Danfoss AVP-F differential pressure controller, PN 16, DN 32, kVS 10 m³/h, Δp 0.2 bar fixed, external thread G 1 ¾ A (003H6223)
Danfoss

Danfoss AVP-F differential pressure controller, PN 16, DN 32, kVS 10 m³/h, Δp 0.2 bar fixed, external thread G 1 ¾ A

Part number003H6223Item numberCB-DANF-003H6223EAN / GTIN5702421537534HS code8481.80
MaterialValve body red bronze CuSn5ZnPb (Rg 5); valve seat stainless steel 1.4571; valve cone dezincing-free brass CuZn36Pb2As; control diaphragm EPDM
HVAC & Refrigeration
Balancing Valves
MOQ:1

Pricing

Request a quote

We reply within 24 hours

Product Description

Danfoss AVP-F (003H6223) — self-acting differential pressure controller with a fixed, factory-preset setpoint, PN 16, DN 32, for district heating and central heating systems. The AVP-F holds a stable differential pressure across the controlled circuit so that connected control valves keep their authority; unlike the adjustable AVP it has a fixed (non-adjustable) setting of 0.2 bar and no adjustment handle, giving a tamper-proof, permanently set Δp. Unlike the AVPB it is a differential-pressure controller only (no integrated flow limiter). It consists of a control valve and an actuator with one control diaphragm. kVS 10 m³/h; fixed differential-pressure setting 0.2 bar. Maximum differential pressure 12 bar; medium temperature 2–150 °C; leakage 0.05% of kVS (IEC 534). Valve body red bronze CuSn5ZnPb (Rg 5), valve seat stainless steel 1.4571, valve cone dezincing-free brass CuZn36Pb2As, control diaphragm EPDM. Connection external thread G 1 ¾ A (ISO 228/1) via tailpieces (ordered separately). Media: circulation water / glycolic water up to 30% (pH 7–10). OEM P/N 003H6223. Technical data quoted verbatim from the Danfoss AVP / AVP-F (PN 16) data sheet and store.danfoss.com (code 003H6223). differential pressure 12 bar); Temperature range: 2 – 150 °C (medium); HS code: 8481.80. Used in commercial refrigeration, provision-room cooling and reefer plant rooms across HFC, HFO and CO2 (R744) refrigerants.

Technical Specifications

Code number
003H6223
Type
AVP-F
Product group
Pressure and flow controllers
Description
Self-acting differential pressure controller (district heating), fixed factory setting, non-adjustable
Valve size
DN 32
Pressure class
PN 16
kVS value
10 m³/h
Connection
External thread G 1 ¾ A (ISO 228/1), via tailpieces
Differential pressure setting
0.2 bar (fixed, factory-set — non-adjustable)
Max. differential pressure
12 bar
Medium
Circulation water / glycolic water up to 30% (pH min. 7, max. 10)
Medium temperature
2 – 150 °C
Leakage (IEC 534)
0.05% of kVS
Mounting version
Return or flow pipe
Valve body
Red bronze CuSn5ZnPb (Rg 5)
Valve seat
Stainless steel, mat. No. 1.4571
Valve cone
Dezincing-free brass CuZn36Pb2As
Control diaphragm / sealing
EPDM
EU RoHS compliance
Yes with exemptions (6(c))
REACH Candidate List substance
Lead (CAS no. 7439-92-1)
Net weight
2.206 kg
Gross weight
2.206 kg
EAN
5702421537534
HS code
8481.80

Standards & Compliance

Material
Valve body red bronze CuSn5ZnPb (Rg 5); valve seat stainless steel 1.4571; valve cone dezincing-free brass CuZn36Pb2As; control diaphragm EPDM
Pressure Rating
PN 16 (max. differential pressure 12 bar)
Temperature Range
2 – 150 °C (medium)
HS Code
8481.80

Compatibility & Fitment

Danfoss AVP-F for DN 32 district-heating or central-heating circuits where a permanent, tamper-proof differential-pressure setpoint is required. Size by the branch design flow (kVS 10 m³/h); the setpoint is fixed at 0.2 bar and cannot be field-adjusted — select the code that matches the required Δp. Confirm the connection (external thread G 1 ¾ A, ISO 228/1) and pressure class (PN 16) match the pipework; order the matching tailpiece/union-nut set and impulse tube separately. For a field-adjustable setpoint use the AVP; for combined differential-pressure control and flow limiting use the AVPB instead. Maximum differential pressure 12 bar, medium temperature up to 150 °C.

Not sure if it fits? Email sales@cballast.com with your equipment serial number or photos — we confirm fit before you order.

Product Documentation

Document preview: Danfoss AVP / AVP-F (PN 16) differential pressure controller — Data Sheet

Catalogue entry last verified: 2026-08-29. A manufacturer datasheet is attached to this entry — confirm application-critical values against it.

Frequently asked questions

Where can I buy 003H6223?
003H6223 can be ordered from cballast.com as a Danfoss catalogue item: request a quotation on this page or email sales@cballast.com, and the order ships worldwide.
What is the manufacturer part number for this Danfoss product?
The manufacturer part number is 003H6223.
What is the HS code for 003H6223?
The customs tariff (HS) code for 003H6223 is 8481.80.
Who manufactures 003H6223?
003H6223 is a Danfoss product in the HVAC & Refrigeration range.
Is a datasheet available for 003H6223?
Yes — the 003H6223 datasheet can be viewed and downloaded on this page.
What is the minimum order quantity for 003H6223?
The minimum order quantity is 1.
Is 003H6223 available?
Yes — 003H6223 is available to order: fulfilment is from supplier stock in cBallast's European network, dispatched directly from the warehouse to the customer, with the exact lead time stated in the quotation (reply within 24 hours).