Barrier Glands — IEC 60079-14 Rules & Hawke ICG 653

Reference compiled by cBallast. 14-page PDF; the full content is on this page.
Brand
Hawke
Subject
Hazardous-area cable entries
Document type
Reference
Reference
2026 edition
Issued
2026-11-23
Pages
14
Format
Web page and PDF

Whether a flameproof (Ex d) enclosure takes a compression gland or a barrier gland is decided by IEC 60079-14, and the rule has been rewritten twice: the 2 litre selection chart used to 2007 and kept alive in UK practice by HSE notice HID 1-2016, the 2013 cable-construction and 3 metre rule, and the 2024 flowchart with its normative Annex C cable pressure test. This reference sets the three rule sets side by side as decision tables, works six cases through all of them, and then specifies the barrier answer in Hawke's range — the ICG 653/UNIV by size, core limits, compound, BFOU sizing arithmetic, inspection points and article number, with the conversion kits that turn an installed dual-marked 501/453/UNIV into a barrier gland.

Published by cballast.com. Last reviewed November 2026. Standards content is drawn from the published contents and forewords of IEC 60079-14, the IEC SC 31J supporting document SD 001:2022, HSE safety notice HID 1-2016, the national foreword of BS EN IEC 60079-14:2024 and published summaries of the 2024 edition. Product figures are from Hawke International's current specification sheet and assembly instructions for the ICG 653/UNIV. The edition of the standard in force on the site and the instruction sheet packed with the gland always govern. In brief. A flameproof enclosure is built to contain an explosion inside it. The cable is the one part of that containment the enclosure maker does not supply. Whether a cable may enter through a gland that seals on its inner sheath, or must enter through a barrier gland that seals around the individual cores with a setting compound, is decided by the installation standard, IEC 60079-14, and the rule has been rewritten twice: a selection chart from 1996 to 2007, a cable-construction and 3 m rule in 2013, and a flowchart with a normative cable pressure test in 2024. The United Kingdom kept the chart as a national annex and its regulator told duty holders to go on using it. This reference sets the editions side by side as decision tables, works six cases through all of them, and then gives the data needed to specify the barrier answer in Hawke's range, the ICG 653/UNIV: sizes, core limits, compounds, a sizing table for NEK TS 606 BFOU cable, inspection points and the cballast article number for every size and material.

1. Key facts

2. Two glands, one job

A flameproof enclosure does not keep gas out. It lets an internal ignition happen and prevents the flame from reaching the atmosphere outside. Every opening is therefore a designed flame path, and a cable entry has two of them: past the gland's seal, and through the cable itself.

PropertyFlameproof gland with elastomeric sealing ring (compression gland)Barrier gland
Inner sealA ring or diaphragm compressed onto the cable's inner sheathA two-part compound filling the space between and around the individual cores
What the flame path through the cable depends onThe cable's own construction: fillers, bedding, compactnessThe compound; the cable's interstices are closed at the gland
CertificationIEC 60079-1, as equipment, marking Ex db (usually also Ex eb)IEC 60079-1, as equipment, marking Ex db (usually also Ex eb)
AssemblyMechanicalMechanical, plus mixing or injecting compound, inspecting it, and letting it cure before energising
Size limitsInner and outer sheath diameter rangesOuter sheath range, maximum inner sheath, maximum diameter over cores, maximum number of cores
Re-terminationThe gland can be re-made on the cableThe cured compound is permanent; re-terminating needs a new compound kit
Hawke types501/453/UNIV and 501/453/RAC for armoured cable; 501/421 for unarmoured cableICG 653/UNIV for armoured cable, and for unarmoured cable to assembly instruction AI 2040

What the research behind the standard established is recorded in IEC SC 31J's supporting document SD 001:2022, *Background to flameproof cable gland requirements in IEC 60079-14*:

Finding in SD 001:2022Consequence
Flame can pass by the gland seal or through the cable, including the gaps between cores and fillersThe cable's construction is part of the flameproof joint when a compression gland is used
Damage to the bedding under the seal from pressure or heat "might lead to flame transmission" in later ignitionsTransmissions in the test record often occurred only after multiple ignitions, which is why the tests use repeated explosions
"There is insufficient evidence to suggest that flame transmission could occur through the gaps between strands"; the conductors are thought to quench a flame as an arrestor doesThe barrier is made around cores, not inside them
"Flame transmission is also fundamentally different to gas or liquid transmission", which "could occur even through the strands of an individual conductor"A gland that stops flame is not, by that fact, a gas-migration seal; where gas or liquid migration along a cable matters it is addressed separately
In later test work "the extent of 'gaps' in a cable" was the prime criterionThe 2013 and 2024 rules moved from enclosure properties to cable properties

A point that is easy to miss: a gland's certification tests are made on test mandrels, not on the cable the installer will use. The certificate proves the gland. Only the installation standard addresses the combination of gland and cable, which is why the standard, not the certificate, carries the selection rule.

The standard also recognises entries that avoid the question: indirect entry through an increased-safety (Ex e) terminal chamber, mineral-insulated cable with its own flameproof gland, and flameproof sealing devices such as sealing chambers. This reference covers direct entry of sheathed cable, where the choice between the two glands arises.

3. The rule in each edition

EditionPublishedWhereRule for direct cable entry into Ex dDecided by
11984—No requirement for compound-sealed glands—
21996Selection chartRequirement for compound-sealed glands introduced, drawn largely from ERA report 3051/85 (United Kingdom, April 1976)Ignition source, gas group, zone, enclosure volume
42007Clause 10.4.2, Figure 1Same chartIgnition source, gas group, zone, enclosure volume
5November 2013Clause 10.6.2; cable in 9.3.2(a); informative Annex EChart removed. Barrier gland, or sealing-ring gland on a qualifying cable at least 3 m longCable construction and cable length
630 August 2024Clauses 7.4.3 and 7.5.7, Figure 2, normative Annex CFlowchartGas group, cable length, enclosure volume, cable test evidence

Which edition applies is a matter of jurisdiction and contract:

WherePosition in November 2026
IEC and IECEx-based projectsEdition 6 is the current edition
EU and EEA (EN IEC 60079-14:2024)Approved 4 October 2024; latest date of national publication 4 July 2025; EN 60079-14:2014 withdrawn by 4 October 2027. Both are in circulation until then
United KingdomBS EN IEC 60079-14:2024 published 31 August 2026 with a National Annex NA; BS EN 60079-14:2014 is withdrawn on 4 October 2027; HSE notice HID 1-2016 remains published
Operator and project specificationsFrequently stricter than any edition, for example barrier glands on all IIC and hydrogen service

4. 1996 to 2007: the selection chart

The chart applies to cable that is sheathed with thermoplastic, thermosetting or elastomeric material, is substantially compact and circular, has extruded bedding, and whose fillers, if any, are non-hygroscopic. Any other cable goes to a barrier gland or a sealing device without entering the chart. For a qualifying cable the chart asks four questions in order:

1. Internal source of ignition in the enclosure?2. Gas requires IIC equipment?3. Zone 1?4. Enclosure volume above 2 dm³?Entry
No———Flameproof gland with sealing ring
YesYes——Barrier gland or sealing device
YesNoNo (Zone 2)—Flameproof gland with sealing ring
YesNoYesNoFlameproof gland with sealing ring
YesNoYesYesBarrier gland or sealing device

Internal sources of ignition are sparks or equipment temperatures occurring in normal operation that can cause ignition. An enclosure containing terminals only, or an indirect-entry enclosure, is treated as having none.

The chart's evidence base is described in SD 001:2022. It rests on ERA report 3051/85, *Flameproof Enclosures: The Integrity of Cable/Cable Gland Inlet Assemblies* (April 1976), which tested tape-bedded and extruded cables mainly on 60-litre enclosures, using repeated explosions to stress the cable and gland. The supporting document observes that "there are no reported tests for flame transmission using less than 60-litre enclosures", and that the work treated severe cable damage as an indication of possible flame transmission, "a critical assumption that was not fully examined." Later work by PTB and Dekra with a 40-litre enclosure and multiple ignitions could not reproduce the original failures and concluded that the gaps in the cable were what mattered. That conclusion produced the 2013 rule.

5. 2013: cable construction and three metres

Edition 5 removed the chart. Clause 10.6.2 offers, for sheathed cable entering directly:

OptionRequirement
(a)Barrier cable glands in compliance with IEC 60079-1 and certified as equipment
(b)Cable glands in compliance with IEC 60079-1, certified as equipment, combined with cables complying with 9.3.2(a) and with a minimum length of connected cable of 3 m

A cable complying with 9.3.2(a) is sheathed with thermoplastic, thermosetting or elastomeric material, is circular and compact, has extruded bedding or sheath, and has non-hygroscopic fillers if it has fillers at all.

Three effects followed.

  1. Enclosure properties dropped out. Gas group, zone, volume and the presence of an ignition source no longer mattered. A compression gland became permissible on a large IIC enclosure with arcing contacts in Zone 1, provided the cable qualified and was 3 m long.
  2. Every flameproof enclosure came in. The rule applies to junction boxes with terminals only, which the chart had exempted. A 1 m tail between two boxes now needs a barrier gland at both ends, or a different entry method.
  3. The burden moved to the cable. The installer has to know the cable's construction, and an informative annex (Annex E) described a test of the cable's openness.

SD 001:2022 records that the 3 m minimum "was proposed as being conservative", "possibly many times the minimum cable length required to control flame transmission". Its test table shows why length matters at all: in 2016 tests with 450 mm of cable outside the enclosure, flame transmission was recorded in 4 of 22 entries, and the note against them reads "Subsequent tests in 2017 with longer cable lengths of 1.5m were successful (i.e. no flame transmission)." Length, gas group and cable construction interact, which is the background to the 2024 rewrite.

6. The United Kingdom position

DateDocumentWhat it says
2014BS EN 60079-14:2014Implements Edition 5, and reproduces the earlier selection chart as Figure 1 of an informative National Annex. HSE quotes the UK committee as "unclear as to the justification for this change"
1 February 2016HSE safety notice HID 1-2016, *Use of Barrier Glands in Potentially Explosive Atmospheres to meet IEC 60079-14:2013 (Edition 5)*HSE classes the National Annex as an established standard; duty holders "should therefore apply the Informative National Annex of BS EN 60079-14: 2014 as Relevant Good Practice" when deciding whether to fit a barrier gland. Addressed to chemical processing, engineering, warehousing and offshore, including COMAH operators
31 August 2026BS EN IEC 60079-14:2024Implements Edition 6. The national foreword records that the UK committee voted against approval of the European standard, citing its treatment of extra-low-voltage circuits for earthing and equipotential bonding, advises users to consult BS 7671, and draws attention to a National Annex NA "which provides further guidance"
4 October 2027BS EN 60079-14:2014Withdrawn

HSE's stated reasons in 2016 were that no documented test evidence had been seen to justify removing the chart, that the tests behind the change addressed ignition through the cable while repeated explosions inside an enclosure can damage insulation and bedding, and that HSE held independent third-party evidence supporting the UK committee's view.

For a UK site the working position during the transition is: read the site's own engineering standard first; where it follows HSE's notice, the chart in section 4 is applied in addition to the edition being worked to; and National Annex NA of the 2024 British Standard is read before a compression gland is accepted on a flameproof enclosure. A barrier gland satisfies the chart, the 2013 rule and the 2024 flowchart at once.

7. 2024: the flowchart and the Annex C cable test

Edition 6 was restructured into design (clause 6), selection (clause 7), installation (clause 8) and initial inspection (clause 9), and its title now reads *Electrical installation design, selection and installation of equipment, including initial inspection*. For flameproof entries the relevant parts are clause 7.4.3, *Cables for direct entries into flameproof enclosures*; clause 7.5.7, *Cable entry device for Type of Protection "d"*; Figure 2, *Selection of cable entry devices*; and Annex C (normative), *Pressure test procedure for cables into Ex "d" enclosures*, with sections on test apparatus, test method and test report. Restricted-breathing enclosures have their own clauses (7.4.4 and 7.5.8).

The Chair of IEC TC 31 summarised the change in November 2024: the flowchart brings together "the use of hydrogen, cable lengths of the connecting cable or enclosures with a volume ≤ 2 000 cm3", and the Annex C test is applied where the cable length is more than 3 m in the IIC and hydrogen groups, or more than 0.5 m where the rated enclosure volume is above 2,000 cm³. Read together with a certification body's published walk-through of Figure 2, the logic is:

Gas groupConnected cable lengthEnclosure volumeEvidence that the cable passes Annex CEntry device
IIC, or IIB + H2Under 3 mAnyNot relevantBarrier gland (sealing around the cores)
IIC, or IIB + H23 m or moreAnyYesGland with elastomeric seal permitted
IIC, or IIB + H23 m or moreAnyNoBarrier gland
IIA, IIBUnder 0.5 mAnyNot relevantBarrier gland
IIA, IIB0.5 m or more2,000 cm³ or lessNot requiredGland with elastomeric seal permitted
IIA, IIB0.5 m or moreAbove 2,000 cm³, or not knownYesGland with elastomeric seal permitted
IIA, IIB0.5 m or moreAbove 2,000 cm³, or not knownNoBarrier gland

This table is a reading of published summaries, not a reproduction of the standard. Figure 2 and clauses 7.4.3 and 7.5.7 are the authority, including for the exact treatment of the boundary values and for the cable construction requirements that sit ahead of the flowchart.

Three things about Annex C matter to a specifier.

  1. It is normative. The cable test of the 2013 edition was informative. Where the flowchart calls for evidence, the evidence is now part of compliance.
  2. Its purpose is narrow. In the TC 31 Chair's words the test "is solely to assist a user in the determination of the type of Ex "d" cable entry device (that is, with elastomeric seal or sealing around the cores) which can be used into an Ex "d" enclosure", and it "does not prove that the cable is 'gas tight' or 'flameproof'".
  3. It is a property of a cable type. The evidence is a test report for the specific cable construction. It is requested from the cable maker with the cable, filed with the gland schedule, and its absence sends the entry to a barrier gland.

8. Six cases through three rule sets

Each case assumes a cable that is circular and compact with extruded bedding and non-hygroscopic fillers, unless stated. "Compression" means a flameproof gland with elastomeric sealing ring. The 2024 column follows the published summaries in section 7.

CaseChart (to 2007; UK practice under HID 1-2016)2013 rule2024 flowchart
1. Starter enclosure with contactors, IIB, Zone 1, 8 litres, 25 m of cableBarrier: ignition source, Zone 1, above 2 dm³Compression permitted: qualifying cable, over 3 mCompression only with Annex C evidence for the cable; otherwise barrier
2. Switch housing with contacts, 0.4 litre, hydrogen service (IIC), Zone 1, 15 m of cableBarrier: ignition source and IICCompression permittedCompression only with Annex C evidence; otherwise barrier
3. Control station with pushbutton contacts, IIA, Zone 2, 1.5 litres, 1.2 m tail from an adjacent boxCompression: Zone 2Barrier: tail under 3 mCompression permitted: over 0.5 m, volume not above 2,000 cm³
4. Junction box, terminals only, IIB, Zone 1, 5 litres, 10 m of cableCompression: no internal ignition sourceCompression permittedCompression only with Annex C evidence; otherwise barrier
5. Analyser enclosure with ignition-capable parts, IIC, Zone 1, 2 m of cableBarrierBarrier: under 3 mBarrier: IIC and under 3 m
6. Any enclosure; cable with tape bedding, hygroscopic fillers or an open, poorly filled lay-upBarrier or sealing device: cable is outside the chartBarrier: cable fails 9.3.2(a)Barrier is the entry that does not depend on the cable's construction

The three rule sets agree on cases 5 and 6 and disagree on cases 1 to 4. A site that must satisfy more than one of them, which describes most UK sites and any project built to both an operator specification and the current standard, converges on the barrier gland wherever any column says barrier.

9. When a barrier gland is the specified answer

ConditionRule set that requires it
Hydrogen or other IIC gas, enclosure with an internal source of ignitionChart
Zone 1, enclosure above 2 dm³ with an internal source of ignitionChart
Connected cable shorter than 3 m, any gas group2013
Connected cable shorter than 3 m in IIC or IIB + H2; shorter than 0.5 m in IIA or IIB2024
IIC or IIB + H2, no Annex C evidence for the cable2024
Enclosure above 2,000 cm³ or of unknown volume, no Annex C evidence for the cable2024
Cable not circular and compact, tape-bedded, or with hygroscopic fillersChart, 2013
Cable construction unknown, or cable not yet selected when glands are orderedAll, as the only entry that is certain to comply
Operator specification calling for barrier glands on a service or areaContract

Separately from the selection rules, Hawke states the ICG 653/UNIV's application as sealing around the individual cores on cables with cold-flow characteristics, cables that are not effectively filled, cables with hygroscopic fillers and cables containing fibre-optic cores. Cold flow is the movement of a cable's sheath under the compressive force of a gland seal; low-smoke and fire-resistant cables usually show it. A barrier seal does not depend on compressing the inner sheath.

10. The Hawke ICG 653/UNIV: data

ItemValue
TypeBarrier cable gland for armoured cable; used on unarmoured cable to assembly instruction AI 2040
MarkingEx db IIC Gb; Ex eb IIC Gb; Ex nR IIC Gc; Ex tb IIIC Db
CertificatesATEX CML 18ATEX1268X; IECEx CML 18.0131X; UKEX CML 21UKEX1132X. Ex nR: CML 19ATEX4507X; IECEx CML 21.0012X; CML 21UKEX4133X
North AmericacCSAus 1024328; Class I Division 1 Groups A, B, C, D; Class I Zone 1 AEx db IIC Gb and AEx eb IIC Gb
Marine type approvalsABS 19-LD1876514-1-PDA; BV 43523/B0; DNV TAE0000BS
StandardsIEC/EN 60079-0, -1, -7, -15, -31; IEC/EN 62444 (anchorage type D)
Operating temperature−60 to +80 °C
Ingress protectionIP66, IP67, IP68, IP69 to IEC 60529; NEMA 4X. IP68 is 30 m for 7 days with thread sealant, or 10 m for 24 hours without it on sizes Os to C
Impact and delugeIK10 to IEC 62262; deluge protection to DTS01
MaterialsBrass, nickel-plated brass, 316L stainless steel
Entry threadsMetric, 1.5 mm pitch, 15 mm thread length as standard; NPT options
ArmourReversible clamp ring for wire armour, braid and tape; alternative ring for intermediate thicknesses
BarrierTransparent elastomeric compound pot, inspectable; ExPress injectable resin as standard, QSP hand-mixed putty by adding Q to the part string
Schedule of limitationsCompound cross-section at least 20% of the total area over a depth of 20 mm; in increased-safety use the entry thread is sealed to maintain the enclosure's ingress rating
Field identificationRed deluge boot (the 501/453/UNIV has a black one)

Sizes and limits:

SizeMetric entryNPT optionsMax. coresMax. fibre-optic coresMax. Ø over cores (mm)Max. Ø inner sheath (mm)Outer sheath min–max (mm)Across flats (mm)
OsM20½"12488.08.1 (10.0 with QSP putty)5.5–12.024
OM20½"12488.811.79.5–16.024
AM20¾" or ½"157210.814.012.5–20.530
BM251" or ¾"3014415.919.916.9–26.036
CM321¼" or 1"42—21.926.222.0–33.046
C2M401½" or 1¼"60—26.732.328.0–41.055
DM502" or 1½"80—37.744.236.0–52.665
EM632½" or 2"100—49.056.046.0–65.380
FM753" or 2½"120—59.868.057.0–78.095

An M16 entry is available on the smallest sizes and reduces the maximum diameter over cores to 7 mm. Armour acceptance follows the 501/453 family: with the standard ring, 0.8–1.25 mm or 0–0.8 mm on sizes Os to A, 1.25–1.6 or 0–0.7 mm on B, 1.6–2.0 or 0–0.7 mm on C and C2, and 1.8–2.5 or 0–1.0 mm on D to F, by ring orientation; the alternative ring (suffix R) covers 0.9–1.25 or 0.5–0.9 mm on B, 1.2–1.6 or 0.6–1.2 mm on C and C2, and 1.45–1.8 or 1.0–1.45 mm on D to F.

The part string is built as type, size, thread, material, then options: 653U C M32 is a size C gland with an M32 entry in brass; NP denotes nickel-plated brass; R the alternative armour ring; Q the QSP putty in place of ExPress resin. NPT threads are written as decimals (1.25 for 1¼").

11. Sizing a barrier gland: four checks, not two

A compression gland is sized on two diameters. A barrier gland adds two limits that come from the compound pot, and on multi-core and larger power cable they are often the limits that decide the size.

CheckMeasured on the cableCompared with
1. Overall diameterOver the outer sheathOuter sheath min–max of the size
2. Inner sheathOver the bedding, under the armourMaximum inner sheath of the size
3. Core bundleOver the laid-up cores after stripping the inner sheath and removing fillers and tapesMaximum diameter over cores of the size
4. Core countEvery insulated coreMaximum cores of the size
ThenArmour type and thicknessClamp ring orientation, or the alternative ring

The table below applies those limits to the nominal dimensions one cable maker (Prysmian, BFOU 0.6/1 kV to NEK TS 606) publishes for halogen-free offshore power and control cable. The cable maker does not publish the diameter over cores, so the table shows the arithmetic the installer needs: the bundle limit of the first size that accepts the sheath dimensions and core count, how much smaller than the inner-sheath diameter the bundle must therefore be, and the next size where one accepts the overall diameter. The bundle is smaller than the diameter over the inner sheath by twice the bedding thickness. Where the required reduction is greater than that, the larger size is the one to order.

Cores × mm²Ø over inner sheath (mm)Overall Ø (mm)First size by sheaths and core countIts bundle limit (mm)Bundle must be smaller than the inner-sheath Ø by at least (mm)Next size that accepts the overall Ø, with its bundle limit
2 × 1.510.013.0O (M20)8.81.2A (M20), 10.8
2 × 2.510.514.0O (M20)8.81.7A (M20), 10.8
3 × 1.510.513.5O (M20)8.81.7A (M20), 10.8
3 × 2.511.314.8O (M20)8.82.5A (M20), 10.8
3 × 412.516.0A (M20)10.81.7none
3 × 613.517.5A (M20)10.82.7B (M25), 15.9
3 × 1015.519.5B (M25)15.9none: the bundle always fits—
3 × 1618.022.0B (M25)15.92.1C (M32), 21.9
3 × 2521.924.6C (M32)21.9none: the bundle always fits—
3 × 3524.128.6C (M32)21.92.2C2 (M40), 26.7
3 × 5027.532.5C2 (M40)26.70.8none
3 × 7032.037.5C2 (M40)26.75.3D (M50), 37.7
3 × 9537.043.0D (M50)37.7none: the bundle always fits—
4 × 1.511.315.0O (M20)8.82.5A (M20), 10.8
4 × 2.512.516.0A (M20)10.81.7none
4 × 413.517.5A (M20)10.82.7B (M25), 15.9
4 × 615.018.5B (M25)15.9none: the bundle always fits—
4 × 1017.320.6B (M25)15.91.4none
4 × 1620.024.0C (M32)21.9none: the bundle always fits—
4 × 2524.327.0C (M32)21.92.4none
4 × 3526.831.5C2 (M40)26.70.1none
4 × 5030.535.5C2 (M40)26.73.8none
4 × 7035.541.0D (M50)37.7none: the bundle always fits—
7 × 1.513.517.0A (M20)10.82.7B (M25), 15.9
7 × 2.514.618.5B (M25)15.9none: the bundle always fits—
12 × 1.517.622.1B (M25)15.91.7C (M32), 21.9
12 × 2.519.523.5B (M25)15.93.6C (M32), 21.9
19 × 1.520.524.5C (M32)21.9none: the bundle always fits—
19 × 2.522.927.7C (M32)21.91.0none
27 × 2.527.933.3C2 (M40)26.71.2none
37 × 2.531.536.0C2 (M40)26.74.8D (M50), 37.7

Three things follow. On the smallest cables the choice is between two M20 sizes and costs nothing to get right. On three- and four-core power cable from 16 mm² upward the required reduction is frequently 2 mm or more; where the bedding is thinner than half that figure, the barrier gland lands one size, and one entry thread, above the compression gland that would have been chosen for the same cable, and the enclosure entry or an adaptor has to follow. And on rows marked "none", no larger size accepts the cable's nominal overall diameter, so the bundle is measured on the actual cable before the order is placed. Where a nominal diameter sits on the edge of a size's range, as 37 × 2.5 mm² does on size D, the actual cable decides. Other makers' dimensions differ; the cable in hand is measured in every case.

12. Compound, assembly and conversion

PropertyExPress barrier resin (standard supply)QSP two-part putty (suffix Q)
FormTwo-part epoxy in a cartridge with a mixing nozzle, mixed 1:1 by volume as it is dispensedTwo-part hand-mixed epoxy putty, mixed 1:1 until one uniform colour
Before fillingPurge a bead of about 25 mm onto a disposable surface so that what enters the pot is fully mixedKeep at 20 °C or above before use; do not mix or install below 5 °C
FillingGland held vertical; fill from the bottom of the pot to about 3 mm below flush, the fill line on the potPack between the spread cores, close the cores, pack around them, slide the pot over
InspectionNo voids; move the cores and work out air through the pot; top up to the fill line if the level dropsInspect for voids through the transparent pot and repair before cure
Working time30-minute gel time (specification sheet)Use within 30 minutes of mixing
Cable without inner sheath, or poorly filledTape the base of the cores to form a sealing surface; pack large voids with non-conductive putty or waddingThe resin dam is removed when putty is used
After fillingPlace the entry over the pot to hold its shape while the resin gels; cores are manipulated and the circuit energised only when the resin has fully curedThe same
InstructionAI 2035AI 2034

The resin's data sheet gives 14, 24 and 50 ml cartridges, a cured hardness of 75 to 85 Shore D and a shelf life of 24 months unopened. Gloves supplied with the kit are worn throughout. Cure time depends on temperature and is read from Hawke's cure graphs.

Assembly, in outline (AI 2001, Issue H): slide the backnut, middlenut and armour clamp ring onto the cable; fit the spigot and push the armour to its shoulder; clamp the armour by tightening the middlenut to the entry hand tight plus ½ to ¾ turn, then open and inspect the clamp; strip the inner sheath to between flush and 3 mm from the spigot end so that it protrudes through the resin dam; fit the pot and fill it; fit the entry to the enclosure, seat the pot, and tighten the middlenut hand tight plus ⅕ to ¼ turn; tighten the backnut until it seals on the cable, then one further full turn; check the backnut position against the tightening guide. The complete step tables, strip lengths and clamp-ring orientations are in the Hawke 501/453 and ICG 653 installation and inspection guide. On unarmoured cable (AI 2040) the same parts are used; the clamp ring's orientation is unimportant and it sits between the spigot and the middlenut.

Converting an installed gland. A 501/453/UNIV whose body is dual-marked "HAWKE 501/453 UNIV (BLACK) / HAWKE ICG 653 UNIV (RED)" can be converted to an ICG 653/UNIV with Hawke's barrier upgrade kit (AI 2037), reusing the entry, middlenut, backnut and armour clamp ring. The kit supplies the compound pot and spigot, a red deluge boot and the compound. For a site moving from one rule set to another, or correcting entries found non-compliant at inspection, this turns a cable re-termination into a kit per entry instead of a new gland per entry. Conversion kits in the cballast catalogue: size Os, size O, size A, size B.

13. Inspection and records

The 2024 edition gives initial inspection its own clause (clause 9) and an informative annex of inspection tables aligned with IEC 60079-17, which continues to govern periodic inspection. For a flameproof cable entry the checks reduce to the following.

CheckWhat is looked for
Entry type against the rule appliedThe gland schedule states the rule set (edition, national annex, operator specification) and the entry type it produced for each enclosure
IdentityMarking Ex db IIC Gb on the gland; certificate number ending in X, so the schedule of limitations has been read; red deluge boot on an ICG 653/UNIV
CompoundPot filled to the line, no voids, cores central; inspected through the transparent pot at assembly and whenever the entry is opened at a detailed inspection
LimitsCore count and bundle diameter within the size's limits; compound cross-section at least 20% of the area over 20 mm depth
MechanicalArmour clamped; backnut position on the tightening guide; entry perpendicular to the enclosure face; thread engagement to IEC 60079-1
IngressCertified sealing washer or other approved method on a smooth, undamaged face; thread sealant where the IP68 depth rating is relied on; sealed entry thread in increased-safety use
Cable evidenceWhere a compression gland was accepted under the 2024 flowchart, the Annex C test report for the cable type is in the file
Cable lengthConnected length recorded where the 3 m or 0.5 m test was relied on

The record that makes these checks quick is a gland schedule with one row per entry: enclosure tag, gas group, zone, volume, internal ignition source yes or no, cable type, connected length, Annex C evidence yes or no, rule applied, entry type, gland identifier, compound batch and installation date.

14. Article numbers: ICG 653/UNIV and the compression alternative

Hawke ICG 653/UNIV barrier glands in the cballast catalogue, by size and body material. Each number is the Nordic trade article number and links to the product page.

SizeEntry threadBrassNickel-plated brass316 stainless steel
OsM20125327012328121232821
OM20125327112328111232820
AM20on request12328041232813
BM25125327312328051232814
CM32125327412328061232815
C2M4012532751232807on request
DM50125327612328081232817
EM63125327712328091232818
FM7512532781232810on request

The compression alternative on the same body, the 501/453/UNIV, for the entries where the rule applied permits it:

SizeEntry threadBrassNickel-plated brass316 stainless steel
OsM2012535391232844on request
OM20125354012328431253810
AM20125354112328331253811
BM25125354212328341253812
CM32125354312328351253813
C2M40125354412328361253814
DM5012535451232837on request
EM63125354612328381253816
FM7512535471232839on request

For unarmoured cable the compression gland is the 501/421 (for example size B, M25, brass). Entry accessories used with either gland: sealing washers (M20, M25), locknuts (M20, M25), earth tags (M20, M25), serrated washers (M20, M25) and thread adaptors such as the 476 M25 to M20. Every family, size and thread is tabulated in the Hawke cable glands sourcing index, and the full listing is on the Hawke brand page. Sizes and materials shown as "on request" are quoted against the same part string.

A schedule is quoted in one pass when it carries these lines:

BARRIER GLAND SCHEDULE
1  Rule set for entry selection: IEC 60079-14 edition, national annex, operator specification
2  Per enclosure: gas group, zone, volume, internal source of ignition (yes/no), entry thread
3  Per cable type: maker, standard, cores x mm2
4  Measured: overall diameter, diameter over inner sheath, diameter over cores, armour type and thickness
5  Connected cable length per entry
6  Annex C test report held for the cable type (yes/no)
7  Gland: Hawke ICG 653/UNIV, size, thread, material (brass, nickel-plated brass, 316L)
8  Compound: ExPress resin or QSP putty; number of spare compound kits
9  Per entry: sealing washer, locknut, earth tag, serrated washer, shroud, adaptor or reducer
10 Quantity per size, spares allowance, required date, delivery point
11 Documents: ATEX, IECEx and UKEX certificates, declaration of conformity, assembly instructions, origin

Schedules and single lines are quoted at sales@cballast.com.

Frequently asked questions

When is a barrier gland required on an Ex d enclosure?
It depends on the rule set in force. Under the selection chart used in IEC 60079-14 to 2007 and still applied in UK practice: when the enclosure contains an internal source of ignition and either the gas is IIC, or the enclosure is in Zone 1 and larger than 2 dm³. Under the 2013 edition: when the cable is not circular and compact with extruded bedding and non-hygroscopic fillers, or the connected cable is shorter than 3 m. Under the 2024 edition: when the cable is shorter than 3 m in IIC or IIB + H2 service or shorter than 0.5 m otherwise, and wherever the flowchart calls for Annex C test evidence that is not available.
What is the difference between a barrier gland and a standard flameproof gland?
A standard flameproof gland seals on the cable's inner sheath with an elastomeric ring, so the flame path through the cable depends on the cable's construction. A barrier gland fills the space around the individual cores with a compound that sets hard, so the path is closed at the gland whatever the cable's construction. Both are certified to IEC 60079-1 and marked Ex db.
What is the 2 litre rule for barrier glands?
It is the last question of the selection chart in IEC 60079-14 up to the 2007 edition: for an enclosure with an internal source of ignition in Zone 1 and a gas group below IIC, a barrier gland or sealing device is required if the enclosure volume exceeds 2 dm³. The chart remains in the National Annex of BS EN 60079-14:2014.
What is the 3 metre rule?
Clause 10.6.2(b) of IEC 60079-14:2013 allows a flameproof gland with a sealing ring only on a qualifying cable with at least 3 m of connected cable. Shorter tails need a barrier gland or another entry method. In the 2024 edition 3 m remains the minimum length for IIC and IIB + H2 service.
What changed for cable glands in IEC 60079-14:2024?
The selection of flameproof cable entry devices moved to a flowchart, Figure 2, which uses gas group, connected cable length (3 m, or 0.5 m for IIA and IIB), enclosure volume (2,000 cm³) and evidence that the cable has passed the pressure test in a new normative Annex C. Cables and entry devices for direct entry have their own clauses, 7.4.3 and 7.5.7.
What is the Annex C test?
A pressure test procedure for cables entering Ex d enclosures, normative in IEC 60079-14:2024. It exists only to help the user decide between a gland with an elastomeric seal and one that seals around the cores. It does not show that a cable is gas tight or flameproof. The evidence is a test report for the cable type, obtained from the cable maker.
Does the United Kingdom still use the selection chart?
BS EN 60079-14:2014 carries the chart in an informative National Annex, and HSE safety notice HID 1-2016 tells duty holders to apply it as relevant good practice. That edition is withdrawn on 4 October 2027. BS EN IEC 60079-14:2024, published on 31 August 2026, has its own National Annex NA, which is read together with the site standard.
Is a barrier gland required for hydrogen?
Under the chart, yes, wherever the flameproof enclosure contains an internal source of ignition, because hydrogen requires IIC equipment. Under the 2024 flowchart a barrier gland is required for IIC or IIB + H2 when the connected cable is shorter than 3 m, and whenever Annex C evidence for the cable is not available. Many hydrogen project specifications call for barrier glands on all flameproof entries.
Can a barrier gland be used on Ex e equipment?
Yes, where its marking covers it. The Hawke ICG 653/UNIV is marked Ex db IIC Gb, Ex eb IIC Gb, Ex nR IIC Gc and Ex tb IIIC Db. On increased-safety equipment it is typically chosen for cables with cold-flow characteristics, poorly filled cables and cables with fibre-optic cores; the entry thread is then sealed to maintain the enclosure's ingress rating.
How many cores can a Hawke ICG 653/UNIV take?
12 in sizes Os and O, 15 in A, 30 in B, 42 in C, 60 in C2, 80 in D, 100 in E and 120 in F, subject to the maximum diameter over cores for each size (8.0 to 59.8 mm). Fibre-optic limits are 48, 48, 72 and 144 for sizes Os to B.
Can an installed Hawke 501/453/UNIV be converted to a barrier gland?
Yes, if its body is dual-marked "HAWKE 501/453 UNIV (BLACK) / HAWKE ICG 653 UNIV (RED)". Hawke's upgrade kit replaces the diaphragm seal and spigot with a compound pot and spigot, a red deluge boot and compound, reusing the entry, middlenut, backnut and clamp ring. The cable is re-terminated to the ICG 653/UNIV instruction.
ExPress resin or QSP putty?
ExPress is the standard supply: an injectable two-part epoxy dispensed from a cartridge through a mixing nozzle into the transparent pot, with a 30-minute gel time. QSP is a hand-mixed putty packed around the cores, used within 30 minutes of mixing and not mixed or installed below 5 °C. Both are inspected through the pot before cure; in both cases the circuit is energised only after full cure.
Do existing installations have to be changed when the standard changes?
IEC 60079-14 governs design, selection, installation and initial inspection. What is done about entries installed under an earlier edition is decided by the operator's inspection regime under IEC 60079-17 and by the national regulator's guidance, as in the UK notice described above. Where an entry is to be changed, the conversion kit avoids replacing the gland on dual-marked bodies.
Where are Hawke ICG 653/UNIV barrier glands and conversion kits sourced?
cballast.com lists the ICG 653/UNIV in brass, nickel-plated brass and 316 stainless steel from size Os (M20) to size F (M75), with conversion kits for sizes Os to B and the washers, locknuts, earth tags and adaptors each entry consumes, and quotes complete gland schedules against the part strings. Requests go to sales@cballast.com.

16. Terms

17. Sources

IEC 60079-14, editions of 2007, 2013 and 2024 (published contents, clause titles and figures list). IEC SC 31J, supporting document SD 001:2022, *Background to flameproof cable gland requirements in IEC 60079-14*. Health and Safety Executive, safety notice HID 1-2016, *Use of Barrier Glands in Potentially Explosive Atmospheres to meet IEC 60079-14:2013 (Edition 5)*, 1 February 2016. BSI, BS EN 60079-14:2014 (National Annex) and BS EN IEC 60079-14:2024 (national and European forewords). M. Thedens, Chair of IEC TC 31, "Edition 6 of IEC 60079-14 is here!", Hazardex, November 2024. Element Materials Technology, *How IEC 60079-14:2024 redefines flameproof cable and cable gland selection*. IEEE PCIC paper 2018-PCIC-0385, *Cables and cable glands for hazardous locations*. Hawke International: specification sheet for the ICG 653/UNIV; assembly instructions AI 2001, AI 2034, AI 2035, AI 2037 and AI 2040; ExPress resin technical data sheet. Prysmian: datasheet for BFOU 0.6/1 kV to NEK TS 606. Standards referred to: IEC 60079-0, -1, -7, -15, -17 and -31; IEC 60529; IEC 62262; IEC 62444.

Related guides

*cballast.com is an industrial parts catalogue and planned-procurement sourcing house operated from Norway, listing more than 330,000 part numbers from more than 1,000 brands across 54 categories for operators, EPC contractors, shipyards, utilities and public institutions. Hawke requirements, from single lines to complete gland schedules, are handled at sales@cballast.com.*

Open / Download PDF

Compiled by cBallast for identification and cross-reference. Part numbers, designations and trademarks belong to their respective manufacturers. Confirm ratings and dimensions against the manufacturer's current documentation and the nameplate of the installed equipment before ordering or installation.