Eaton PDIM-40/4 Residual current circuit-breaker, 40A, 4p, 0mA, AC-Char.
Technical Specifications
- Manufacturer part number (MPN)
- PDIM-40/4
- EAN / GTIN
- 4015081113101
- HS code
- 8536.90
- Sales unit
- pcs
- Package quantity
- 30 pcs
- Eaton catalogue number
- 111760
- Depth
- 76 mm
- Height
- 80 mm
- Width
- 70 mm
- Weight
- 0.334 kg
- Compliances
- RoHS conform
- Certifications
- DIN/EN 62020
- Used with
- Leakage current monitor; PDIM
- Amperage Rating
- 40 A
- Features
- Selective protection; Leakage current monitor; Additional equipment possible
- Fitted with
- Interlocking device
- Frame
- 45 mm
- Frequency rating
- 60 Hz
- Pollution degree
- 2
- Lifespan, mechanical
- 20000 operations
- Mounting Method
- Quick attachment with 2 latch positions on top-hat rail IEC/EN 60715; DIN rail
- Climatic proofing
- 25-55 °C / 90-95% relative humidity according to IEC 60068-2
- Equipment heat dissipation, current-dependent
- 2 W
- Rated impulse withstand voltage (Uimp)
- 4 kV
- Rated short-time withstand current (Icw)
- 10 kA
- Admissible back-up fuse overload - max
- 40 A gG/gL
- Built-in width (number of units)
- 70 mm (4 SU)
- Busbar material thickness
- 0.8 mm - 2 mm
- Short-circuit rating
- 63 A (max. admissible back-up fuse)
- Terminal protection
- Finger and hand touch safe, DGUV VS3, EN 50274
- Terminals (top and bottom)
- Twin-purpose terminals
- Ambient operating temperature - max
- 60 °C
- Ambient operating temperature - min
- -25 °C
- Built-in depth
- 60 mm
- Connectable conductor cross section (multi-wired) - max
- 16 mm²
- Connectable conductor cross section (multi-wired) - min
- 1.5 mm²
- Connectable conductor cross section (solid-core) - max
- 35 mm²
- Connectable conductor cross section (solid-core) - min
- 1.5 mm²
- Fault current rating
- 1000 mA
- Heat dissipation capacity
- 0 W
- Heat dissipation per pole, current-dependent
- 0 W
- Permitted storage and transport temperature - max
- 60 °C
- Permitted storage and transport temperature - min
- -35 °C
- Degree of protection
- IP20; IP20, IP40 with suitable enclosure
- Number of poles
- Four-pole
- Leakage current type
- AC
- Lifespan, electrical
- 4000 operations
- Type
- Leakage current monitor PDIM
- Special features
- Current test marks as per inscription Maximum operating temperature is 60 °C: Starting at 40 °C, the max. permissible continuous current decreases by 2.5% for every 1 °C Switching contact (potential-free) 10 A / 240 V~
- Application
- Switchgear for industrial and advanced commercial applications xEffect - Switchgear for industrial and advanced commercial applications
- Functions
- Short-time delayed tripping; Fault current adjustable: 0.03 A/0.1 A/0.3 A/0.5 A/1 A
- Sensitivity type
- AC and pulsating DC current sensitive
- Rated fault current - max
- 1 A
- Rated fault current - min
- 0.03 A
- Rated insulation voltage (Ui)
- 440 V
- Rated operational current for specified heat dissipation (In)
- 40 A
- Rated operational voltage (Ue) - max
- 415 V
- Static heat dissipation, non-current-dependent
- 0 W
- Surge current capacity
- 0.25 kA
- Width in number of modular spacings
- 4
- Voltage rating (IEC/EN 60947-2)
- 230/400 V, 50/60 Hz 240/415 V, 50/60 Hz
- Voltage type
- AC
- Terminal capacity (solid wire)
- 1.5 mm² - 35 mm²
- Tripping time
- 10 ms delayed (Type G); Non-delayed, adjustable; Selective switch off, adjustable; Short time-delayed, adjustable; 40 ms delayed, selective (type S)
- Terminal capacity (control cable)
- 0.25 mm² - 1.5 mm² at switching contacts
- Rated short-circuit strength
- 10 kA
- Response behavior (adjustable)
- Undelayed
- Response behavior of contacts
- 1: 30 - 50 % Iδn; 2: > 50 % IΔn
- Terminal capacity (stranded cable)
- 16 mm² (2x)
- RAL-number
- 7035
- Color
- Gray
Standards & Compliance
- HS Code
- 8536.90
Cross References
- EAN 4015081113101
- SAP 1000707583
- Code 8427908
Product Documentation
Document preview: RESIDUAL CURRENT CIRCUITBREAK. — Specification Data Sheet (OEM)
More from Eaton

Eaton
Eaton NZMN1-4-A160 Molded-Case Circuit Breaker 4-Pole 160A 50KA

Eaton
Shield clamp 1200A 3/4-POLE xE Main (XBST12-1)

Eaton
Connection Module (PKZM0-XDM15ME)

Eaton
Touch Security FOR NH3 32mm
XNH3-XKSS-32

Eaton
Wall-mount cabinet EWK 144 mod H950 B550 D225
EWK-G26/31

Eaton
Led Flashing light, Blue, 24V (SL4-BL24-B)

Eaton
Door whole G2 OvU 2-Row 106 mm
EP-501167

Eaton
Matt black single, Hjemme Borte
CWIZ-01/b9
Catalogue entry last verified: 2026-09-29. A manufacturer datasheet is attached to this entry — confirm application-critical values against it.
Frequently asked questions
- Where can I buy PDIM-40/4?
- PDIM-40/4 can be ordered from cballast.com as a Eaton catalogue item: request a quotation on this page or email sales@cballast.com, and the order ships worldwide.
- What is the manufacturer part number for this Eaton product?
- The manufacturer part number is PDIM-40/4.
- What is the HS code for PDIM-40/4?
- The customs tariff (HS) code for PDIM-40/4 is 8536.90.
- Who manufactures PDIM-40/4?
- PDIM-40/4 is a Eaton product in the Electrical Components range.
- Is a datasheet available for PDIM-40/4?
- Yes — the PDIM-40/4 datasheet can be viewed and downloaded on this page.
- What is the minimum order quantity for PDIM-40/4?
- The minimum order quantity is 1.
- Is PDIM-40/4 available?
- Yes — PDIM-40/4 is available to order: fulfilment is from supplier stock in cBallast's European network, dispatched directly from the warehouse to the customer, with the exact lead time stated in the quotation (reply within 24 hours).