Gatew.Darw Prof.DPmax 58 SWD's (EU5C-SWD-DP)
Eaton

Gatew.Darw Prof.DPmax 58 SWD's

Part numberEU5C-SWD-DPEAN / GTIN4015081160488HS code8538.90
MOQ:1

Pricing

Request a quote

We reply within 24 hours

Overview

Eaton Gatew.Darw Prof.DPmax 58 SWD's (part number EU5C-SWD-DP) is listed under Control & Automation / Fieldbus I/O. Sales unit: pcs; Eaton catalogue number: 116308; Depth: 127 mm; Height: 90 mm; Width: 35 mm; Weight: 0.157 kg.

Technical Specifications

Manufacturer part number (MPN)
EU5C-SWD-DP
EAN / GTIN
4015081160488
Sales unit
pcs
Eaton catalogue number
116308
Depth
127 mm
Height
90 mm
Width
35 mm
Weight
0.157 kg
Certifications
IEC/EN 61131-2; CSA Class No.: 3211-07; CSA File No.: 2324643; EN 50178; UL File No.: E29184; CSA; UL Category Control No.: NKCR; UL
Constant acceleration
1 g, 8.4 - 150 Hz, according to IEC/EN 61131-2, Vibrations
Constant amplitude
3,5 mm, 5 - 8.4 Hz, according to IEC/EN 61131-2, Vibrations
Drop and topple
50 mm Drop height, Drop to IEC/EN 60068-2-31
Height of fall (IEC/EN 60068-2-32) - max
0.3 m
Mounting position
As required
Shock resistance
15 g, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 11 ms, 9 Impacts
Air pressure
795 - 1080 hPa (operation)
Ambient operating temperature - max
55 °C
Ambient storage temperature - max
70 °C
Ambient operating temperature - min
-25 °C
Ambient storage temperature - min
-40 °C
Climatic proofing
In accordance with IEC 60068-2
Operating temperature - max
55 °C
Operating temperature - min
-25 °C
Relative humidity
5 - 95 % (non-condensing, IEC/EN 60068-2-30)
Addressing
Address range: 1 - 126; Address set automatically
Connection type
SWD: Plug, 8-pole; 1 x D-SUB socket, 9-pin, Field bus; Push in terminals, Supply voltage
Data transfer rate
240 Byte, Fieldbus interface, Output data, max.; 250 kBit/s, SmartWire-DT; Automatic baud rate detection for rates ranging from 9.6 kBit/s to 12 Mbit/s.; 125 kBit/s, SmartWire-DT; 240 Byte, Fieldbus interface, Input data, max.; Up to 12 MBit/s, Fieldbus interface
Interfaces
Module type: PROFIBUS DP slave; Status display fieldbus interface for DP with Multi color LED; Terminating resistor switchable via field bus connectors
LED indicator
Status indication of SmartWire-DT network: Configurable green or red LED; Status indication of SmartWire-DT master: Green and red LEDs; Status indication of Supply voltage: LED
Number of modules
58 (SmartWire-DT)
Protocol
DeviceNet; PROFIBUS-DP
Station
2 - 125, Station address, Fieldbus interface; SmartWire-DT master, SmartWire-DT network
Equipment heat dissipation, current-dependent Pvid
3.8 W
Static heat dissipation, non-current-dependent Pvs
1 W
Inrush current
12.5 A (for 6 ms)
Power loss
Normally 1 W
Rated control supply voltage
24 V DC (UPOW, -15 %/+20 %); 24 V DC (UAUX, -15 %/+20 %)
Rated operational current (Ie)
0.7 A
Rated operational voltage
14.5 V (± 3 % - SmartWire-DT); Typically UAUX -0.2 V (for 24 V DC slaves)
Short-circuit protection
Yes, Short-circuit rating, SmartWire-DT supply voltage; No, external fuse FAZ Z3, Supply voltage UAux
Supply current - max
0.7 mA
Supply voltage at DC - max
28.8 V
Supply voltage at DC - min
20.4 V
Air discharge
8 kV, according to IEC 61131-2, level 3, ESD
Burst impulse
2 kV, Supply cable, according to IEC/EN 61131-2, Level 3; 1 kV; 1 kV, SmartWire-DT cable, according to IEC/EN 61131-2, Level 3
Contact discharge
4 kV, according to IEC/EN 61131-2, Level 2, ESD
Electromagnetic fields
1 V/m at 2.0 - 2.7 GHz (according to IEC/EN 61131-2:2008); 10 V/m at 80 - 1000 MHz (according to IEC/EN 61131-2:2008); 3 V/m at 1.4 - 2 GHz (according to IEC/EN 61131-2:2008)
Radiated RFI
10 V (IEC/EN 61131-2:2008, Level 3)
Radio interference class
Class A (EN 55011)
Surge rating
0.5 kV, Supply cable, Surge (IEC/EN 61131-2:2008, Level 1), EMC
Voltage dips
≤ 10 ms, Bridging voltage dips
Features
Overload proof; Potential isolation (Fieldbus Interface)
Functions
For connection to PROFIBUS-DP field bus
Operating mode
Address allocation via DIP switch
Degree of protection
IP20
Mounting method
Screw fixing using fixing brackets ZB4-101-GF1 (accessories); Top-hat rail fixing (according to IEC/EN 60715, 35 mm); Rail mounting possible; Wall mounting/direct mounting
Overvoltage category
II
Pollution degree
2
Product category
SmartWire-DT coordinators
Repetition rate
1 s
Residual ripple
≤ 5 % (input voltage)
Suitable for
Safety functions
Terminal capacity
0.2 - 1.5 mm², solid; 0.25 - 1.5 mm², flexible with ferrule; 24 - 16 AWG, solid or stranded
Voltage type
DC
Explosion safety category for dust
None
Explosion safety category for gas
None
Potential isolation
Supply voltage UAUX: no; Between UPow and 15 V SmartWire-DT supply voltage: no
Protection against polarity reversal
Yes, for supply voltage (Siemens MPI optional); Yes
Number of HW-interfaces other
1
Number of HW-interfaces RS-232
1
Certified for UL hazardous location division 1
No
Certified for UL hazardous location division 2
No
Certified for UL hazardous location group A (acetylene)
No
Certified for UL hazardous location group B (hydrogen)
No
Certified for UL hazardous location group C (ethylene)
No
Certified for UL hazardous location group D (propane)
No
Certified for UL hazardous location group E (metal dusts)
No
Certified for UL hazardous location class I
No
Certified for UL hazardous location class II
No
Certified for UL hazardous location class III
No
Supporting protocol for EtherCAT
No
Supply voltage DC
20.4–28.8 V
Supporting protocol for TCP/IP
No
Supporting protocol for PROFIBUS
No
Supporting protocol for CAN
No
Supporting protocol for INTERBUS
No
Supporting protocol for ASI
No
Supporting protocol for KNX
No
Supporting protocol for Modbus
No
Supporting protocol for Data-Highway
No
Supporting protocol for DeviceNet
Yes
Supporting protocol for SUCONET
No
Supporting protocol for LON
No
Supporting protocol for SERCOS
No
Supporting protocol for PROFINET IO
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for other bus systems
No
Radio standard Bluetooth
No
Radio standard WLAN 802.11
No
Radio standard GPRS
No
Radio standard eGPRS
No
Radio standard GSM
No
Radio standard LTE
No
Mobile communications standard 3G (UMTS)
No
IO link master
No
System accessory
Yes
With potential separation
No
Fieldbus connection over separate bus coupler possible
No
Suitable for rail mounting
Yes
Wall mounting/direct mounting
Yes
Front built-in possible
No
Rack-assembly possible
No
Suitable for safety functions
Yes

Standards & Compliance

HS Code
8538.90

Cross References

  • EAN 4015081160488
  • SAP 1000288887
  • Code 895181

Product Documentation

Document preview: Gatew.Darw Prof.DPmax 58 SWD's (EU5C-SWD-DP) — Specification Data Sheet (OEM)

Catalogue entry last verified: 2026-09-29. A manufacturer datasheet is attached to this entry — confirm application-critical values against it.

Frequently asked questions

Where can I buy EU5C-SWD-DP?
EU5C-SWD-DP can be ordered from cballast.com as a Eaton catalogue item: request a quotation on this page or email sales@cballast.com, and the order ships worldwide.
What is the manufacturer part number for this Eaton product?
The manufacturer part number is EU5C-SWD-DP.
What is the HS code for EU5C-SWD-DP?
The customs tariff (HS) code for EU5C-SWD-DP is 8538.90.
Who manufactures EU5C-SWD-DP?
EU5C-SWD-DP is a Eaton product in the Control & Automation range.
Is a datasheet available for EU5C-SWD-DP?
Yes — the EU5C-SWD-DP datasheet can be viewed and downloaded on this page.
What is the minimum order quantity for EU5C-SWD-DP?
The minimum order quantity is 1.
Is EU5C-SWD-DP available?
Yes — EU5C-SWD-DP is available to order: fulfilment is from supplier stock in cBallast's European network, dispatched directly from the warehouse to the customer, with the exact lead time stated in the quotation (reply within 24 hours).