Danfoss AVP differential pressure controller, PN 16, DN 15, kVS 4 m³/h, Δp 0.05 – 0.5 bar adjustable, external thread G 3/4 A, flow mounting (003H6240)
Danfoss

Danfoss AVP differential pressure controller, PN 16, DN 15, kVS 4 m³/h, Δp 0.05 – 0.5 bar adjustable, external thread G 3/4 A, flow mounting

Part number003H6240Item numberCB-DANF-003H6240EAN / GTIN5702421537268HS code8481.80
MaterialValve body red bronze CuSn5ZnPb (Rg5); valve seat stainless steel 1.4571; valve cone dezincing free brass CuZn36Pb2As; control diaphragm EPDM
HVAC & Refrigeration
Balancing Valves
MOQ:1

Pricing

Request a quote

We reply within 24 hours

Product Description

Danfoss AVP (003H6240) — self-acting differential pressure controller, PN 16, DN 15, for mounting in the flow pipe, for district heating and central heating systems. The AVP closes on rising differential pressure, holding a stable differential pressure across the controlled circuit so that connected control valves keep their authority. It consists of a control valve and an actuator with one control diaphragm and a handle for differential-pressure setting. Unlike the AVPB, the AVP is a differential-pressure controller only (no integrated flow limiter). kVS 4 m³/h; differential-pressure setting range 0.05 – 0.5 bar, adjustable via handle. Maximum differential pressure 12 bar; medium temperature 2–150 °C; leakage 0.02% of kVS (IEC 534). Valve body red bronze CuSn5ZnPb (Rg5), valve seat stainless steel 1.4571, valve cone dezincing free brass CuZn36Pb2As, control diaphragm EPDM. Connection external thread G 3/4 A (ISO 228/1), via tailpieces (ordered separately). Media: circulation water / glycolic water up to 30% (pH 7–10). OEM P/N 003H6240, EAN 5702421537268. Technical data quoted verbatim from the Danfoss AVP / AVP-F (PN 16) data sheet and store.danfoss.com (code 003H6240). differential pressure 12 bar); Temperature range: 2 – 150 °C (medium); HS code: 8481.80. Used in commercial refrigeration, provision-room cooling and reefer plant rooms across HFC, HFO and CO2 (R744) refrigerants.

Technical Specifications

Code number
003H6240
Type
AVP
Product group
Pressure and flow controllers
Description
Self-acting differential pressure controller (district heating), adjustable setting, flow mounting
Valve size
DN 15
Pressure class
PN 16
kVS value
4 m³/h
Connection
external thread G 3/4 A (ISO 228/1)
Differential pressure setting
0.05 – 0.5 bar (adjustable)
Max. differential pressure
12 bar
Application
District Heating
Medium
Circulation water / glycolic water up to 30% (pH 7–10)
Medium temperature
2 – 150 °C
Leakage (IEC 534)
0.02% of kVS
Mounting version
Flow
Stem position
Normally open
Valve body
Red bronze CuSn5ZnPb (Rg5)
Valve seat
Stainless steel, mat. No. 1.4571
Valve cone
Dezincing free brass CuZn36Pb2As
Control diaphragm / sealing
EPDM
EU RoHS compliance
Yes with exemptions (6(c))
REACH Candidate List substance
Lead (CAS no. 7439-92-1)
Net weight
1.977 Kilogram
Gross weight
1.977 Kilogram
Packed volume
4.484 Liter
EAN
5702421537268
HS code
8481.80

Standards & Compliance

Material
Valve body red bronze CuSn5ZnPb (Rg5); valve seat stainless steel 1.4571; valve cone dezincing free brass CuZn36Pb2As; control diaphragm EPDM
Thread Standard
ISO 228/1
Pressure Rating
PN 16 (max. differential pressure 12 bar)
Temperature Range
2 – 150 °C (medium)
HS Code
8481.80

Compatibility & Fitment

Danfoss AVP for DN 15 district-heating or central-heating circuits, PN 16, flow-pipe mounting. Size by the branch design flow (kVS 4 m³/h) and set the differential-pressure setpoint within 0.05 – 0.5 bar. Confirm the connection (external thread G 3/4 A (ISO 228/1)) and pressure class (PN 16) match the pipework; order the matching tailpiece/union-nut set and impulse tube separately. For combined differential-pressure control and flow limiting use the AVPB/AVPQ instead. Maximum differential pressure 12 bar, medium temperature up to 150 °C.

Not sure if it fits? Email sales@cballast.com with your equipment serial number or photos — we confirm fit before you order.

Product Documentation

Document preview: Danfoss AVP / AVP-F (PN 16) differential pressure controller — Data Sheet

Catalogue entry last verified: 2026-08-29. A manufacturer datasheet is attached to this entry — confirm application-critical values against it.

Frequently asked questions

Where can I buy 003H6240?
003H6240 can be ordered from cballast.com as a Danfoss catalogue item: request a quotation on this page or email sales@cballast.com, and the order ships worldwide.
What is the manufacturer part number for this Danfoss product?
The manufacturer part number is 003H6240.
What is the HS code for 003H6240?
The customs tariff (HS) code for 003H6240 is 8481.80.
Who manufactures 003H6240?
003H6240 is a Danfoss product in the HVAC & Refrigeration range.
Is a datasheet available for 003H6240?
Yes — the 003H6240 datasheet can be viewed and downloaded on this page.
What is the minimum order quantity for 003H6240?
The minimum order quantity is 1.
Is 003H6240 available?
Yes — 003H6240 is available to order: fulfilment is from supplier stock in cBallast's European network, dispatched directly from the warehouse to the customer, with the exact lead time stated in the quotation (reply within 24 hours).