temperature - min | -25 °C |
| Relative humidity | 5 - 95 % (non-condensing, IEC/EN 60068-2-30) |
| Connection | 2 x SmartWire-DT blade terminal SWD4-8MF2 |
| Connection to SmartWire-DT | Yes |
| Connection type | SWD: 2 x plug, 8-pole; Push in terminals, Supply voltage |
| LED indicator | Status indication of Supply voltage: LED |
| Protocol | Other bus systems |
| Static heat dissipation, non-current-dependent Pvs | 2.7 W |
| Inrush current | 12.5 A (for 6 ms) |
| Power loss | Normally 2.7 W |
| Rated control supply voltage | 24 V DC (UPOW, -15 %/+20 %); 24 V DC (UAUX, -15 %/+20 %) |
| Rated operational current (Ie) - max | 0.7 A |
| Rated operational voltage | Typically UAUX -0.2 V (for 24 V DC slaves); 14.5 V (± 3 % - SmartWire-DT) |
| Short-circuit protection | Yes, Short-circuit rating, SmartWire-DT supply voltage; No, external fuse FAZ Z3, Supply voltage UAux |
| Supply current | 0.7 A, Imax, SmartWire-DT supply; 3 A, Imax, Supply voltage UAux |
| Supply voltage at DC - max | 28.8 VDC |
| Supply voltage at DC - min | 20.4 VDC |
| Air discharge | 8 kV, according to IEC 61131-2, level 3, ESD |
| Burst impulse | 2 kV, Supply cable, according to IEC/EN 61131-2, Level 3; 1 kV, SmartWire-DT cable, according to IEC/EN 61131-2, Level 3 |
| Contact discharge | 4 kV, according to IEC/EN 61131-2, Level 2, ESD |
| Electromagnetic fields | 3 V/m at 1.4 - 2 GHz (according to IEC/EN 61131-2:2008); 1 V/m at 2.0 - 2.7 GHz (according to IEC/EN 61131-2:2008); 10 V/m at 80 - 1000 MHz (according to IEC/EN 61131-2:2008) |
| Radiated RFI | 10 V (IEC/EN 61131-2:2008, Level 3) |
| Radio interference class | Class A (EN 55011) |
| Surge rating | 0.5 kV, Supply cables/CAN/DP bus cable, Surge power cables, Surge (IEC/EN 61131-2:2008, Level 1), EMC |
| Voltage dips | ≤ 10 ms, Bridging voltage dips |
| Electric connection type | Flat plug-in connection |
| Features | Fieldbus connection over separate bus coupler possible; Overload proof; Fieldbus connection over separate bus coupler possible |
| Fitted with | Power supply module; Potential separation |
| Functions | For additional control voltage feeder for the motor starter and contactors; For the formation of emergency switching off groups for motor starters and contactors; For feeding supply voltage in order to connect additional SmartWire-DT modules to the SmartWire-DT ribbon cable |
| Degree of protection | IP20 |
| Mounting method | Rail mounting possible; Wall mounting/direct mounting; Top-hat rail fixing (according to IEC/EN 60715, 35 mm) |
| Overvoltage category | II |
| Pollution degree | 2 |
| Product category | SmartWire-DT accessories |
| Repetition rate | 1 s |
| Residual ripple | ≤ 5 % (input voltage) |
| Suitable as | Segment module |
| Terminal capacity | 0.25 - 1.5 mm², flexible with ferrule; 24 - 16 AWG, solid or stranded; 0.2 - 1.5 mm², solid |
| Voltage type | DC |
| Explosion safety category for dust | None |
| Explosion safety category for gas | None |
| Potential isolation | Between UPow and 15 V SmartWire-DT supply voltage: yes |
| Protection against polarity reversal | Yes; Yes, for supply voltage (Siemens MPI optional) |
| Certified for UL hazardous location division 1 | No |
| Certified for UL hazardous location division 2 | No |
| Certified for UL hazardous location group A (acetylene) | No |
| Certified for UL hazardous location group B (hydrogen) | No |
| Certified for UL hazardous location group C (ethylene) | No |
| Certified for UL hazardous location group D (propane) | No |
| Certified for UL hazardous location group E (metal dusts) | No |
| Certified for UL hazardous location class I | No |
| Certified for UL hazardous location class II | No |
| Certified for UL hazardous location class III | No |
| Supporting protocol for EtherCAT | No |
| Supply voltage DC | 20.4–28.8 V |
| Number of HW-interfaces other | 1 |
| With optical interface | No |
| Supporting protocol for TCP/IP | No |
| Supporting protocol for PROFIBUS | No |
| Supporting protocol for CAN | No |
| Supporting protocol for INTERBUS | No |
| Supporting protocol for ASI | No |
| Supporting protocol for KNX | No |
| Supporting protocol for Modbus | No |
| Supporting protocol for Data-Highway | No |
| Supporting protocol for DeviceNet | No |
| Supporting protocol for SUCONET | No |
| Supporting protocol for LON | No |
| Supporting protocol for PROFINET IO | No |
| Supporting protocol for PROFINET CBA | No |
| Supporting protocol for SERCOS | No |
| Supporting protocol for Foundation Fieldbus | No |
| Supporting protocol for EtherNet/IP | No |
| Supporting protocol for AS-Interface Safety at Work | No |
| Supporting protocol for DeviceNet Safety | No |
| Supporting protocol for INTERBUS-Safety | No |
| Supporting protocol for PROFIsafe | No |
| Supporting protocol for SafetyBUS p | No |
| Supporting protocol for other bus systems | Yes |
| Radio standard Bluetooth | No |
| Radio standard WLAN 802.11 | No |
| Radio standard GPRS | No |
| Radio standard GSM | No |
| Mobile communications standard 3G (UMTS) | No |
| System accessory | Yes |
| Type of electric connection | Flat plug-in connection |
| With potential separation | Yes |
| With power supply module | Yes |
| Suitable as segment module | Yes |
| Remote module | No |
| Fieldbus connection over separate bus coupler possible | Yes |
| Bus diagnosis possible | No |
| Suitable for rail mounting | Yes |
| Wall mounting/direct mounting | Yes |
| Front built-in possible | No |
| Rack-assembly possible | No |
| Suitable for safety functions | No |
| SIL according to IEC 61508 | None |
| Performance level according to EN ISO 13849-1 | None |
| Appendant operation agent (Ex ia) | No |
| Country of origin | Germany |