Thermal Imaging Cameras — Resolution, NETD and Selection

Selection guide compiled by cBallast. 8-page PDF; the full content is on this page.
Compiled by
cBallast
Subject
Thermal imaging cameras
Document type
Selection guide
Reference
2026 edition
Issued
2026-11-09
Pages
8
Format
Web page and PDF

Choosing a thermal imaging camera by the numbers that matter: detector resolution against working distance (spot size ratio), thermal sensitivity (NETD), temperature range, lens and field of view, emissivity and reflected temperature as the error sources, electrical and mechanical survey practice including IR windows and safety distance, camera tiers from smartphone attachments to 640x480 professional units, and reporting that survives an insurer's reading.

The short version

1. The four numbers on every datasheet, ranked

SpecWhat it meansWorking guidance
Detector resolutionIR pixels (160x120 … 640x480)With IFOV ~1.3 mrad class optics, a 320x240 camera measures a 10 mm target reliably at roughly 2–3 m; halve the distance or double the pixels for smaller targets — that is the spot-size arithmetic
NETDSmallest temperature difference the detector resolves (mK)≤ 60 mK general; ≤ 40 mK for low-contrast work
Temperature rangeCalibrated spans−20…+150 °C covers buildings/electrical LV; +650 °C spans motors, steam, most industry; 1,200 °C+ for furnaces and brazing-adjacent work
Lens / FOVInterchangeable optics on pro tiersTelephoto for switchyards and high trays; wide for rooms; fixed-lens cameras lock your working distances

Accuracy quoted as ±2 °C or ±2% is standard across tiers — it is emissivity and reflection handling, not datasheet accuracy, that separates good surveys from noise.

2. Emissivity and reflected temperature, practically

SurfaceTypical emissivityPractice
Electrical tape, paint (non-metallic)0.93–0.96The reference targets — tape a spot where routine measurement is needed
Cable insulation, rubber0.90–0.95Measure the cable near the lug rather than the shiny lug
Oxidised steel, rusted surfaces0.7–0.9Usable with care
Oxidised copper≈ 0.6–0.8Variable; verify with tape where it matters
Polished aluminium, new copper, stainless0.05–0.3Mirrors for infrared: readings are mostly reflected scene — do not report numbers off bare bright metal

Reflected apparent temperature is the second dial: in a 20 °C room it is benign; facing a hot engine block or the open sky it shifts low-emissivity readings by tens of degrees. The method (ISO 18434 thermography practice and every maker's manual agree): set emissivity for the actual target surface, measure and set reflected apparent temperature, keep the viewing angle inside ≈60° from normal, and state both settings in the report.

3. Electrical surveys: method and severity

The survey that finds faults: equipment under ≥ 40% load (record the actual current — severity is load-corrected since heating scales with I²), compare phases of the same circuit, image terminations, fuse holders (NH and cylindrical fuse gear is a classic finding), contactor and breaker terminals, busbar joints and cable lugs (crimp quality shows thermally). Severity banding used across the industry: delta-T against similar component under similar load of 1–3 K: watch; 4–15 K: plan repair; >15 K: repair now — with the site's own criticality overlay. Safety: imaging requires line of sight; opening live boards trades a survey for an arc-flash exposure. The professional pattern is IR windows fitted on switchboards at build or retrofit, imaged closed, with the window's transmission factored in — or imaging during planned de-energised verification. Motor and mechanical work reads bearings, couplings and belts against their twins (pair findings with alignment and bearing follow-ups); refrigeration and building surveys live at the sensitive-NETD end.

4. Camera tiers and who they serve

TierResolution classCatalogue exampleServes
Smartphone attachment160x120FLIR ONE Pro (USB-C)Screening, documentation of the obvious, every supervisor's pocket
Pocket camera120x90 … 160x120, ruggedFluke PTI120, HIK PocketEElectricians' daily checks, quick fault confirmation
Mid handheld256x192 … 320x240FLIR Ex/Exx class and equivalentsRoutine plant surveys at normal working distances
Professional464x348 … 640x480, interchangeable lensesFLIR T540 classSurvey programmes, switchyards, reports to insurers and class

The tier question is the same use-pattern arithmetic as videoscopes and calibrators: screening lives low, evidence lives high. One professional unit shared by a reliability group plus pocket units distributed widely beats a drawer of mid-tier cameras nobody owns.

5. Reports that hold up

A thermography finding that survives scrutiny carries: the radiometric image and a visual photo, target identification (panel, circuit, phase), load at the time, emissivity and reflected temperature settings, distance and lens, the comparison reference (twin phase or twin machine), delta-T, severity band and recommended action, and the camera's identity with its calibration status — thermal cameras are calibrated instruments on 1–2 year cycles like any other reference (traceability logic here). Insurers and class surveyors increasingly ask for exactly this structure; cameras in the mid tier upward generate it natively.

How buying works at cballast. We quote thermal cameras across the tiers with lenses, IR windows and calibration certificates itemised, against the survey programme they will serve. Accounts are vetted at onboarding; first order prepaid; established accounts on credit terms with repeat discounts; public bodies and utilities invoiced against purchase order from the first order. RFQs to sales@cballast.com.

Frequently asked questions

What thermal camera resolution do I need?
Enough pixels on the smallest target at your real working distance: 160x120 screens at arm's length; 320x240 measures standard electrical components at 2–3 m; 640x480 or a telephoto lens for switchyards, high cable trays and small targets at distance. Work the spot-size arithmetic before buying, not after.
What is NETD on a thermal camera?
Noise-equivalent temperature difference: the smallest temperature difference the detector distinguishes from noise, quoted in millikelvin. 60–80 mK serves electrical fault-finding; 40 mK and better pays off on building fabric, refrigeration and slight mechanical gradients where defects are fractions of a degree.
Why does a shiny busbar read cold when it is hot?
Low emissivity: polished metal emits poorly and reflects the room instead, so the camera reports the reflected scene. Measure on adjacent insulation, oxidised or taped surfaces (emissivity ~0.95), set the camera's emissivity and reflected apparent temperature accordingly, and never report absolute numbers off bright bare metal.
What temperature rise on an electrical connection is serious?
Compared with its twin phase under the same load: 1–3 K is worth watching, 4–15 K is a planned repair, above 15 K is an act-now finding — corrected for load, since a fault at 30% load grows as the square of current. Absolute temperature alone, without load and comparison, is not a finding.
Can I survey a switchboard without opening it?
Through installed IR windows, yes — that is their purpose, and retrofitting them to critical boards converts every future survey from an arc-flash exposure into a routine scan. Plastic covers and steel doors are opaque to thermal cameras; "scanning the closed door" images the door.
Who supplies FLIR, Fluke and Hikmicro thermal cameras?
cballast.com quotes thermal cameras from pocket to professional tier, IR windows, lenses and calibration, matched to the survey programme described. Write the use case to sales@cballast.com.

References and related guides

Standards and sources referenced: ISO 18434-1 (thermography in condition monitoring); IEC 62446-3 (thermography context for PV); NETA/industry delta-T severity practice; maker documentation for FLIR, Fluke and Hikmicro ranges; NFPA 70E arc-flash context for live-panel work.

Questions on a tier, a lens or an IR window: write to sales@cballast.com. We answer whether or not you buy from us.

Open / Download PDF

Compiled by cBallast for identification and cross-reference. Part numbers, designations and trademarks belong to their respective manufacturers. Confirm ratings and dimensions against the manufacturer's current documentation and the nameplate of the installed equipment before ordering or installation.