Motor protection relay ZE-12
Eaton

Motor protection relay ZE-12

Part numberZE-12EAN / GTIN4015080147527HS code8536.30
MOQ:1

Pricing

Request a quote

We reply within 24 hours

Product Description

Eaton ZE-12 Motor Protection Relay, Ir= 9 - 12 A, 1 N/O, 1 N/C, direktemontasje.

Technical Specifications

Manufacturer part number (MPN)
ZE-12
EAN / GTIN
4015080147527
Sales unit
pcs
Eaton catalogue number
014752
Depth
52 mm
Height
65 mm
Width
45 mm
Weight
0.078 kg
Certifications
IEC/EN 60947; VDE 0660; CE; CSA; IEC/EN 60947-5-1; UL; CSA Class No.: 3211-03; CSA-C22.2 No. 14; IEC/EN 60947-4-1; UL Category Control No.: NKCR; UL File No.: E29184; CSA File No.: 012528; UL 508
Number of auxiliary contacts (change-over contacts)
0
Number of auxiliary contacts (normally closed contacts)
1
Number of auxiliary contacts (normally open contacts)
1
Number of contacts (normally closed contacts)
1
Number of contacts (normally open contacts)
1
Equipment heat dissipation, current-dependent Pvid
4.2 W
Heat dissipation per pole, current-dependent Pvid
1.4 W
Rated operational current for specified heat dissipation (In)
12 A
Conventional thermal current Ith of auxiliary contacts (1-pole, open)
6 A
Rated operational current (Ie) at AC-15, 120 V
1.5 A
Rated operational current (Ie) at AC-15, 220 V, 230 V, 240 V
1.5 A
Rated operational current (Ie) at AC-15, 380 V, 400 V, 415 V
0.7 A
Rated operational current (Ie) at AC-15, 500 V
0.5 A
Rated operational current (Ie) at DC-13, 110 V
0.4 A
Rated operational current (Ie) at DC-13, 220 V, 230 V
0.2 A
Rated operational current (Ie) at DC-13, 24 V
0.9 A
Rated operational current (Ie) at DC-13, 60 V
0.75 A
Rated operational voltage (Ue) - max
690 V
Safe isolation
300 V AC, Between main circuits, According to EN 61140; 250 V AC, Between auxiliary contacts, According to EN 61140; 300 V AC, Between auxiliary contacts and main contacts, According to EN 61140
Switching capacity (auxiliary contacts, general use)
1.5 A, 240V AC, (UL/CSA); 0.6 A, 600V AC, (UL/CSA)
Switching capacity (auxiliary contacts, pilot duty)
D300, AC operated (UL/CSA); R300, DC operated (UL/CSA)
Voltage rating - max
600 VAC
Features
Phase-failure sensitivity (according to IEC/EN 60947, VDE 0660 Part 102); Trip-free release; Reset pushbutton manual/auto; Test/off button
Ambient operating temperature - max
50 °C
Ambient operating temperature - min
-25 °C
Ambient operating temperature (enclosed) - max
40 °C
Ambient operating temperature (enclosed) - min
-25 °C
Class
CLASS 10 A / IEC 60947-4-1, 8.2.1.5.1.1. c) 4 min
Climatic proofing
Damp heat, constant, to IEC 60068-2-78; Damp heat, cyclic, to IEC 60068-2-30
Degree of protection
IP20; IP00
Mounting method
Direct attachment; Direct mounting
Overload release current setting - max
12 A
Overload release current setting - min
9 A
Overvoltage category
III
Pollution degree
3
Product category
ZE overload relays for mini contactor relays
Protection
Finger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274)
Rated impulse withstand voltage (Uimp)
4000 V (auxiliary and control circuits); 6000 V AC
Shock resistance
10 g, Mechanical, Sinusoidal, Shock duration 10 ms
Suitable for
Branch circuits, (UL/CSA)
Temperature compensation
≤ 0.25 %/K, residual error for T > 40°; Continuous
Short-circuit current rating (basic rating)
15 A, max. CB, CB for max. 480 V, SCCR (UL/CSA); 45 A, max. Fuse, SCCR (UL/CSA); 5 kA, SCCR (UL/CSA); 16 A, max. CB, CB for max. 480 V, SCCR (UL/CSA)
Short-circuit protection rating
Max. 4 A gG/gL, Fuse, Auxiliary contacts; 20 A gG/gL, Fuse, Type “2” coordination; 35 A gG/gL, Fuse, Type “1” coordination; Information on Type "1" and Type"2" coordination applies to 100 kA and 690 V
Screw size
M3.5, Terminal screw
Screwdriver size
2, Terminal screw, Pozidriv screwdriver; 0.8 x 5.5 mm, Terminal screw, Standard screwdriver
Stripping length (control circuit cable)
8 mm
Stripping length (main cable)
8 mm
Terminal capacity (flexible with ferrule)
2 x (0.5 - 1.5) mm², Main cables; 1 x (0.5 - 1.5) mm², Main cables; 1 x (0.5 - 1.5) mm², Control circuit cables
Terminal capacity (solid)
1 x (0.75 - 2.5) mm², Control circuit cables; 2 x (0.75 - 2.5) mm², Control circuit cables; 1 x (0.75 - 2.5) mm², Main cables
Terminal capacity (solid/stranded AWG)
2 x (18 - 12), Control circuit cables; 18 - 14, Main cables
Tightening torque
1.2 Nm, Screw terminals
Number of auxiliary contacts as normally open contact
1
Number of auxiliary contacts as normally closed contact
1
Release class
CLASS 10
Type of electrical connection of main circuit
Screw connection
Max. rated operation voltage Ue
690 V
Adjustable current range
9–12 A
Reset function input
No
Reset function automatic
Yes
Reset function push-button
Yes
Country of origin
Germany

Standards & Compliance

HS Code
8536.30

Cross References

  • EAN 4015080147527
  • SAP 1200310315
  • Code 82297530

Product Documentation

Document preview: Motor protection relay, — Specification Data Sheet (OEM)

Catalogue entry last verified: 2026-09-29. A manufacturer datasheet is attached to this entry — confirm application-critical values against it.

Frequently asked questions

Where can I buy ZE-12?
ZE-12 can be ordered from cballast.com as a Eaton catalogue item: request a quotation on this page or email sales@cballast.com, and the order ships worldwide.
What is the manufacturer part number for this Eaton product?
The manufacturer part number is ZE-12.
What is the HS code for ZE-12?
The customs tariff (HS) code for ZE-12 is 8536.30.
Who manufactures ZE-12?
ZE-12 is a Eaton product in the Switchgear & Protection range.
Is a datasheet available for ZE-12?
Yes — the ZE-12 datasheet can be viewed and downloaded on this page.
What is the minimum order quantity for ZE-12?
The minimum order quantity is 1.
Is ZE-12 available?
Yes — ZE-12 is available to order: fulfilment is from supplier stock in cBallast's European network, dispatched directly from the warehouse to the customer, with the exact lead time stated in the quotation (reply within 24 hours).