Hawke International — Product Range, Types & Certificates

Reference compiled by cBallast. 7-page PDF; the full content is on this page.
Brand
Hawke
Subject
Hazardous-area cable glands & fittings
Document type
Reference
Reference
2026 edition
Issued
2026-11-22
Pages
7
Format
Web page and PDF

The 2026 reference to Hawke International: every gland family from the 501/453 Universal to barrier, unarmoured and industrial types, the InstrumEx, ControlEx and PowerEx connectors, enclosures, breathers, adaptors and stopping plugs — with cable acceptance tables, the current ATEX, IECEx, UKEX, cCSAus and marine certificates, how identifiers and Ex markings read, and where each family is used by sector from offshore and marine to hydrogen and data centres.

Published by cballast.com. Last reviewed November 2026. Product data is taken from Hawke International's current specification sheets, assembly instructions and catalogue; certificate numbers are quoted as Hawke prints them. In brief. Hawke International is the British manufacturer whose cable glands, connectors and enclosures are specified across the offshore, marine, petrochemical and process industries for electrical installations in explosive atmospheres. Its best-known product, the 501/453 Universal cable gland, is one member of a range that runs from flameproof barrier glands to Ex connectors with sixty contacts. This reference maps the whole range: what each type number is, which cable and protection concept it serves, how the markings read, which certificates apply today, where each product family is used by sector, and how the range is identified and supplied.

1. Key facts

FactDetail
MakerHawke International, founded by William Hawke; the company dates the first Hawke cable gland to July 1957
OwnershipA Hubbell brand since 2002
Product familiesCable glands; connectors; enclosures; control stations; breathers; accessories (thread adaptors, reducers, stopping plugs, fittings)
Output"Hundreds of thousands" of cable glands every month, per the company
Flagship productThe Universal cable gland (501/453/UNIV), which Hawke describes as a market leader for some twenty years
Quality systemISO 9001
Certification schemesATEX, IECEx, UKEX, cCSAus, Inmetro, KCs, PESO, CCC, EAC, SONCAP; marine approvals ABS, BV and DNV on the principal gland families
Protection conceptsEx db (flameproof), Ex eb (increased safety), Ex nR (restricted breathing), Ex tb and Ex ta (dust)
Gas groupIIC on the principal families, which covers IIA and IIB
Zones1 and 2 (gas), 21 and 22 (dust); 20 on the A2E
Ingress and impactIP66, IP67, IP68 (30 m for 7 days), IP69 on the Universal; IK10; deluge-tested to Hawke's DTS01
MaterialsBrass, nickel-plated brass, 316L stainless steel; aluminium on some types; glass-reinforced polyester and stainless steel for enclosures
SizesGland size letters Os, O, A, B, C, C2, D, E, F, G, H, J (M16 to M100; ½" to 4" NPT)

2. The range at a glance

FamilySeriesWhat it is
Cable glands, armoured cable501/453/UNIV, 501/453/RAC, 501/453/RAC/LEx d / Ex e glands with a reversible armour clamp for wire armour, braid and tape
Cable glands, barrierICG 653/UNIV, ICG 653/UNIV/L, ICG 623, PSG 553/RAC, SB 474, CSB 656NGlands that seal around the individual cores with a compound or a punched seal
Cable glands, unarmoured cable501/421, 501/421/R, 501/423, 501/414, 321, A2EEx d / Ex e and Ex e-only glands sealing on the outer sheath
Cable glands, North American711Barrier gland for MC-HL metal-clad cable, UL listed
Cable glands, industrial151/RAC and related typesSafe-area glands on the same size letters
ConnectorsInstrumEx, ControlEx, PowerExEx plug-and-socket connectors for instrument, control and power circuits
EnclosuresPL range, EA range, S-SeriesEx e junction and terminal boxes in glass-reinforced polyester and stainless steel
Control stationsBuilt on the enclosure rangesEx push-button, selector and indicator stations
Breathers and drains389, 489Ex e and Ex d breather drains
Thread adaptors and reducers476Ex d / Ex e thread conversion between metric and NPT sizes
Stopping plugs487, 475, 390, 375, 387Certified closures for unused entries
FittingsLocknuts, earth tags, serrated washers, sealing washers, shrouds, GMC clamps, barrier upgrade kitsThe parts that complete an entry

3. Cable glands for armoured cable

TypeCableSeal on the cableTemperatureCertificates (ATEX / IECEx / UKEX)Notes
501/453/UNIVWire armour W, wire braid X, steel tape Z; elastomer and plastic insulated; cold-flow cablesPatented diaphragm seal on the inner sheath; rear seal and inspectable deluge seal on the outer sheath−60 to +80 °CCML 18ATEX1268X / CML 18.0131X / CML 21UKEX1132XHawke's Universal; IP66/67/68/69; IK10; tightening guide on the middlenut; black deluge boot
501/453/RACW, X, ZElastomeric compression seal on the inner sheath; outer seal−60 to +100 °CCML 19ATEX1167X / CML 19.0045X / CML 21UKEX1161XSizes to J (M100); alternative clamp ring option
501/453/RAC/LLead-sheathed armoured cableSeal and electrical bond to the lead inner sheathAs RACAs RACOrdered with L or K suffix
ICG 653/UNIVW, X, Z; cables not effectively filled, with hygroscopic fillers, cold-flow characteristics or fibre-optic coresTwo-part compound barrier around the cores in a transparent, inspectable pot−60 to +80 °CCML 18ATEX1268X / CML 18.0131X / CML 21UKEX1132XExPress liquid resin as standard; QSP hand-mixed putty by adding Q; red deluge boot; cCSAus 1024328
ICG 653/UNIV/LLead-sheathed armoured cableCompound barrier plus seal and bond to the lead sheathAs ICG 653As ICG 653—
PSG 553/RACArmoured cablePunched-seal barrier with armour clampingPer Hawke's sheetPer Hawke's sheetBarrier without poured compound; RAC ring option

All of these carry the marking Ex db IIC Gb, Ex eb IIC Gb, Ex nR IIC Gc and Ex tb IIIC Db, with Ex nR under CML 19ATEX4507X, IECEx CML 21.0012X and CML 21UKEX4133X. Construction and testing are to IEC/EN 60079-0, -1, -7, -15 and -31 and to IEC/EN 62444 (anchorage type D on the ICG 653/UNIV). The 501/453/UNIV and the 501/453/RAC seal on the cable's sheath and are not barrier glands; the ICG 653/UNIV is the barrier gland on the same body, and dual-marked 501/453/UNIV glands can be converted to it with Hawke's barrier upgrade kit.

Cable acceptance of the 501/453/UNIV, the row every other armoured type is read against:

SizeThreadInner sheath (mm)Outer sheath (mm)Armour, thick / thin orientation (mm)
OsM203.5–8.15.5–12.00.8–1.25 / 0–0.8
OM206.5–11.49.5–16.00.8–1.25 / 0–0.8
AM208.4–14.312.5–20.50.8–1.25 / 0–0.8
BM2511.1–19.716.9–26.01.25–1.6 / 0–0.7
CM3217.6–26.522.0–33.01.6–2.0 / 0–0.7
C2M4023.1–32.528.0–41.01.6–2.0 / 0–0.7
DM5028.9–44.436.0–52.61.8–2.5 / 0–1.0
EM6339.9–56.346.0–65.31.8–2.5 / 0–1.0
FM7550.5–68.257.0–78.01.8–2.5 / 0–1.0

The ICG 653/UNIV adds a core-count limit per size: 12 cores at Os and O, 15 at A, 30 at B, 42 at C, 60 at C2, 80 at D, 100 at E and 120 at F (48, 48, 72 and 144 fibre-optic cores at Os, O, A and B).

4. Cable glands for unarmoured cable

TypeProtectionSealTemperatureCertificates (ATEX / IECEx / UKEX)Use
501/421Ex db, Ex eb, Ex nR, Ex tbElastomeric seal on the outer sheath; alternative seal S−60 to +100 °CCML 19ATEX1167X / CML 19.0045X / CML 21UKEX1161XThe standard dual-certified gland for unarmoured elastomer and plastic cables; braided cable where braid and sheath pass into the enclosure
501/421/RAs 501/421Outer-sheath seal plus cable clampAs 501/421As 501/421Where the cable must be restrained at the gland
501/423Ex db, Ex eb, Ex nR, Ex tbDouble elastomeric compression seal on the outer sheath−60 to +100 °CCML 19ATEX1167X / CML 19.0045X / CML 21UKEX1161XGroup II double-seal gland; better cable retention than single-seal types
501/414Ex db, Ex eb, Ex nR, Ex tbOuter-sheath seal; female threaded running coupler−60 to +100 °CCML 19ATEX1167X / CML 19.0045X / CML 21UKEX1161XUnarmoured cable installed in conduit; IP66/67
ICG 623Ex d / Ex e barrierCompound around the individual cores; QSP putty versionPer Hawke's sheetPer Hawke's sheetBarrier gland for unarmoured cable
SB 474Ex d / Ex e barrierSeal with core holes punched to suit, using Hawke punch tools 1 to 3Per Hawke's sheetPer Hawke's sheetBarrier without poured compound
CSB 656NEx d / Ex e barrierCompound around individual conductors; male and female threadsPer Hawke's sheetPer Hawke's sheetConductors in conduit
321Ex eb IIC Gb, Ex tb IIIC DbElastomeric Ex e seal on the outer sheath; alternative seal S−60 to +100 °CCML 19ATEX3164X / CML 19.0042XIncreased-safety and dust enclosures only
A2E (APEX A2e)Ex eb IIC Gb, Ex nR IIC Gc, Ex ta IIIC DaIP washer, inner seal, skid washer−60 to +130 °CCML23ATEX1002X / CML 23.0001X / CML23UKEX1004XEx e gland with the widest temperature range; dust to Zone 20; IP66/67

Cable acceptance of the 501/421 (per the current specification sheet; the 501/423 and 321 follow the same compression-seal table):

SizeThreadStandard seal, outer sheath (mm)Alternative seal S (mm)Across flats (mm)
2KM163.2–8.0—19.0
OsM20 (M16 available)3.2–8.0—24.0
OM20 (M16 available)6.5–11.9—24.0
AM2010.0–14.39.0–13.430.0
BM2513.0–20.29.5–15.436.0
CM3219.5–26.515.5–21.246.0
C2M4025.0–32.522.0–28.055.0
DM5031.5–44.427.5–34.865.0
EM6342.5–56.339.0–46.580.0
FM7554.5–68.249.5–58.395.0
GM8067.0–73.0—106.4
HM9067.0–77.6—115.0
JM10077.0–91.6—127.0

The 501/421, 501/423 and 501/414 are built and tested to IEC/EN 62444 (anchorage type B) as well as the IEC 60079 series, are rated IK10 and carry cCSAus 1015065. For Ex d use the cable must meet the requirements of IEC 60079-14, and glands for unarmoured and braided cable are for fixed installations with the cable secured against pull and twist. The 321 and A2E carry no flameproof marking and are not fitted to Ex d enclosures.

5. Other gland families

TypeWhat it isKey data
711Barrier gland for North American MC-HL (corrugated metal-clad) cableUL listed (E84940) with ATEX and IECEx certification (Sira 06ATEX1295X; IECEx SIR 06.0082X); −60 to +80 °C (ATEX), −50 to +60 °C (UL)
653/UNIV mining glandGroup I version of the Universal barrier body for miningPer Hawke's mining specification sheet
151/RACIndustrial gland for armoured cable (wire W, braid X, aluminium strip Y, steel tape Z) in safe areasEN 50262; BS 6121 Part 1 types CW, CX, CY, CZ; IP66; −60 to +100 °C; not Ex certified

6. Connectors

Hawke's connectors allow equipment in hazardous areas to be connected and disconnected without opening an enclosure or re-making a gland, which is why they appear on skids, portable equipment, drilling packages and anything that is replaced as a unit.

RangeDutyProtection and markingRatingsCertificatesFeatures
InstrumExInstrument and signal circuitsEx de IIC, dust Ex tD (II 2 GD), per Hawke's catalogueIP66/67; DTS01 deluge; −40 to +60 °CBaseefa06ATEX0061X; IECEx BAS 06.0018XBulkhead receptacle, connector plug and inline receptacle forms; crimped or soldered contacts; secondary keying; four-start ACME thread; reversible armour clamp; anti-rotation spigot
ControlExControl and low to medium powerEx db IIC Gb T5/T6; Ex tb IIIC Db T95/T80; Class I Zone 1 AEx d IICUp to 60 contacts; up to 125 A and 750 V depending on contact arrangement; conductors 0.5 to 35 mm²; 316L stainless steel; IP66/67; DTS01; −40 to +60 °CBaseefa12ATEX0014X; IECEx BAS 12.0006X; BAS21UKEX0067X; cCSAus 2633583; ABS, BV, DNVFront and back pin and socket inserts; keying against misconnection; optional locking pin; running coupler for fitting to a pre-assembled gland; ACME thread; inspectable flameproof barrier
PowerExPower circuitsEx d IIC, dust Ex tD (II 2 GD), per Hawke's catalogueIP66/67; DTS01; −40 to +60 °CBaseefa06ATEX0062X; IECEx BAS 06.0019XField-wireable; internal earth as standard; five-position insert keying; running coupler; ACME thread

Zones: 1, 21, 2 and 22. Standards on the ControlEx certificate: IEC/EN 60079-0, -1 and -31, CSA/UL 60079-0, -1 and -31 and UL 1977.

7. Enclosures, control stations and breathers

RangeMaterialCharacterUse
PL rangeGlass-reinforced polyesterEx e; impact strength quoted to 20 Nm; resistant to corrosive atmospheresJunction and terminal boxes for instrumentation and power
EA range—Ex e; sloped-face design for fast installation and inspection; dust-tight and watertightTerminal boxes where access matters
S-SeriesStainless steelThe most robust range; chemical corrosion resistance; Zones 1, 2, 21 and 22Offshore, marine and chemical plant
Control stationsBuilt on the enclosure rangesATEX, IECEx and ULLocal start/stop, selector and indication
389 breather drainBrass, nickel-plated brassEx eCondensation drain and pressure equalisation on Ex e enclosures
489 breather drainBrass, nickel-plated brassEx dThe same on flameproof enclosures

Hawke states more than thirty years of enclosure manufacture and names oil and gas, offshore wind and petrochemical among the applications.

8. Adaptors, plugs and fittings

TypeFunctionProtectionNotes
476Thread adaptor (smaller male to larger female) and reducer (larger male to smaller female)Ex d / Ex eMetric to metric, NPT to metric, NPT to NPT; Hawke's part string marks them 476/A and 476/R
487Dome-head stopping plugEx d / Ex eFor unused entries on either enclosure type
475Tamperproof stopping plugEx dRemovable only with a tool
390Hex-head stopping plugEx eNot for flameproof enclosures
375Nylon stopping plugEx eNot for flameproof enclosures
LocknutSecures a gland in a clearance hole—By thread and material
Earth tagExternal bonding point for the armour—By thread
Serrated washerResists loosening of the locknut under vibration—Stainless steel
Sealing washerMaintains the enclosure's IP rating at the entry—Required on Ex e entries by the glands' conditions of use
ShroudAdditional corrosion protection—By gland size
GMCGland-mounted clamp restraining unarmoured cable—Terminal sizes 1 to 5
Barrier upgrade kitConverts a dual-marked 501/453/UNIV to an ICG 653/UNIV—Compound pot and spigot, red deluge boot, compound

9. Reading a Hawke identifier and marking

Ordering designation. Type, size, thread, material, suffix: 501/453/UNIV C M32 NP AR is a Universal gland, size C, M32 entry, nickel-plated brass, with the alternative armour clamp ring. Brass is implied when no material is stated. S denotes the alternative seal on compression-seal glands; Q denotes quick-set putty on barrier glands; NPT threads are written as decimals in Hawke's part strings (1.25 for 1¼").

Part strings. 453UCM32R is the same Universal gland in Hawke's compressed form (type 453U, size C, M32, R for the alternative ring); 653U C 1.25 NP R Q is an ICG 653/UNIV, size C, 1¼" NPT, nickel-plated, alternative ring, putty compound.

Body marking. Each gland carries its type, size and certificate marking; dual-marked Universal bodies read "HAWKE 501/453 UNIV (BLACK) / HAWKE ICG 653 UNIV (RED)", the colour being that of the deluge boot fitted.

Ex marking, read left to right.

ElementMeaning
II 2 GDATEX equipment group II (surface industries), category 2, gas and dust
Ex dbFlameproof enclosure, equipment protection level b
Ex ebIncreased safety, level b
Ex nRRestricted breathing (Zone 2)
Ex tb / Ex taDust protection by enclosure, level b (Zones 21, 22) or a (Zone 20)
IICGas group including hydrogen and acetylene; covers IIA and IIB
IIICConductive dust; covers IIIA and IIIB
Gb / Gc / Db / DaEquipment protection level for gas (Zone 1 / Zone 2) and dust (Zone 21 / Zone 20)
X after the certificate numberSpecial conditions of use apply, printed in the assembly instruction

10. Where the range is used, by sector

SectorTypical hazardous areasGoverning documentsHawke families that apply
Offshore oil and gasProcess, wellhead and drilling areas; deluge-protected modulesIEC 61892-7; IEC 60079-14 and -17; NORSOK E-001 on the Norwegian shelf; operator specifications501/453/UNIV and RAC on braided NEK TS 606 and wire-armoured cable; ICG 653/UNIV where a barrier is required; S-Series enclosures; connectors on skids and drilling packages
Marine and shipbuildingTanker cargo areas, paint and battery stores, fuel-gas spacesIEC 60092-502; classification society rules501/453 families with ABS, BV and DNV approval on shipboard cable to IEC 60092-353; 151/RAC outside hazardous zones
Refining, petrochemical and chemicalProcess units, tank farms, loading baysIEC 60079-10-1 for classification; IEC 60079-14 and -17; ATEX 1999/92/EC and its national implementationsWhole range; 711 on North American projects
Hydrogen and power-to-XElectrolyser halls, compression, storage and dispensingIEC 60079-10-1; group IIC equipmentAll principal Hawke families are certified IIC; barrier glands where the installation standard requires them
Data centresBattery rooms (hydrogen evolved on charge; ventilation to EN IEC 62485-2), hydrogen and gas fuel systems for on-site generation, fuel-handling plantEN IEC 62485-2; IEC 60079-10-1Ex families in the classified rooms; 151/RAC on armoured power cable in plant rooms outside them
AviationFuel farms and hydrant systems for Jet A-1; aircraft hangarsIn the United States NEC Article 513 classifies hangar pits as Class I Division 1 and the floor area to 18 inches, and the space within 5 feet of aircraft power plants and fuel tanks, as Division 2; in Europe classification follows 1999/92/EC and IEC 60079-10-1Ex d / Ex e glands and enclosures in classified areas; cCSAus-certified types for North American installations
MiningUnderground workings (Group I)IEC 60079-0 Group I653/UNIV mining gland
Offshore wind and renewablesSubstations, transformer and battery spacesProject specificationsEnclosures and glands; Hawke names offshore wind among its enclosure applications

Classification of any real area is the work of the installation's designer under the applicable standard; the table shows where classified areas arise, not their extent.

11. Certificates in force

ProductATEXIECExUKEXNorth AmericaMarine and other
501/453/UNIVCML 18ATEX1268XCML 18.0131XCML 21UKEX1132XcCSAus 1015065Inmetro IEx 14.0272X; PESO P450038; EAC; KCs; CNEx
ICG 653/UNIVCML 18ATEX1268XCML 18.0131XCML 21UKEX1132XcCSAus 1024328ABS 19-LD1876514-1-PDA; BV 43523/B0; DNV TAE0000BS; CCC; EAC; Inmetro; KCs; PESO; SONCAP
501/453/RACCML 19ATEX1167XCML 19.0045XCML 21UKEX1161XcCSAus 1015065DNV TAE0000BS; Inmetro IEx 14.0272X; EAC
501/421, 501/423, 501/414CML 19ATEX1167XCML 19.0045XCML 21UKEX1161XcCSAus 1015065ABS 19-LD1876514-1-PDA; BV 43523/B0; DNV TAE0000BS (501/421); CCC; EAC; Inmetro; PESO
Ex nR on the aboveCML 19ATEX4507XCML 21.0012XCML 21UKEX4133X——
321CML 19ATEX3164XCML 19.0042X———
A2ECML23ATEX1002XCML 23.0001XCML23UKEX1004X——
ControlExBaseefa12ATEX0014XBAS 12.0006XBAS21UKEX0067XcCSAus 2633583ABS, BV, DNV, EAC, Inmetro, PESO, SONCAP
InstrumExBaseefa06ATEX0061XBAS 06.0018X———
PowerExBaseefa06ATEX0062XBAS 06.0019X———

Glands installed before the current certificates were issued carry Baseefa numbers for the same products (Baseefa06ATEX0057X on the Universal, 0056X on the 501/421 family, 0058X on the ICG 653); a current replacement of the same type and size is the same product under its current certificate, and an asset register should record both.

12. The Hawke range at cballast

cballast lists 335 Hawke variants, each under its Hawke designation and its Nordic trade article number, with the cable range, thread, material and certificates on the page.

FamilyListed variantsExample
501/453/UNIV27Size B, M25, nickel-plated brass
501/453/RAC9Size B, M25, nickel-plated brass
ICG 653/UNIV24Size B, M25, nickel-plated brass
501/42122Size B, M25, brass
501/42318Size B, M25, nickel-plated brass
3212Size Os, M20, nickel-plated brass
A2E20Size B, M25, nickel-plated brass
151/RAC9Size C, M32, brass
476 adaptors and reducers80M25 to M20, brass
487 stopping plugs22M20, nickel-plated brass
475 stopping plugs11M20, brass
390 stopping plugs16M20, nickel-plated brass
375 and 387 stopping plugs7375, M20, nylon
389 and 489 breather drains8389, M20, brass
Locknuts20M20, brass
Earth tags16M20, brass
Serrated washers8M20, 316 stainless steel
Sealing washers7M20
GMC clamps5Terminal size 3, for size A
Barrier upgrade (conversion) kits4Size B

The full line is on the Hawke brand page. Variants Hawke makes that are not carried as listed lines (other materials and NPT threads, sizes G to J, lead-sheath and punched-seal types, connectors and enclosures) are supplied against the same designations.

Supply. cballast supplies Hawke to operators, EPC contractors, shipyards, panel builders and public institutions on account: single replacement lines, complete gland schedules for projects, and standing lists on agreed unit rates for operating assets. Every line is quoted on its Hawke designation and trade article number with a firm delivery date; declarations of conformity, ATEX, IECEx and UKEX certificates, assembly instructions, marine approvals and EN 10204 material certificates accompany the goods as specified; public bodies are invoiced by Peppol BIS or EHF. Requirements go to sales@cballast.com.

Frequently asked questions

What is Hawke International?
A British manufacturer of cable glands, Ex connectors, enclosures, control stations and fittings for electrical installations in hazardous areas and harsh environments, founded by William Hawke, producing glands since 1957 and part of Hubbell since 2002.
What does Hawke make besides cable glands?
Ex connectors (InstrumEx for instruments, ControlEx for control and power up to 60 contacts, 125 A and 750 V, PowerEx for power), Ex e enclosures in glass-reinforced polyester and stainless steel (PL range, EA range, S-Series), control stations, breather drains (389 and 489), thread adaptors and reducers (476) and stopping plugs (487, 475, 390, 375).
Which Hawke gland is used for armoured cable in Zone 1?
The 501/453/UNIV or the 501/453/RAC, both marked Ex db IIC Gb and Ex eb IIC Gb, for wire armour, braid and tape; the ICG 653/UNIV where the installation standard requires a barrier gland.
Which Hawke gland is used for unarmoured cable?
The 501/421 (single seal) or 501/423 (double seal) on Ex d and Ex e enclosures; the 321 or A2E on Ex e and dust enclosures only.
Are Hawke glands ATEX and IECEx certified?
Yes. The principal families carry ATEX, IECEx and UKEX certificates issued by CML (for example CML 18ATEX1268X and IECEx CML 18.0131X on the 501/453/UNIV and ICG 653/UNIV; CML 19ATEX1167X and IECEx CML 19.0045X on the 501/453/RAC, 501/421, 501/423 and 501/414), with cCSAus, marine and national-scheme approvals.
Are Hawke glands suitable for hydrogen?
The principal families are certified for gas group IIC, which includes hydrogen. The gland type at a flameproof entry in hydrogen service is decided by the installation designer under IEC 60079-14, which may require a barrier gland.
What do the Hawke size letters correspond to?
Thread sizes: Os, O and A are M20; B is M25; C is M32; C2 is M40; D is M50; E is M63; F is M75; G is M80; H is M90; J is M100; 2K is the M16 size of the 501/421 and 321. The letter is chosen from the cable's diameters, the thread from the enclosure.
Where can Hawke products be sourced with certificates and firm delivery dates?
cballast.com lists 335 Hawke variants by Hawke designation and Nordic trade article number and supplies the wider range against the same designations, with certificates and documents per line, to operators, contractors, yards and public institutions on account.

14. Sources

Hawke International: company information; specification sheets for the 501/453/UNIV, 501/453/RAC, ICG 653/UNIV, 501/421, 501/423, 501/414, 321 and A2E; assembly instructions AI 2000, AI 302, AI 2001, AI 2034 and AI 2037; gland, connector and enclosure catalogues. Standards and regulations: IEC 60079-0, -1, -7, -10-1, -14, -15, -17 and -31; IEC 62444; IEC 60529; IEC 62262; IEC 61892-7; IEC 60092-353 and -502; EN IEC 62485-2; NEC Article 513; Directives 2014/34/EU and 1999/92/EC; NEK TS 606; NORSOK E-001.

Related guides

cballast.com is an independent industrial and marine MRO distributor headquartered in Norway, supplying more than 336,000 part numbers from more than 1,000 brands to operators, EPC contractors, shipyards, utilities and public institutions.

Open / Download PDF

Compiled by cBallast for identification and cross-reference. Part numbers, designations and trademarks belong to their respective manufacturers. Confirm ratings and dimensions against the manufacturer's current documentation and the nameplate of the installed equipment before ordering or installation.