
Eaton
Cam switch, On/Off (P3-63/IVS)
Part numberP3-63/IVSEAN / GTIN4015080410997HS code8536.90
Switchgear & Protection
Disconnect Switches
MOQ:1
Pricing
Request a quote
We reply within 24 hours
Product Description
Eaton P3-63/IVS Switch, bottom-mounted module, front IP 30.
Technical Specifications
- Manufacturer part number (MPN)
- P3-63/IVS
- EAN / GTIN
- 4015080410997
- HS code
- 8536.90
- Sales unit
- pcs
- Eaton catalogue number
- 041099
- Depth
- 87 mm
- Height
- 83 mm
- Width
- 72 mm
- Weight
- 0.287 kg
- Certifications
- UL; UL File No.: E36332; IEC/EN 60204; CSA File No.: 012528; VDE 0660; UL 60947-4-1; CSA; IEC/EN 60947; CE; UL Category Control No.: NLRV; CSA Class No.: 3211-05; IEC/EN 60947-3; CSA-C22.2 No. 60947-4-1-14; CSA-C22.2 No. 94
- Catalog Notes
- Rated Short-time Withstand Current (Icw) for a time of 1 second
- Actuator color
- Black
- Actuator type
- Short thumb-grip
- Ambient operating temperature - max
- 50 °C
- Ambient operating temperature - min
- -25 °C
- Ambient operating temperature (enclosed) - max
- 40 °C
- Ambient operating temperature (enclosed) - min
- -25 °C
- Climatic proofing
- Damp heat, constant, to IEC 60068-2-78; Damp heat, cyclic, to IEC 60068-2-30
- Control circuit reliability
- 1 failure per 100,000 switching operations statistically determined, at 24 V DC, 10 mA)
- Number of auxiliary contacts (change-over contacts)
- 0
- Number of auxiliary contacts (normally closed contacts)
- 0
- Number of auxiliary contacts (normally open contacts)
- 0
- Equipment heat dissipation, current-dependent Pvid
- 0 W
- Heat dissipation capacity Pdiss
- 0 W
- Heat dissipation per pole, current-dependent Pvid
- 4.5 W
- Rated operational current for specified heat dissipation (In)
- 63 A
- Static heat dissipation, non-current-dependent Pvs
- 0 W
- Rated breaking capacity at 220/230 V (cos phi to IEC 60947-3)
- 640 A
- Rated breaking capacity at 400/415 V (cos phi to IEC 60947-3)
- 600 A
- Rated breaking capacity at 500 V (cos phi to IEC 60947-3)
- 590 A
- Rated breaking capacity at 660/690 V (cos phi to IEC 60947-3)
- 340 A
- Rated operational current (Ie) at AC-21, 440 V
- 63 A
- Rated operational current (Ie) at AC-23A, 230 V
- 63 A
- Rated operational current (Ie) at AC-23A, 400 V, 415 V
- 63 A
- Rated operational current (Ie) at AC-23A, 500 V
- 63 A
- Rated operational current (Ie) at AC-23A, 690 V
- 63 A
- Rated operational current (Ie) at AC-3, 220 V, 230 V, 240 V
- 51 A
- Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V
- 55 A
- Rated operational current (Ie) at AC-3, 500 V
- 44 A
- Rated operational current (Ie) at AC-3, 660 V, 690 V
- 22.1 A
- Rated operational current (Ie) at DC-23A, 120 V
- 25 A
- Rated operational current (Ie) at DC-23A, 24 V
- 50 A
- Rated operational current (Ie) at DC-23A, 48 V
- 50 A
- Rated operational current (Ie) at DC-23A, 60 V
- 50 A
- Rated operational power at AC-23A, 220/230 V, 50 Hz
- 18.5 kW
- Rated operational power at AC-23A, 400 V, 50 Hz
- 30 kW
- Rated operational power at AC-23A, 500 V, 50 Hz
- 45 kW
- Rated operational power at AC-23A, 690 V, 50 Hz
- 55 kW
- Rated operational power at AC-3, 380/400 V, 50 Hz
- 30 kW
- Rated operational power at AC-3, 415 V, 50 Hz
- 30 kW
- Rated operational power at AC-3, 690 V, 50 Hz
- 30 kW
- Rated operational voltage (Ue) at AC - max
- 690 V
- Rated uninterrupted current (Iu)
- 63 A
- Uninterrupted current
- Rated uninterrupted current Iu is specified for max. cross-section.
- Fitted with
- Black thumb grip and front plate
- Locking facility
- Lockable in the 0 (Off) position
- Number of poles
- 3
- Accessories
- Auxiliary contact or neutral conductor fitted by user.
- Degree of protection
- NEMA Other
- Degree of protection (front side)
- IP30
- Lifespan, mechanical
- 100,000 Operations
- Mounting method
- Service distribution board mounting
- Mounting position
- As required
- Operating frequency
- 1200 Operations/h
- Overvoltage category
- III
- Pollution degree
- 3
- Product Category
- On-Off switch
- Rated impulse withstand voltage (Uimp)
- 6000 V AC
- Safe isolation
- 440 V AC, Between the contacts, According to EN 61140
- Safety parameter (EN ISO 13849-1)
- B10d values as per EN ISO 13849-1, table C.1
- Shock resistance
- 15 g, Mechanical, According to IEC/EN 60068-2-27, Half-sinusoidal shock 20 ms
- Suitable for
- Branch circuits, suitable as motor disconnect, (UL/CSA); Distribution board installation; Ground mounting
- Assigned motor power at 115/120 V, 60 Hz, 1-phase
- 3 HP
- Assigned motor power at 200/208 V, 60 Hz, 1-phase
- 7.5 HP
- Assigned motor power at 200/208 V, 60 Hz, 3-phase
- 15 HP
- Assigned motor power at 230/240 V, 60 Hz, 1-phase
- 10 HP
- Assigned motor power at 230/240 V, 60 Hz, 3-phase
- 15 HP
- Assigned motor power at 460/480 V, 60 Hz, 3-phase
- 40 HP
- Assigned motor power at 575/600 V, 60 Hz, 3-phase
- 50 HP
- Rated conditional short-circuit current (Iq)
- 4 kA (Load side); 100 kA (Supply side)
- Rated short-time withstand current (Icw)
- 1.26 kA
- Short-circuit current rating (basic rating)
- 10 kA, SCCR (UL/CSA); 150A, max. Fuse, SCCR (UL/CSA)
- Short-circuit protection rating
- 80 A gG/gL, Fuse, Contacts
- Load rating
- 2 x Iₑ (with intermittent operation class 12, 25 % duty factor); 1.6 x Iₑ (with intermittent operation class 12, 40 % duty factor); 1.3 x Iₑ (with intermittent operation class 12, 60 % duty factor)
- Number of contacts in series at DC-23A, 120 V
- 3
- Number of contacts in series at DC-23A, 24 V
- 1
- Number of contacts in series at DC-23A, 48 V
- 2
- Number of contacts in series at DC-23A, 60 V
- 2
- Rated making capacity up to 690 V (cos phi to IEC/EN 60947-3)
- 800 A
- Switching capacity (auxiliary contacts, general use)
- 10A, IU, (UL/CSA)
- Switching capacity (auxiliary contacts, pilot duty)
- P600 (UL/CSA); A600 (UL/CSA)
- Switching capacity (main contacts, general use)
- 60 A, Rated uninterrupted current max. (UL/CSA)
- Voltage per contact pair in series
- 60 V
- Screw size
- M5, Terminal screw
- Terminal capacity
- 1 x (2.5 - 35) mm², solid or stranded; 2 x (2.5 - 10) mm², solid or stranded; 1 x (1.5 - 25) mm², flexible with ferrules to DIN 46228; 2 x (1.5 - 6) mm², flexible with ferrules to DIN 46228; 14 - 2 AWG, solid or flexible with ferrule
- Tightening torque
- 3 Nm, Screw terminals; 26.5 lb-in, Screw terminals
Standards & Compliance
- HS Code
- 8536.90
Cross References
- EAN 4015080410997
- SAP 1000071815
- Code 8766022
Product Documentation
Document preview: Kamswitch, On/Of (P3-63/IVS) — Specification Data Sheet (OEM)
More from Eaton

Eaton
Rotary switch with light, Flat Front (M30C-FWRLK-R)

Eaton
Unit breaker 1P 125A C
AZ-C125

Eaton
Meter Panel 2 meter MOK H600 B600 xE Basic
2457642

Eaton
Eaton CWIZ-02/68 Double Rocker, Matt Signal White, Ventilation

Eaton
Eaton FAZ-D63/1 Miniature Circuit Breaker — 1P, Type D, 63 A, 15 kA

Eaton
Eaton 183011 Double Cable Clamp
XNH2-X2PRC

Eaton
Mounting Frame and screws (DXG-ACC-FR5N12FK)

Eaton
Window Contact Varmwhite
CDWA-01/3a
Catalogue entry last verified: 2026-09-30. A manufacturer datasheet is attached to this entry — confirm application-critical values against it.
Frequently asked questions
- Where can I buy P3-63/IVS?
- P3-63/IVS can be ordered from cballast.com as a Eaton catalogue item: request a quotation on this page or email sales@cballast.com, and the order ships worldwide.
- What is the manufacturer part number for this Eaton product?
- The manufacturer part number is P3-63/IVS.
- What is the HS code for P3-63/IVS?
- The customs tariff (HS) code for P3-63/IVS is 8536.90.
- Who manufactures P3-63/IVS?
- P3-63/IVS is a Eaton product in the Switchgear & Protection range.
- Is a datasheet available for P3-63/IVS?
- Yes — the P3-63/IVS datasheet can be viewed and downloaded on this page.
- What is the minimum order quantity for P3-63/IVS?
- The minimum order quantity is 1.
- Is P3-63/IVS available?
- Yes — P3-63/IVS is available to order: fulfilment is from supplier stock in cBallast's European network, dispatched directly from the warehouse to the customer, with the exact lead time stated in the quotation (reply within 24 hours).
