Danfoss AVPQ differential pressure & flow controller, PN 16, DN 25, kVS 8 m³/h, Δp 0.2 – 1.0 bar adjustable, flow 0.1 – 6 m³/h, external thread G 1 ¼ A (003H6487)
Danfoss

Danfoss AVPQ differential pressure & flow controller, PN 16, DN 25, kVS 8 m³/h, Δp 0.2 – 1.0 bar adjustable, flow 0.1 – 6 m³/h, external thread G 1 ¼ A

Part number003H6487Item numberCB-DANF-003H6487EAN / GTIN5702421540060HS code8481.80
MaterialValve body red bronze CuSn5ZnPb (Rg5); valve cone dezincing-free brass CuZn36Pb2As; seat stainless steel 1.4571; control diaphragms EPDM
HVAC & Refrigeration
Balancing Valves
MOQ:1

Pricing

Request a quote

We reply within 24 hours

Product Description

Danfoss AVPQ (003H6487) — self-acting differential pressure and flow controller, PN 16, DN 25, for district heating and central heating systems. The AVPQ combines a control valve with an adjustable flow restrictor and an actuator with two control diaphragms; it closes on rising differential pressure or when the set maximum flow is exceeded, holding both a stable differential pressure across the controlled circuit and a limited maximum flow so connected control valves keep their authority. Differential-pressure setting 0.2 – 1.0 bar adjustable via handle; kVS 8 m³/h; flow rate 0.1 – 6 m³/h. Maximum differential-pressure range 12 bar, media temperature 2–150 °C, cavitation factor z ≥ 0.6, leakage 0.02 % kVs. Valve body red bronze CuSn5ZnPb (Rg5), valve cone dezincing-free brass CuZn36Pb2As, seat stainless steel 1.4571, control diaphragms EPDM. Connection external thread G 1 ¼ A (ISO 228/1) via tailpieces (ordered separately); supplied complete with compression fittings for Ø6 mm copper impulse tube. Media: district heating/cooling circulation water; glycolic water up to 30%. OEM P/N 003H6487. Technical data quoted verbatim from the Danfoss AVPQ/AVPQ-F data sheet and store.danfoss.com (code 003H6487). differential-pressure range 12 bar); Temperature range: 2 – 150 °C (heating/cooling water); glycolic water up to 30%; HS code: 8481.80. Used in commercial refrigeration, provision-room cooling and reefer plant rooms across HFC, HFO and CO2 (R744) refrigerants.

Technical Specifications

Code number
003H6487
Type
AVPQ
Product group
Pressure flow controllers
Function
Differential pressure and flow controller (self-acting)
Description
Self-acting differential pressure control and flow limiter (district heating), adjustable setting
Valve size
DN 25
Pressure class
PN 16
Connection
External thread G 1 ¼ A (ISO 228/1), via tailpieces
kVS value
8 m³/h
Flow rate [m³/h]
0.1 – 6
Differential pressure setting
0.2 – 1.0 bar (adjustable, factory range)
Flow-restrictor differential pressure (dpb)
0.2 bar
Max. differential pressure range
12 bar
Media temperature
2 – 150 °C
Cavitation factor z
≥ 0.6
Leakage rate
0.02 % kVs
Stem position
Normally open
Mounting version
Return
Permissible media
District heating/cooling circulation water; glycolic water (≤30%)
Valve body material
Red bronze CuSn5ZnPb (Rg5)
Valve cone material
Dezincing-free brass CuZn36Pb2As
Valve seat material
Stainless steel, mat. no. 1.4571
Control diaphragm
EPDM
EU RoHS compliance
Yes with exemptions (6(c))
REACH Candidate List substance
Lead (CAS no. 7439-92-1)
China RoHS compliance
Out of scope
Net weight
3.29 kg
Gross weight
3.29 kg
EAN
5702421540060
HS code
8481.80

Standards & Compliance

Material
Valve body red bronze CuSn5ZnPb (Rg5); valve cone dezincing-free brass CuZn36Pb2As; seat stainless steel 1.4571; control diaphragms EPDM
Pressure Rating
PN 16 (max. differential-pressure range 12 bar)
Temperature Range
2 – 150 °C (heating/cooling water); glycolic water up to 30%
HS Code
8481.80

Compatibility & Fitment

Danfoss AVPQ for DN 25 district-heating or central-heating circuits where BOTH differential pressure and maximum flow must be held. Size by the branch design flow (0.1 – 6 m³/h here, kVS 8) and set the differential-pressure setpoint within 0.2 – 1.0 bar. Confirm the connection (external thread G 1 ¼ A, ISO 228/1) and pressure class (PN 16) match the pipework; order the matching tailpiece/union-nut set separately (impulse-tube compression fittings are included). For differential-pressure control without flow limitation use the AVP; for flow limitation via a combined valve+limiter without integrated Δp handle use the AVPB. Maximum differential-pressure range 12 bar, media temperature 2–150 °C.

Not sure if it fits? Email sales@cballast.com with your equipment serial number or photos — we confirm fit before you order.

Product Documentation

Document preview: Danfoss AVPQ / AVPQ-F self-acting differential pressure & flow controller — Data Sheet

Catalogue entry last verified: 2026-08-29. A manufacturer datasheet is attached to this entry — confirm application-critical values against it.

Frequently asked questions

Where can I buy 003H6487?
003H6487 can be ordered from cballast.com as a Danfoss catalogue item: request a quotation on this page or email sales@cballast.com, and the order ships worldwide.
What is the manufacturer part number for this Danfoss product?
The manufacturer part number is 003H6487.
What is the HS code for 003H6487?
The customs tariff (HS) code for 003H6487 is 8481.80.
Who manufactures 003H6487?
003H6487 is a Danfoss product in the HVAC & Refrigeration range.
Is a datasheet available for 003H6487?
Yes — the 003H6487 datasheet can be viewed and downloaded on this page.
What is the minimum order quantity for 003H6487?
The minimum order quantity is 1.
Is 003H6487 available?
Yes — 003H6487 is available to order: fulfilment is from supplier stock in cBallast's European network, dispatched directly from the warehouse to the customer, with the exact lead time stated in the quotation (reply within 24 hours).