OWS IS Power-Supply 24 VDC Barrier Single-Channel Zener (replacement)
Generic · Separators & Centrifuges · Oily Water Separator Parts
OWS IS Power-Supply 24 VDC Barrier Single-Channel Zener — intrinsically-safe single-channel zener barrier for ATEX-zone OIW sensor 4-20 mA loop power and.
Specifications
- Part number
- OWS-IS-BAR-SINGLECHANNELZENER
- HS code
- 8421.99
- Material
- DIN-rail mount IP20 housing + 24 VDC supply + 4-20 mA loop-powered barrier + Ex ia IIC T4
Compatibility
Form-fit envelope for ATEX-zone OIW sensor loop powering on Alfa Laval PureBilge, RWO OWS-COM, Heli-Sep + Victor Marine OWS units.
Standards
- IEC 60079-0 explosive atmospheres — equipment — general requirements
- IEC 60079-11 explosive atmospheres — equipment protection by intrinsic safety i
- IEC 60079-25 explosive atmospheres — intrinsically safe electrical systems
- IEC 60529 IP rating
- MEPC.107(49) revised guidelines and specifications for pollution prevention equipment for machinery space bilges
- USCG 33 CFR 162.050 oil-water separators and bilge alarms
- ATEX 2014/34/EU directive on equipment for explosive atmospheres
- IEC 60079-11
- IEC 60079-25
- IEC 60079-0
- IEC 60529
- EN 10204
- MEPC.107
Approvals
- ATEX 2014/34/EU II 1 G Ex ia IIC T4 Ga
- IECEx certified Ex ia IIC T4 Ga
- CE EMC 2014/30/EU
- IACS UR M77/E10 compliant when fitted as like-for-like on certified equipment
- CE
- ATEX
- IECEx
- USCG
- EMC
- MEPC
Separators & Centrifuges · More Generic · Printable datasheet