Danfoss SAVD safety pressure reduction controller, PN 25, DN 32, Kvs 12.5 m³/h, 3 – 12 bar setting, external thread G 1 3/4 A (003H6702)
Danfoss

Danfoss SAVD safety pressure reduction controller, PN 25, DN 32, Kvs 12.5 m³/h, 3 – 12 bar setting, external thread G 1 3/4 A

Part number003H6702Item numberCB-DANF-003H6702EAN / GTIN5702421542231HS code8481.80
MaterialValve body Ductile iron EN-GJS-400-18-LT (GGG 40.3); valve cone dezincing-free brass CuZn36Pb2As; seat stainless steel, mat. No. 1.4571; control diaphragm + DP sealing EPDM
HVAC & Refrigeration
Balancing Valves
MOQ:1

Pricing

Request a quote

We reply within 24 hours

Product Description

Danfoss SAVD (003H6702) — self-acting safety pressure reduction controller, PN 25, DN 32, for district heating and central heating systems. The SAVD is a safety pressure reduction controller that needs no external power or control signal; the setpoint is set on the actuator spring and the reduced/relieved pressure is sensed through an impulse line to the control diaphragm. It is normally open and closes progressively as the downstream (outlet) pressure rises, holding the reduced pressure at or below the setpoint to protect equipment against over-pressure. Pressure setting range 3 – 12 bar adjustable; Kvs 12.5 m³/h; maximum differential-pressure range 16 bar; media temperature 2–150 °C; cavitation factor z ≥ 0.6; seat leakage 0.05 % Kvs (IEC 60534). Valve body Ductile iron EN-GJS-400-18-LT (GGG 40.3); valve cone dezincing-free brass CuZn36Pb2As; seat stainless steel 1.4571; control diaphragm EPDM. External-thread connection G 1 3/4 A (ISO 228/1) via tailpieces (tailpiece/union-nut set ordered separately). Media: district heating/cooling circulation water (glycolic water up to 30%), pH 7–10. Mounting version Free; stem position Normally open. OEM P/N 003H6702. EAN 5702421542231. Technical data quoted verbatim from store.danfoss.com (code 003H6702).

Technical Specifications

Code number
003H6702
Type
SAVD
Product group
Pressure and flow controllers (safety pressure controller)
Function
Self-acting safety pressure reduction controller (SAV) — normally open, closes on rising downstream pressure to hold a limited reduced (outlet) pressure
Valve size
DN 32
Pressure class
PN 25
Connection
External thread G 1 3/4 A (ISO 228/1), via tailpieces
Kvs value
12.5 m³/h
Pressure setting range
3 – 12 bar (adjustable)
Max. differential pressure range
16 bar
Media temperature
2 – 150 °C
Media pH
7 – 10
Cavitation factor z
≥ 0.6
Seat leakage rate
0.05 % Kvs (IEC 60534)
Mounting version
Free
Stem position
Normally open
Number of ports
2
Permissible media
District heating/cooling circulation water (glycolic water up to 30%)
Valve body material
Ductile iron EN-GJS-400-18-LT (GGG 40.3)
Valve cone material
Dezincing free brass CuZn36Pb2As
Valve seat material
Stainless steel, mat. No. 1.4571
Actuator diaphragm
EPDM
EU RoHS compliance
Yes with exemptions (6(c))
REACH Candidate List substance
Lead (CAS no. 7439-92-1)
China RoHS
Out of scope
Net weight
10.053 kg
Gross weight
10.053 kg
EAN
5702421542231
HS code
8481.80

Standards & Compliance

Material
Valve body Ductile iron EN-GJS-400-18-LT (GGG 40.3); valve cone dezincing-free brass CuZn36Pb2As; seat stainless steel, mat. No. 1.4571; control diaphragm + DP sealing EPDM
Pressure Rating
PN 25 (max. differential-pressure range 16 bar)
Temperature Range
2 to 150 °C (district heating/cooling water); glycolic water up to 30%
HS Code
8481.80

Compatibility & Fitment

Danfoss SAVD for DN 32 district-heating/central-heating circuits at PN 25 where automatic over-pressure protection is required by limiting the reduced downstream pressure. Set the reduction setpoint within 3 – 12 bar; for a different band use the lower-range SAVD. Size the valve by the design flow against Kvs 12.5 m³/h. Confirm the connection (External thread G 1 3/4 A (ISO 228/1), via tailpieces) and pressure class (PN 25) match the pipework; order the matching tailpiece/union-nut set and impulse tube separately. Maximum differential-pressure range 16 bar, media temperature up to 150 °C. For pressure RELIEF use the SAVA; for combined differential-pressure and flow control use the AVPQ.

Not sure if it fits? Email sales@cballast.com with your equipment serial number or photos — we confirm fit before you order.

Product Documentation

Document preview: Danfoss 003H6702 — OEM Product Page

Catalogue entry last verified: 2026-08-24. A manufacturer datasheet is attached to this entry — confirm application-critical values against it.

Frequently asked questions

Where can I buy 003H6702?
003H6702 can be ordered from cballast.com as a Danfoss catalogue item: request a quotation on this page or email sales@cballast.com, and the order ships worldwide.
What is the manufacturer part number for this Danfoss product?
The manufacturer part number is 003H6702.
What is the HS code for 003H6702?
The customs tariff (HS) code for 003H6702 is 8481.80.
Who manufactures 003H6702?
003H6702 is a Danfoss product in the HVAC & Refrigeration range.
Is a datasheet available for 003H6702?
Yes — the 003H6702 datasheet can be viewed and downloaded on this page.
What is the minimum order quantity for 003H6702?
The minimum order quantity is 1.
Is 003H6702 available?
Yes — 003H6702 is available to order: fulfilment is from supplier stock in cBallast's European network, dispatched directly from the warehouse to the customer, with the exact lead time stated in the quotation (reply within 24 hours).