Kont.m Darw DILM7-38 2DI (DIL-SWD-32-001)
Eaton

Kont.m Darw DILM7-38 2DI

Part numberDIL-SWD-32-001EAN / GTIN4015081168309HS code8538.90
MOQ:1

Pricing

Request a quote

We reply within 24 hours

Overview

Eaton Kont.m Darw DILM7-38 2DI (part number DIL-SWD-32-001) is listed under Control & Automation / I/O Modules. Sales unit: pcs; Package quantity: 5 pcs; Eaton catalogue number: 118560; Depth: 72 mm; Height: 38 mm; Width: 45 mm.

Technical Specifications

Manufacturer part number (MPN)
DIL-SWD-32-001
EAN / GTIN
4015081168309
Sales unit
pcs
Package quantity
5 pcs
Eaton catalogue number
118560
Depth
72 mm
Height
38 mm
Width
45 mm
Weight
0.04 kg
Certifications
CSA File No.: 2324643; CSA Class No.: 3211-07; CSA-C22.2 No. 14-05; UL; UL File No.: E29184; CSA; IEC/EN 61131-2; UL Category Control No.: NKCR; CE; EN 50178; IEC/EN 60947; IEC/EN 60947-4-1; UL 508
Constant acceleration
1 g, 8.4 - 150 Hz, according to IEC/EN 61131-2, Vibrations
Constant amplitude
3,5 mm, 5 - 8.4 Hz, according to IEC/EN 61131-2, Vibrations
Drop and topple
50 mm Drop height, Drop to IEC/EN 60068-2-31
Height of fall (IEC/EN 60068-2-32) - max
0.3 m
Mounting position
As DILM7 to DILM38
Shock resistance
15 g, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 11 ms, 9 Impacts
Ambient operating temperature - max
60 °C
Ambient storage temperature - max
70 °C
Ambient operating temperature - min
-25 °C
Environmental conditions
Condensation: prevent with appropriate measures
Relative humidity
5 - 95 % (non-condensing, IEC/EN 60068-2-30)
Addressing
Address set automatically
Connection to SmartWire-DT
Yes
Connection type
Push in terminals
Auxiliary contact; SWD
Plug, 8-pole; External device plug SWD4-8SF2-5, SmartWire-DT
LED indicator
Status indication of SmartWire-DT network: Green and orange LED
Station
SmartWire-DT slave, SmartWire-DT network
Number of auxiliary contacts
2
Static heat dissipation, non-current-dependent Pvs
0.8 W
Rated operational voltage
15 V DC (auxiliary contact)
Supply voltage at DC - max
15 VDC
Supply voltage at DC - min
15 VDC
Air discharge
8 kV, according to IEC 61131-2, level 3, ESD
Burst impulse
1 kV, Signal cable, according to IEC/EN 61131-2, Level 3; 1 kV, SmartWire-DT cable, according to IEC/EN 61131-2, Level 3
Contact discharge
4 kV, according to IEC/EN 61131-2, Level 2, ESD
Electromagnetic fields
1 V/m at 2.0 - 2.7 GHz (according to IEC/EN 61131-2:2008); 10 V/m at 80 - 1000 MHz (according to IEC/EN 61131-2:2008); 3 V/m at 1.4 - 2 GHz (according to IEC/EN 61131-2:2008)
Radiated RFI
10 V (IEC/EN 61131-2:2008, Level 3)
Radio interference class
Class A (EN 55011)
Electric connection type
Spring clamp connection
Features
Fieldbus connection over separate bus coupler possible; Fieldbus connection over separate bus coupler possible
Fitted with
Own supply
Functions
Contactor actuation; Display of Switch status Contactor, status of the digital inputs 1 and 2; For connecting the contactors to SmartWire-DT
Cable length
≤ 2.8 m, Connection auxiliary contact
Current consumption
40 mA, SmartWire-DT network
Degree of protection
IP20
Input current at signal 1
3 mA
Number of inputs (digital)
2
Number of outputs (digital)
1
Output current
0.5 A
Overvoltage category
II
Pollution degree
2
Product category
SmartWire-DT slave
Protocol
Other bus systems
Type
SWD contactor modules
Voltage type
DC
Pick-up current
500 mA (for DILM 17-38); 188 mA (for DILM 12-15); 125 mA (for DILM 7-9)
Sealing current
125 mA, SmartWire-DT network for DILM 7-9; 21 mA, SmartWire-DT network for DILM 17-38; 188 mA, SmartWire-DT network for DILM 12-15
Power consumption
3 W for DILM 7-9 (Pick-up power); 4.5 W for DILM 12-15 (Pick-up power); 4.5 W for DILM 12-15 (Sealing power); 12 W for DILM 17-38 (Pick-up power); 3 W for DILM 7-9 (Sealing power); 0.5 W for DILM 17-38 (Sealing power)
Explosion safety category for dust
None
Explosion safety category for gas
None
Potential isolation
Connection auxiliary contact: no
Terminal capacity
0.2 - 1.5 mm² (24 - 16 AWG), solid; 0.25 - 1.5 mm², flexible with ferrule
Certified for UL hazardous location division 1
No
Certified for UL hazardous location division 2
No
Certified for UL hazardous location group A (acetylene)
No
Certified for UL hazardous location group B (hydrogen)
No
Certified for UL hazardous location group C (ethylene)
No
Certified for UL hazardous location group D (propane)
No
Certified for UL hazardous location group E (metal dusts)
No
Certified for UL hazardous location class I
No
Certified for UL hazardous location class II
No
Certified for UL hazardous location class III
No
Supporting protocol for EtherCAT
No
Supply voltage DC
15 V
Number of digital inputs
2
Number of digital outputs
1
Digital inputs configurable
No
Digital outputs configurable
No
Permitted voltage at input
15 V
Type of voltage (input voltage)
DC
Permitted voltage at output
20.4–28.8 V
Type of output voltage
DC
Short-circuit protection, outputs available
No
Number of HW-interfaces other
1
With optical interface
No
Supporting protocol for TCP/IP
No
Supporting protocol for PROFIBUS
No
Supporting protocol for CAN
No
Supporting protocol for INTERBUS
No
Supporting protocol for ASI
No
Supporting protocol for KNX
No
Supporting protocol for Modbus
No
Supporting protocol for Data-Highway
No
Supporting protocol for DeviceNet
No
Supporting protocol for SUCONET
No
Supporting protocol for LON
No
Supporting protocol for PROFINET IO
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for SERCOS
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for other bus systems
Yes
Radio standard Bluetooth
No
Radio standard WLAN 802.11
No
Radio standard GPRS
No
Radio standard GSM
No
Mobile communications standard 3G (UMTS)
No
IO link master
No
System accessory
Yes
Type of electric connection
Spring clamp connection
Time delay at signal change
10–84 ms
Fieldbus connection over separate bus coupler possible
Yes
Suitable for rail mounting
No
Wall mounting/direct mounting
No
Front built-in possible
No

Standards & Compliance

HS Code
8538.90

Cross References

  • EAN 4015081168309
  • SAP 1000288955
  • Code 81038261

Product Documentation

Document preview: Kont.m Darw DILM7-38 2DI (DIL-SWD-32-001) — Specification Data Sheet (OEM)

Catalogue entry last verified: 2026-09-29. A manufacturer datasheet is attached to this entry — confirm application-critical values against it.

Frequently asked questions

Where can I buy DIL-SWD-32-001?
DIL-SWD-32-001 can be ordered from cballast.com as a Eaton catalogue item: request a quotation on this page or email sales@cballast.com, and the order ships worldwide.
What is the manufacturer part number for this Eaton product?
The manufacturer part number is DIL-SWD-32-001.
What is the HS code for DIL-SWD-32-001?
The customs tariff (HS) code for DIL-SWD-32-001 is 8538.90.
Who manufactures DIL-SWD-32-001?
DIL-SWD-32-001 is a Eaton product in the Control & Automation range.
Is a datasheet available for DIL-SWD-32-001?
Yes — the DIL-SWD-32-001 datasheet can be viewed and downloaded on this page.
What is the minimum order quantity for DIL-SWD-32-001?
The minimum order quantity is 1.
Is DIL-SWD-32-001 available?
Yes — DIL-SWD-32-001 is available to order: fulfilment is from supplier stock in cBallast's European network, dispatched directly from the warehouse to the customer, with the exact lead time stated in the quotation (reply within 24 hours).