Star-delta switch (T3-4-3/I2)
Eaton

Star-delta switch (T3-4-3/I2)

Part numberT3-4-3/I2EAN / GTIN4015082229061HS code8536.90
Switchgear & Protection
Disconnect Switches
MOQ:1

Pricing

Request a quote

We reply within 24 hours

Product Description

Eaton T3-4-3/I2 Y/D-selector switch. Enclosed - 7,5 / 18.5 / 22 / 22 kW AC-1 32A.

Technical Specifications

Manufacturer part number (MPN)
T3-4-3/I2
EAN / GTIN
4015082229061
HS code
8536.90
Sales unit
pcs
Eaton catalogue number
222906
Depth
181 mm
Height
127 mm
Width
100 mm
Weight
0.594 kg
Compliances
CE Marked
Certifications
CSA Std. C22.2 No. 14-05; UL 508; EN 60947-3; IEC 60947; VDE; IEC/EN 60204; CSA; IEC/EN 60947; UL File No.: E36332; CE; CSA-C22.2 No. 94; UL Category Control No.: NLRV; IEC/EN 60947-3; UL; CSA File No.: 012528; CSA Class No.: 3211-07; CSA-C22.2 No. 60947-4-1-14; UL 60947-4-1; VDE 0660
Catalog Notes
Rated Short-time Withstand Current (Icw) for a time of 1 second
Actuator function
Maintained; With 0 (Off) position
Actuator type
Short thumb-grip
Ambient operating temperature - max
40 °C
Ambient operating temperature - min
-25 °C
Ambient operating temperature (enclosed) - max
40 °C
Ambient operating temperature (enclosed) - min
-25 °C
Climatic proofing
Damp heat, constant, to IEC 60068-2-78; Damp heat, cyclic, to IEC 60068-2-30
Control circuit reliability
1 failure per 100,000 switching operations statistically determined, at 24 V DC, 10 mA)
Number of auxiliary contacts (change-over contacts)
0
Number of auxiliary contacts (normally closed contacts)
0
Number of auxiliary contacts (normally open contacts)
0
Number of contacts
8
Equipment heat dissipation, current-dependent Pvid
0 W
Heat dissipation capacity Pdiss
0 W
Heat dissipation per pole, current-dependent Pvid
1.1 W
Rated operational current for specified heat dissipation (In)
32 A
Static heat dissipation, non-current-dependent Pvs
0 W
Rated breaking capacity at 220/230 V (cos phi to IEC 60947-3)
260 A
Rated breaking capacity at 400/415 V (cos phi to IEC 60947-3)
260 A
Rated breaking capacity at 500 V (cos phi to IEC 60947-3)
240 A
Rated breaking capacity at 660/690 V (cos phi to IEC 60947-3)
170 A
Rated operational current (Ie)
32 A at AC-3, 500 V star-delta; 25.5 A at AC-3, 690 V star-delta; 32 A at AC-3, 400 V star-delta; 32 A at AC-3, 230 V star-delta
Rated operational current (Ie) at AC-21, 440 V
32 A
Rated operational current (Ie) at AC-23A, 230 V
32 A
Rated operational current (Ie) at AC-23A, 400 V, 415 V
32 A
Rated operational current (Ie) at AC-23A, 500 V
26.4 A
Rated operational current (Ie) at AC-23A, 690 V
17 A
Rated operational current (Ie) at AC-3, 220 V, 230 V, 240 V
23.7 A
Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V
23.7 A
Rated operational current (Ie) at AC-3, 500 V
23.7 A
Rated operational current (Ie) at AC-3, 660 V, 690 V
14.7 A
Rated operational current (Ie) at DC-13, control switches L/R = 50 ms
20 A
Rated operational current (Ie) at DC-21, 240 V
1 A
Rated operational current (Ie) at DC-23A, 120 V
12 A
Rated operational current (Ie) at DC-23A, 24 V
25 A
Rated operational current (Ie) at DC-23A, 240 V
5 A
Rated operational current (Ie) at DC-23A, 48 V
25 A
Rated operational current (Ie) at DC-23A, 60 V
25 A
Rated operational power at AC-23A, 220/230 V, 50 Hz
7.5 kW
Rated operational power at AC-23A, 400 V, 50 Hz
15 kW
Rated operational power at AC-23A, 500 V, 50 Hz
15 kW
Rated operational power at AC-23A, 690 V, 50 Hz
15 kW
Rated operational power at AC-3, 380/400 V, 50 Hz
18.5 kW
Rated operational power at AC-3, 415 V, 50 Hz
11 kW
Rated operational power at AC-3, 690 V, 50 Hz
11 kW
Rated operational power star-delta at 220/230 V, 50 Hz
7.5 kW
Rated operational power star-delta at 380/400 V, 50 Hz
15 kW
Rated operational power star-delta at 500 V, 50 Hz
18.5 kW
Rated operational power star-delta at 690 V, 50 Hz
22 kW
Rated operational voltage (Ue) at AC - max
690 V
Rated uninterrupted current (Iu)
32 A
Uninterrupted current
Rated uninterrupted current Iu is specified for max. cross-section.
Enclosure material
Plastic
Features
Complete device in housing
Fitted with
0 (off) position; Black thumb grip and front plate
Inscription
0-Y-D
Number of poles
3
Accessories
Black thumb grip and front plate
Degree of protection
NEMA 12; IP65; NEMA 1
Degree of protection (front side)
IP65; NEMA 12
Lifespan, mechanical
500,000 Operations
Model
Star-delta switch
Mounting method
Surface mounting
Mounting position
As required
Number of contact units
4
Operating frequency
1200 Operations/h
Overvoltage category
III
Pollution degree
3
Product Category
Control switches
Rated impulse withstand voltage (Uimp)
6000 V AC
Safe isolation
440 V AC, Between the contacts, According to EN 61140
Safety parameter (EN ISO 13849-1)
B10d values as per EN ISO 13849-1, table C.1
Shock resistance
12 g, Mechanical, According to IEC/EN 60068-2-27, Half-sinusoidal shock 20 ms
Suitable for
Ground mounting; Branch circuits, suitable as motor disconnect, (UL/CSA); Front mounting
Switching angle
60 °
Type
Star-delta switch
Assigned motor power at 115/120 V, 60 Hz, 1-phase
1.5 HP
Assigned motor power at 200/208 V, 60 Hz, 1-phase
3 HP
Assigned motor power at 200/208 V, 60 Hz, 3-phase
3 HP
Assigned motor power at 230/240 V, 60 Hz, 1-phase
3 HP
Assigned motor power at 230/240 V, 60 Hz, 3-phase
3 HP
Assigned motor power at 460/480 V, 60 Hz, 3-phase
7.5 HP
Assigned motor power at 575/600 V, 60 Hz, 3-phase
10 HP
Rated conditional short-circuit current (Iq)
1 kA
Rated short-time withstand current (Icw)
650 A, Contacts, 1 second
Short-circuit current rating (basic rating)
5 kA, SCCR (UL/CSA); 40A, max. Fuse, SCCR (UL/CSA)
Short-circuit current rating (high fault)
10 kA, SCCR (UL/CSA); 40 A, Class J, max. Fuse, SCCR (UL/CSA)
Short-circuit protection rating
35 A gG/gL, Fuse, Contacts
Load rating
1.6 x Iₑ (with intermittent operation class 12, 40 % duty factor); 2 x Iₑ (with intermittent operation class 12, 25 % duty factor); 1.3 x Iₑ (with intermittent operation class 12, 60 % duty factor)
Number of contacts in series at DC-21A, 240 V
1
Number of contacts in series at DC-23A, 120 V
3
Number of contacts in series at DC-23A, 24 V
1
Number of contacts in series at DC-23A, 240 V
5
Number of contacts in series at DC-23A, 48 V
2
Number of contacts in series at DC-23A, 60 V
3
Rated making capacity up to 690 V (cos phi to IEC/EN 60947-3)
320 A
Switching capacity (auxiliary contacts, general use)
10A, IU, (UL/CSA)
Switching capacity (auxiliary contacts, pilot duty)
A600 (UL/CSA); P600 (UL/CSA)
Switching capacity (main contacts, general use)
25 A, Rated uninterrupted current max. (UL/CSA)
Voltage per contact pair in series
60 V
Screw size
M4, Terminal screw
Terminal capacity (flexible with ferrule)
1 x (0.75 - 4) mm², ferrules to DIN 46228; 2 x (0.75 - 4) mm², ferrules to DIN 46228
Terminal capacity (solid/flexible with ferrule AWG)
14 - 10
Terminal capacity (solid/stranded)
1 x (1 - 6) mm²; 2 x (1 - 6) mm²
Tightening torque
1.6 Nm, Screw terminals; 17.7 lb-in, Screw terminals

Standards & Compliance

HS Code
8536.90

Cross References

  • EAN 4015082229061
  • SAP 1000040747
  • Code 8795731

Product Documentation

Document preview: Stjerne-trekant switch (T3-4-3/I2) — Specification Data Sheet (OEM)

Catalogue entry last verified: 2026-09-30. A manufacturer datasheet is attached to this entry — confirm application-critical values against it.

Frequently asked questions

Where can I buy T3-4-3/I2?
T3-4-3/I2 can be ordered from cballast.com as a Eaton catalogue item: request a quotation on this page or email sales@cballast.com, and the order ships worldwide.
What is the manufacturer part number for this Eaton product?
The manufacturer part number is T3-4-3/I2.
What is the HS code for T3-4-3/I2?
The customs tariff (HS) code for T3-4-3/I2 is 8536.90.
Who manufactures T3-4-3/I2?
T3-4-3/I2 is a Eaton product in the Switchgear & Protection range.
Is a datasheet available for T3-4-3/I2?
Yes — the T3-4-3/I2 datasheet can be viewed and downloaded on this page.
What is the minimum order quantity for T3-4-3/I2?
The minimum order quantity is 1.
Is T3-4-3/I2 available?
Yes — T3-4-3/I2 is available to order: fulfilment is from supplier stock in cBallast's European network, dispatched directly from the warehouse to the customer, with the exact lead time stated in the quotation (reply within 24 hours).