Schneider Modicon M221 PLC TM221CE24R 24 I/O Ethernet
Schneider Electric

Schneider Modicon M221 PLC TM221CE24R 24 I/O Ethernet

Part numberTM221CE24RItem numberCB-SCH-046HS code8537.10
IEC 61131-2
MaterialPolycarbonate/ABS housingCE, UL, CSA, RCM, EAC
MOQ:1

Pricing

Request a quote

We reply within 24 hours

Product Description

Schneider Electric TM221CE24R Modicon M221 logic controller, 24 I/O (14 digital inputs incl. 4 fast, 10 relay outputs), embedded Ethernet + serial line, 100-240V AC supply.

Technical Specifications

Series
Modicon M221, digital Inputs: 14 (4 fast 100kHz), digital Outputs: 10 relay, Communication: 1x Ethernet, 1x RS485 serial line, Supply Voltage: 100-240V AC, Expansion: Up to 7 TM3 expansion modules, Programming: EcoStruxure Machine - Basic (free), Mounting: 35mm DIN rail or screw plate Range of product: Modicon M221 Product or component type: Logic controller [Us] rated supply voltage: 100...240 V AC Discrete input number: 14, discrete input conforming to IEC 61131-2 Type 1 Analogue input number: 2 at 0...10 V Discrete output type: Relay normally open Discrete output number: 10 relay Discrete output voltage: 5...125 V DC; 5...250 V AC Discrete output current: 2 A Discrete I/O number: 24 Maximum number of I/O expansion module: 7 (local I/O-Architecture); 14 (remote I/O-Architecture) Supply voltage limits: 85…264 V Network frequency: 50/60 Hz Inrush current: 40 A Maximum power consumption in VA: 58 VA at 100...240 V with max number of I/O expansion module; 35 VA at 100...240 V without I/O expansion module Power supply output current: 0.52 A 5 V for expansion bus; 0.16 A 24 V for expansion bus Discrete input logic: Sink or source (positive/negative) Discrete input voltage: 24 V Discrete input voltage type: DC Analogue input resolution: 10 bits LSB value: 10 mV Conversion time: 1 ms per channel + 1 controller cycle time for analogue input analogue input Permitted overload on inputs: +/- 30 V DC for 5 min (maximum) for analogue input; +/- 13 V DC (permanent) for analogue input Voltage state 1 guaranteed: >= 15 V for input Voltage state 0 guaranteed: <= 5 V for input Discrete input current: 7 mA for discrete input; 5 mA for fast input Input impedance: 3.4 kOhm for discrete input; 100 kOhm for analogue input; 4.9 kOhm for fast input Response time: 35 µs turn-off, I2...I5 terminal(s) for input; 10 ms turn-on for output; 10 ms turn-off for output; 5 µs turn-on, I0, I1, I6, I7 terminal(s) for fast input; 35 µs turn-on, other terminals terminal(s) for input; 5 µs turn-off, I0, I1, I6, I7 terminal(s) for fast input; 100 µs turn-off, other terminals terminal(s) for input Configurable filtering time: 0 ms for input; 3 ms for input; 12 ms for input Output voltage limits: 125 V DC; 277 V AC Maximum current per output common: 4 A at COM 2; 7 A at COM 0; 7 A at COM 1 Absolute accuracy error: +/- 1 % of full scale for analogue input Electrical durability: 100000 cycles AC-12, 120 V, 240 VA, resistive; 100000 cycles AC-12, 240 V, 480 VA, resistive; 300000 cycles AC-12, 120 V, 80 VA, resistive; 300000 cycles AC-12, 240 V, 160 VA, resistive; 100000 cycles AC-15, cos phi = 0.35, 120 V, 60 VA, inductive; 100000 cycles AC-15, cos phi = 0.35, 240 V, 120 VA, inductive; 300000 cycles AC-15, cos phi = 0.35, 120 V, 18 VA, inductive; 300000 cycles AC-15, cos phi = 0.35, 240 V, 36 VA, inductive; 100000 cycles AC-14, cos phi = 0.7, 120 V, 120 VA, inductive; 100000 cycles AC-14, cos phi = 0.7, 240 V, 240 VA, inductive; 300000 cycles AC-14, cos phi = 0.7, 120 V, 36 VA, inductive; 300000 cycles AC-14, cos phi = 0.7, 240 V, 72 VA, inductive; 100000 cycles DC-12, 24 V, 48 W, resistive; 300000 cycles DC-12, 24 V, 16 W, resistive; 100000 cycles DC-13, 24 V, 24 W, inductive (L/R = 7 ms); 300000 cycles DC-13, 24 V, 7.2 W, inductive (L/R = 7 ms) Switching frequency: 20 switching operations/minute with maximum load Mechanical durability: 20000000 cycles for relay output minimum load: 1 mA at 5 V DC for relay output Protection type: Without protection at 5 A Reset time: 1 s Memory capacity: 256 kB for user application and data RAM with 10000 instructions; 256 kB for internal variables RAM Data backed up: 256 kB built-in flash memory for backup of application and data Data storage equipment: 2 GB SD card (optional) Battery type: BR2032 or CR2032X lithium non-rechargeable Backup time: 1 year at 25 °C (by interruption of power supply) Execution time for 1 KInstruction: 0.3 ms for event and periodic task Execution time per instruction: 0.2 µs Boolean Exct time for event task: 60 µs response time Maximum size of object areas: 255 %TM timers; 512 %M memory bits; 8000 %MW memory words; 255 %C counters; 512 %KW constant words Realtime clock: With Clock drift: <= 30 s/month at 25 °C Regulation loop: Adjustable PID controller up to 14 simultaneous loops Counting input number: 4 fast input (HSC mode) at 100 kHz 32 bits counter function: A/B; Single phase; Pulse/direction Integrated connection type: USB port with mini B USB 2.0 connector; Non isolated serial link serial 1 with RJ45 connector and RS232/RS485 interface ; Ethernet with RJ45 connector Supply: (serial)serial link supply: 5 V, <200 mA Transmission rate: 1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 15 m for RS485; 1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m for RS232; 480 Mbit/s for USB Communication port protocol: USB port: USB - SoMachine-Network; Non isolated serial link: Modbus master/slave - RTU/ASCII or SoMachine-Network; Ethernet Port Ethernet: 10BASE-T/100BASE-TX 1 port with 100 m copper cable Communication service: Modbus TCP server; Modbus TCP slave device; DHCP client; Modbus TCP client; Ethernet/IP adapter Local signalling: 1 LED (green) for PWR; 1 LED (green) for RUN; 1 LED (red) for module error (ERR); 1 LED (green) for SD card access (SD); 1 LED (red) for BAT; 1 LED per channel (green) for I/O state; 1 LED (green) for SL; Ethernet network activity (green) for ACT; Ethernet network link (yellow) for Link (Link Status) Electrical connection: removable screw terminal block for inputs; removable screw terminal block for outputs; terminal block, 3 terminal(s) for connecting the 24 V DC power supply; connector, 4 terminal(s) for analogue inputs; Mini B USB 2.0 connector for a programming terminal Maximum cable distance between devices: Shielded cable: <10 m for fast input; Unshielded cable: <30 m for output; Unshielded cable: <30 m for digital input; Unshielded cable: <1 m for analogue input Insulation: Between input and internal logic at 500 V AC; Non-insulated between analogue input and internal logic; Non-insulated between analogue inputs; Between supply and ground at 1500 V AC; Between sensor power supply and ground at 500 V AC; Between input and ground at 500 V AC; Between output and ground at 1500 V AC; Between supply and internal logic at 2300 V AC; Between sensor power supply and internal logic at 500 V AC; Between output and internal logic at 2300 V AC; Between Ethernet terminal and internal logic at 500 V AC; Between supply and sensor power supply at 2300 V AC Marking: CE Sensor power supply: 24 V DC at 250 mA supplied by the controller Mounting support: Top hat type TH35-15 rail conforming to IEC 60715; Top hat type TH35-7.5 rail conforming to IEC 60715; plate or panel with fixing kit Height: 90 mm Depth: 70 mm Width: 110 mm Product weight: 0.395 kg Standards: IEC 61131-2; UL 508; CAN/CSA C22.2 No. 213; IACS E10; ANSI/ISA 12-12-01 Product certifications: LR; cULus; ABS; DNV-GL; EAC; RCM; CE; UKCA; cULus HazLoc Environmental characteristic: Ordinary and hazardous location Resistance to electrostatic discharge: 8 kV in air conforming to IEC 61000-4-2; 4 kV on contact conforming to IEC 61000-4-2 Resistance to electromagnetic fields: 10 V/m 80 MHz...1 GHz conforming to IEC 61000-4-3; 3 V/m 1.4 GHz...2 GHz conforming to IEC 61000-4-3; 1 V/m 2...2.7 GHz conforming to IEC 61000-4-3 Resistance to magnetic fields: 30 A/m 50/60 Hz conforming to IEC 61000-4-8 Resistance to fast transients: 2 kV (power lines) conforming to IEC 61000-4-4; 2 kV (relay output) conforming to IEC 61000-4-4; 1 kV (I/O) conforming to IEC 61000-4-4; 1 kV (Ethernet line) conforming to IEC 61000-4-4; 1 kV (serial link) conforming to IEC 61000-4-4 Surge withstand: 2 kV power lines (AC) common mode conforming to IEC 61000-4-5; 2 kV relay output common mode conforming to IEC 61000-4-5; 1 kV I/O common mode conforming to IEC 61000-4-5; 1 kV shielded cable common mode conforming to IEC 61000-4-5; 0.5 kV power lines (DC) differential mode conforming to IEC 61000-4-5; 1 kV power lines (AC) differential mode conforming to IEC 61000-4-5; 1 kV relay output differential mode conforming to IEC 61000-4-5; 0.5 kV power lines (DC) common mode conforming to IEC 61000-4-5 Resistance to conducted disturbances: 10 V 0.15...80 MHz conforming to IEC 61000-4-6; 3 V 0.1...80 MHz conforming to Marine specification (LR, ABS, DNV, GL); 10 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz) conforming to Marine specification (LR, ABS, DNV, GL) Electromagnetic emission: Conducted emissions - test level: 79 dBμV/m QP/66 dBμV/m AV ( power lines (AC)) at 0.15…0.5 MHz conforming to IEC 55011; Conducted emissions - test level: 73 dBμV/m QP/60 dBμV/m AV ( power lines (AC)) at 0.5…300 MHz conforming to IEC 55011; Conducted emissions - test level: 120...69 dBµV/m QP ( power lines) at 10…150 kHz conforming to IEC 55011; Conducted emissions - test level: 63 dBμV/m QP ( power lines) at 1.5…30 MHz conforming to IEC 55011; Radiated emissions - test level: 40 dBμV/m QP class A ( 10 m) at 30…230 MHz conforming to IEC 55011; Conducted emissions - test level: 79...63 dBμV/m QP ( power lines) at 150…1500 kHz conforming to IEC 55011; Radiated emissions - test level: 47 dBμV/m QP class A ( 10 m) at 200…1000 MHz conforming to IEC 55011 Immunity to microbreaks: 10 ms Ambient air temperature for operation: -10…55 °C (horizontal installation); -10…35 °C (vertical installation) Ambient air temperature for storage: -25…70 °C Relative humidity: 10…95 %, without condensation (in operation); 10…95 %, without condensation (in storage) IP degree of protection: IP20 with protective cover in place Pollution degree: <= 2 Operating altitude: 0...2000 m Storage altitude: 0…3000 m Vibration resistance: 3.5 mm at 5…8.4 Hz on symmetrical rail; 3.5 mm at 5…8.4 Hz on panel mounting; 1 gn at 8.4…150 Hz on symmetrical rail; 1 gn at 8.4…150 Hz on panel mounting Shock resistance: 98 m/s² for 11 ms Number of Units in Package 1: 1 Number of Units in Package 2: 20 Number of Units in Package 3: 240 Country of origin: TW Warranty (in months): 18 EAN: 3606480648779

Standards & Compliance

Standard
IEC 61131-2
Material
Polycarbonate/ABS housing
Temperature Range
0°C to +55°C
Classification / Approval
CE, UL, CSA, RCM, EAC
HS Code
8537.10

Compatibility & Fitment

Compatible with TM3 expansion modules, TMC2 cartridges. Programmed via EcoStruxure Machine - Basic.

Not sure if it fits? Email sales@cballast.com with your equipment serial number or photos — we confirm fit before you order.

Product Documentation

Document preview: Schneider Electric TM221CE24R — OEM Product Page

Catalogue entry last verified: 2026-08-30. A manufacturer datasheet is attached to this entry — confirm application-critical values against it.

Frequently asked questions

Where can I buy TM221CE24R?
TM221CE24R can be ordered from cballast.com as a Schneider Electric catalogue item: request a quotation on this page or email sales@cballast.com, and the order ships worldwide.
What is the manufacturer part number for this Schneider Electric product?
The manufacturer part number is TM221CE24R.
What is the HS code for TM221CE24R?
The customs tariff (HS) code for TM221CE24R is 8537.10.
Who manufactures TM221CE24R?
TM221CE24R is a Schneider Electric product in the Control & Automation range.
Is a datasheet available for TM221CE24R?
Yes — the TM221CE24R datasheet can be viewed and downloaded on this page.
What is the minimum order quantity for TM221CE24R?
The minimum order quantity is 1.
Is TM221CE24R available?
Yes — TM221CE24R is available to order: fulfilment is from supplier stock in cBallast's European network, dispatched directly from the warehouse to the customer, with the exact lead time stated in the quotation (reply within 24 hours).