
Eaton
Residual Current Circuit Breaker G/B 25A/4/30MA
Part number167892EAN / GTIN4015081644681HS code8536.90
Electrical Components
RCDs & RCBOs
MOQ:1
Pricing
Request a quote
We reply within 24 hours
Product Description
Eaton 167892 FRCdM-25/4/003-G/B Digital residual current circuit breaker. B type can is used in all nettsystemer.
Technical Specifications
- Manufacturer part number (MPN)
- 167892
- EAN / GTIN
- 4015081644681
- HS code
- 8536.90
- Sales unit
- pcs
- Package quantity
- 30 pcs
- Eaton catalogue number
- 167892
- Depth
- 76 mm
- Height
- 80 mm
- Width
- 70 mm
- Weight
- 0.32 kg
- Compliances
- RoHS conform
- Certifications
- IEC/EN 61008; IEC/EN 62423; ÖVE E 8601; EN45545-2; IEC 61373
- Features
- Residual current circuit-breakers, digital; Additional equipment possible; Selective protection
- Fitted with
- Interlocking device
- Functions
- Short-time delayed tripping
- Used with
- Residual current circuit-breakers, digital; FRCdM; Type G/B (ÖVE E 8601)
- Amperage Rating
- 25 A
- Application
- xEffect - Switchgear for industrial and advanced commercial applications
- Fault current rating
- 30 mA
- Impulse withstand current
- 3 kA (8/20 μs) surge-proof
- Number of poles
- Four-pole
- Rated short-circuit strength
- 10 kA
- Sensitivity type
- All current sensitive
- Tripping time
- 10 ms delayed; Short time-delayed
- Type
- FRCdM Residual current circuit-breakers, digital Type G/B (ÖVE E 8601)
- Ambient operating temperature - max
- 60 °C
- Ambient operating temperature - min
- -25 °C
- Equipment heat dissipation, current-dependent
- 4.6 W
- Heat dissipation capacity
- 4.6 W
- Heat dissipation per pole, current-dependent
- 0 W
- Rated operational current for specified heat dissipation (In)
- 25 A
- Static heat dissipation, non-current-dependent
- 0 W
- Admissible back-up fuse
- 63 A gG/gL
- Admissible back-up fuse overload - max
- 25 A gG/gL
- Frequency rating
- 50 Hz
- Leakage current type
- B
- Lifespan, electrical
- 4000 operations
- Pollution degree
- 2
- Rated fault current - max
- 0.03 A
- Rated fault current - min
- 0.03 A
- Rated impulse withstand voltage (Uimp)
- 4 kV
- Rated insulation voltage (Ui)
- 440 V
- Rated operational voltage (Ue) - max
- 415 V
- Rated residual making and breaking capacity
- 500 A
- Rated short-time withstand current (Icw)
- 10 kA
- Short-circuit rating
- 63 A (max. admissible back-up fuse)
- Surge current capacity
- 3 kA
- Test circuit range
- 196 V AC - 264 V AC
- Voltage rating - max
- 456 VAC
- Voltage rating - min
- 50 VAC
- Voltage rating (IEC/EN 60947-2)
- 240 V AC / 415 V AC
- Switching capacity of auxiliary contact - min
- 10 μA, 10 mV DC
- Switching current of auxiliary contact - max
- 2 A
- Switching duty with resistive load of auxiliary contact - max
- 60 W
- Switching voltage at AC of auxiliary contact - max
- 240 V
- Switching voltage at DC of auxiliary contact - max
- 220 V
- Terminal capacity of auxiliary contact
- 0.25 mm² - 1.5 mm²
- Built-in depth
- 70.5 mm
- Built-in width (number of units)
- 70 mm (4 SU)
- Busbar material thickness
- 0.8 mm - 2 mm
- Climatic proofing
- 25-55 °C / 90-95% relative humidity according to IEC 60068-2
- Connectable conductor cross section (multi-wired) - max
- 16 mm²
- Connectable conductor cross section (multi-wired) - min
- 1.5 mm²
- Connectable conductor cross section (solid-core) - max
- 35 mm²
- Connectable conductor cross section (solid-core) - min
- 1.5 mm²
- Contact position indicator color
- Red / green
- Degree of protection
- IP20; IP20, IP40 with suitable enclosure
- Frame
- 45 mm
- Lifespan, mechanical
- 20000 operations
- Mounting Method
- DIN rail; Quick attachment with 2 latch positions for DIN-rail IEC/EN 60715
- Mounting position
- As required
- Permitted storage and transport temperature - max
- 60 °C
- Permitted storage and transport temperature - min
- -35 °C
- Status indication
- White / blue
- Terminal capacity (cable)
- M5 (with cross-recessed screw as defined in EN ISO 4757-Z2, PZ2)
- Terminal capacity (solid wire)
- 1.5 mm² - 35 mm²
- Terminal capacity (stranded cable)
- 16 mm² (2x)
- Terminal protection
- Finger and hand touch safe, DGUV VS3, EN 50274
- Terminals (top and bottom)
- Twin-purpose terminals
- Tightening torque
- 2 Nm - 2.4 Nm
- Width in number of modular spacings
- 4
Standards & Compliance
- HS Code
- 8536.90
Cross References
- EAN 4015081644681
- SAP 1000694931
- Code 8623025
Product Documentation
Document preview: RESIDUAL CURRENT CIRCUIT BREAKER G/B 25A/4/30MA (167892) — Specification Data Sheet (OEM)
More from Eaton

Eaton
Residential Distribution Board G2 SideBySide 6-Row 106 mm
EP-501124

Eaton
Residential Distribution Board IT 50A 14 Circuits
1728148

Eaton
Eaton NZMN2-VE250-BT Molded-Case Circuit Breaker 3-Pole 250A 50KA

Eaton
Load-break switch 125A 3P
276288

Eaton
Locking bracket, unit breaker
ZV7-11-BE

Eaton
Busbar 3P+N 1M 16mm²
1657123

Eaton
Contact element 1TO FRONT
M22-K01

Eaton
Digital Astro time switch, 1 channel
196850
Catalogue entry last verified: 2026-09-30. A manufacturer datasheet is attached to this entry — confirm application-critical values against it.
Frequently asked questions
- Where can I buy 167892?
- 167892 can be ordered from cballast.com as a Eaton catalogue item: request a quotation on this page or email sales@cballast.com, and the order ships worldwide.
- What is the manufacturer part number for this Eaton product?
- The manufacturer part number is 167892.
- What is the HS code for 167892?
- The customs tariff (HS) code for 167892 is 8536.90.
- Who manufactures 167892?
- 167892 is a Eaton product in the Electrical Components range.
- Is a datasheet available for 167892?
- Yes — the 167892 datasheet can be viewed and downloaded on this page.
- What is the minimum order quantity for 167892?
- The minimum order quantity is 1.
- Is 167892 available?
- Yes — 167892 is available to order: fulfilment is from supplier stock in cBallast's European network, dispatched directly from the warehouse to the customer, with the exact lead time stated in the quotation (reply within 24 hours).
