Marine Cable Types — RFOU, BFOU and IEC 60092 Selection

Selection guide compiled by cBallast. 9-page PDF; the full content is on this page.
Compiled by
cBallast
Subject
Marine and offshore shipboard cables
Document type
Selection guide
Reference
2026 edition
Issued
2026-11-09
Pages
9
Format
Web page and PDF

What RFOU, BFOU, RFCU and the other NEK 606 / IEC 60092 shipboard cable designations mean, the fire tests behind them (IEC 60332-3, IEC 60331, IEC 60754, IEC 61034), power against instrumentation constructions, voltage grades 250 V to 1 kV and above, screening and armour, mud resistance, class approvals, and a selection table by location on board — with the Prysmian and Nexans types held against it.

The short version

1. The IEC 60092 series, NEK 606 and what a designation encodes

IEC 60092 is the umbrella for electrical installations in ships; the cable parts that matter to a buyer are 60092-350 (general construction and test methods), 60092-351 (insulating compounds), 60092-353 (power cables, rated 0.6/1 kV and 1.8/3 kV), 60092-354 (higher voltages), 60092-376 (control and instrumentation circuits, 150/250 V) and 60092-352 (selection and installation). NEK 606 is the Norwegian offshore specification layered on top of the IEC constructions: it fixes the type letters, the colour (RFOU is typically black for power, grey or blue for instrumentation; blue marks intrinsically safe circuits), and the mud-resistance tests for drilling areas.

Letter blockReads asMeaning
R / BFlame-retardant / fire-resistantR = passes bunched-cable flame test IEC 60332-3-22 cat. A; B = additionally keeps circuit integrity in fire to IEC 60331 (mica-taped conductors)
FHalogen-freeSheath and insulation per IEC 60754-1/-2, low smoke per IEC 61034
OOil-resistant sheathSHF2-type halogen-free compound, tested for oil and mud exposure (NEK 606 mud resistance where marked)
UUnarmoured — braid onlyCopper or galvanised-steel wire braid for mechanical protection and screening; "C" in place of U denotes copper-braid collective screen constructions
(i) / (c)Individual / collective screenOn instrumentation pairs: each pair screened, or one overall screen

So RFOU 0.6/1 kV is the standard halogen-free, flame-retardant, oil-and-mud-resistant braided power cable of the Norwegian shelf; BFOU is the same construction with fire-resistant circuit integrity; RFOU(i) 250 V is its instrumentation sibling with individually screened pairs. Continental yards often buy the same constructions under maker names (Prysmian Bergen types, Nexans MPRX/SFOU families, Helkama, Draka marine); the designation on the class certificate is what carries.

2. The fire tests, decoded

TestStandardWhat passesWhat it proves
Single-cable flameIEC 60332-1-2A single vertical cable self-extinguishesMinimum for any fixed wiring
Bunched flame, cat. AIEC 60332-3-227 L/m of bunched cable does not propagate fire up a ladderThe "flame-retardant" in RFOU; mandatory for shipboard runs
Circuit integrityIEC 60331-21Cable keeps conducting through 90 min at 750 °C flameThe "fire-resistant" in BFOU; emergency consumers
Halogen acid gasIEC 60754-1/-2< 0.5% HCl equivalent; conductivity/pH limitsNo corrosive, toxic combustion gases in enclosed spaces
Smoke densityIEC 61034-2≥ 60% light transmittance in the 3 m cubeEscape routes stay visible

A cable marketed as "marine" that only cites IEC 60332-1 has passed the weakest test on the list. For bunched runs on cable ladders — which is every main run on a vessel — the bunched category A test is the one that matters, and the class type approval confirms it was run on the construction you are buying, not on a cousin.

3. Power, control and instrumentation constructions

DutyTypical constructionVoltage gradeGoverning partCatalogue example
LV power, motors, distributionRFOU or BFOU, 2–4 cores + earth, EPR/SHF2, braid0.6/1 kVIEC 60092-353Prysmian RFOU 1 kV 4x25/16 mm², RFOU 1 kV 4x50/25 mm²
Emergency consumers in fire zonesBFOU power cores, mica-taped0.6/1 kVIEC 60092-353 + IEC 60331Prysmian BFOU 1 kV 1x300/16 mm² mud-resistant
Analogue instrument loops, 4–20 mARFOU(i) or BFOU(i), individually screened pairs 0.75 mm²150/250 VIEC 60092-376Prysmian RFOU(i) 250 V 1x2x0.75
Multi-pair instrument trunksRFOU(c)/BFOU(c) 8–24 pairs, collective or pair screens150/250 VIEC 60092-376RFOU(c) 8 pair 0.75 mm², BFOU(c) 16 pair
Communication, PA/GA, telephoneScreened pairs/triples, often BFOU(c) for GA circuits150/250 VIEC 60092-376RFOU(c) 2 triple 0.75 mm²
Accommodation and light duty onshore-style runsHalogen-free installation cable where class accepts it300/500 VYard specificationNexans PFXP 500 V 3G1.5

Conductor sizes follow the same IEC 60228 class 2 (stranded) and class 5 (flexible) conductors as land cables; current-carrying capacity on board is taken from the tables of IEC 60092-352 with correction for 45 °C ambient in machinery spaces — a land rating to IEC 60364 overstates a marine rating, which is why the same 25 mm² cable carries less in an engine room than in a building. Our cable sizing guide covers the land tables and the derating logic; the AWG to mm² chart translates American drawings.

4. Screens, armour and earthing on board

The braid on an RFOU/BFOU cable is doing three jobs: mechanical protection, the earthed metallic covering that shipboard rules require for fixed cables in most locations, and — on instrumentation types — the EMC screen. Practice that keeps surveys quiet: braid earthed at both ends for power cables (through EMC or barrier glands into the gland plate), instrument pair screens earthed at one end only (the cabinet end) to avoid circulating currents, and intrinsically safe circuits on blue cable with their screens earthed at the barrier earth. Glands must match both the cable construction and the location — see the cable gland selection guide and the M12–M63 size chart; transits through fire divisions are their own discipline (Roxtec transit selection).

5. Choosing by location: a working table

Location / circuitCable classNotes
Engine room power and lightingRFOU 0.6/1 kV45 °C ambient derating; oil-resistant sheath is the point of the O
Fire pump, emergency switchboard feeders, steering gearBFOU 0.6/1 kVCircuit integrity consumers per SOLAS II-1 and class rules
PA/GA, emergency lighting, watertight doorsBFOU(c) / BFOUMust survive the fire they announce
4–20 mA field loops, machinery alarmsRFOU(i) 250 VIndividual screens; one-end earthing
Drill floor, mud areas (offshore)RFOU/BFOU with NEK 606 mud resistanceDrilling-fluid exposure tested; standard RFOU types from the Norwegian makers carry it
Hazardous areas (tankers, drilling)Same constructions + Ex glanding/IS rulesBlue sheath for IS circuits; entity and earthing rules in our ATEX/IECEx guide
Accommodation, dry spacesRFOU light constructions or accepted halogen-free installation cableYard standard governs

6. Buying marine cable sensibly

Cable is sold by the metre but priced by the drum, the cut and the certificate. What a requisition should carry: the designation and voltage grade (RFOU(i) 250 V, BFOU 0.6/1 kV), cores or pairs and cross-section (4x25/16 mm² reads four 25 mm² cores with a 16 mm² earth), the standard set (NEK 606, IEC 60092-353/-376), required class approval and society, outer diameter if glands and transits are already fixed, length per cut with a sensible margin, and whether the run is a fire-integrity consumer. Cut lengths from stock drums cost more per metre than full drums — on a 2,000 m order the difference funds the spare drum. Our note on package lengths explains why quotes come back in drum lengths, and the installation cable finder covers the land-side types often ordered alongside.

How buying works at cballast. We quote marine cable by designation, cross-section and length against the class certificate the vessel's society requires, from Prysmian, Nexans and the other approved makers' programmes, with glands, lugs (lug cross-reference) and transits in the same quote where the requisition implies them. Every new account is vetted at onboarding; the first order is prepaid; established accounts move to credit terms and repeat-account discounts; public bodies and utilities are invoiced against their purchase order from the first order. We work on quote and invoice, not a checkout. RFQs to sales@cballast.com.

Frequently asked questions

What is the difference between RFOU and BFOU cable?
Both are halogen-free, flame-retardant (IEC 60332-3-22 cat. A), oil- and mud-resistant braided marine cables per NEK 606 on IEC 60092 constructions. BFOU adds fire resistance: a mica barrier on each conductor keeps the circuit alive through IEC 60331 (90 minutes of flame), which is required for emergency consumers. RFOU does not maintain a circuit in fire — it only refuses to spread one.
What does the (i) or (c) mean in RFOU(i) and RFOU(c)?
Screening of instrumentation pairs: (i) means each pair carries its own screen — the choice for analogue 4–20 mA and signal loops; (c) means one collective screen over all pairs, acceptable for digital and alarm circuits where pair-to-pair crosstalk is not critical.
Which shipboard circuits need fire-resistant cable?
Services required to remain operable under fire conditions: fire and emergency fire pumps, emergency generator feeders and controls, steering gear, public address and general alarm, emergency lighting, watertight doors and fire-detection loops. SOLAS II-1/II-2 and the class rules define the list per vessel type; the cable answer is BFOU-class (IEC 60331 verified).
Is IEC 60332-1 enough for marine cable?
No. IEC 60332-1 is a single-cable test; shipboard runs are bunched on ladders, which is the IEC 60332-3-22 category A test. Marine type approvals require the bunched test; a cable citing only 60332-1 is not a shipboard cable.
Can I use land installation cable on a ship?
Only where the yard specification and class accept it — typically dry accommodation spaces — and halogen-free in any case. Machinery spaces, decks and anything within survey scope take IEC 60092 constructions with class type approval. The surveyor asks for the cable certificate, not the invoice.
Who supplies RFOU and BFOU cable in cut lengths with class certificates?
cballast.com quotes Prysmian, Nexans and other approved makers' marine cable by designation, cross-section and cut length, with the class society certificate, glands, lugs and transits in one quote. Send the designation list to sales@cballast.com.

References and related guides

Standards referenced: IEC 60092-350, -351, -352, -353, -376 (shipboard cables); NEK 606 (offshore cable specification); IEC 60332-1-2 and 60332-3-22 (flame tests); IEC 60331-21 (fire resistance); IEC 60754-1/-2 (halogen gases); IEC 61034-2 (smoke); IEC 60228 (conductors); SOLAS II-1/II-2; DNV, LR, ABS, BV, ClassNK rules for classification.

Questions on a designation, a cross-section or a certificate: write to sales@cballast.com. We answer whether or not you buy from us.

Open / Download PDF

Compiled by cBallast for identification and cross-reference. Part numbers, designations and trademarks belong to their respective manufacturers. Confirm ratings and dimensions against the manufacturer's current documentation and the nameplate of the installed equipment before ordering or installation.