Coriolis Mass Flow Meter DN40 (1-1/2") — 316L Wetted, 4-20 mA + HART
Generic · Instrumentation · Flow Meters
Twin-tube Coriolis mass flow and density meter for hydrocarbons, chemicals, bunker fuel.
Specifications
- Part number
- CFM-CORI-DN40-316L-HART
- HS code
- 9026.10
- Material
- 316L stainless steel
Compatibility
Form-fit envelope of Endress+Hauser Promass F / Promass Q / Promass 80F, Emerson Micro Motion CMF, KROHNE OPTIMASS 6400/7400 and Yokogawa ROTAMASS DN40 Coriolis meters. Aftermarket Coriolis meters with matching tube geometry can be drop-installed on the same flange face and signal-wired into existing HART loops without skid rework.
Standards
- OIML R117-1
- MID MI-005 (custody transfer)
- API MPMS Ch. 5.6 (Coriolis)
- IEC 61298 series
- IEC 60079-0 / -1 / -11 (Ex variant)
- ISO 10474 3.1 certificate
- ISO 10474
- IEC 17025
- IEC 61298
- IEC 60079-0
- EN 1092-1
- ASME B16.5
- NEMA 4X
Approvals
- CE PED 2014/68/EU module H
- CE ATEX 2014/34/EU (Ex variant)
- IECEx Ex d/Ex ia (variant)
- MID MI-005 examination certificate
- Class society type approval (DNV / LR / ABS / BV / ClassNK / RINA / KR — variant-specific)
- CE
- DNV
- LR
- ABS
- BV
- ClassNK
- RINA
- KR
- ATEX
- IECEx
- PED
Instrumentation · More Generic · Printable datasheet