The old British table-flange system that still runs through older tonnage, Commonwealth-built plant and Australian industry: what Tables D, E, F and H mean, dimension data for the common Table E sizes, how BS 10 relates to AS 2129 and to nothing else, field identification by OD, bolt circle and hole count, and the honest replacement paths when a hundred-year-old drilling has to meet a modern EN or ASME valve.
| Table | Duty class (nominal) | Typical service where you meet it | Modern replacement thinking |
|---|---|---|---|
| Table A / C | Very low pressure | Vent and drainage work on heritage plant | PN6 class duty — PN6 chart |
| Table D | Low pressure (~7 bar class) | Cooling water, bilge and ballast on older tonnage, irrigation in AU/NZ | PN10 class duty — PN10 chart |
| Table E | Medium (~14 bar class) — the standard table | General piping, sea water, fuel, steam to moderate conditions; the default on Commonwealth-built ships | PN16 class duty — PN16 chart |
| Table F | Higher (~21 bar class) | Boiler and feed service on older steam plant | PN25 class duty — PN25 chart |
| Table H | High (~35 bar class) | High-pressure steam, some hydraulic-adjacent service | PN40 class duty — PN40 chart |
The "nominal bar class" column is orientation, not a rating: as with PN and JIS K classes, allowable pressure depends on material and temperature. The structural point is simpler — each table is a distinct drilling family, and the table letter plus the pipe size defines the joint completely.
| Nominal size | DN ref | Flange OD (mm) | Bolt circle PCD (mm) | Bolt holes | Bolts (typical) |
|---|---|---|---|---|---|
| 1/2" | 15 | 95 | 67 | 4 | M12 (1/2") |
| 3/4" | 20 | 105 | 73 | 4 | M12 (1/2") |
| 1" | 25 | 115 | 83 | 4 | M12 (1/2") |
| 1 1/4" | 32 | 120 | 87 | 4 | M12 (1/2") |
| 1 1/2" | 40 | 135 | 98 | 4 | M12 (1/2") |
| 2" | 50 | 165 | 127 | 4 | M16 (5/8") |
| 2 1/2" | 65 | 185 | 146 | 4 | M16 (5/8") |
| 3" | 80 | 205 | 165 | 4 | M16 (5/8") |
| 4" | 100 | 230 | 191 | 8 | M16 (5/8") |
| 5" | 125 | 280 | 235 | 8 | M16 (5/8") |
| 6" | 150 | 305 | 260 | 8 | M20 (3/4") |
Values as carried in the AS 2129 continuation of the table system; BS 10 originals were tabulated in inches and the millimetre figures are the standard conversions used by the current supply chain. Two honest caveats for a working buyer. First, larger sizes and Tables D, F and H have their own lines — bolt counts and PCDs step at different points per table, so for sizes beyond this chart or for a D/F/H joint, send us the four measured numbers and we confirm against the standard before quoting; guessing a continuation pattern is how mis-drilled spools get made. Second, hole diameters on old flanges wander: a century of repaints and re-drills means the vernier, not the table, is the last word on what is actually on the pipe.
| Symptom | Likely identity | Confirm by |
|---|---|---|
| 2" line, OD ~165 mm, PCD ~127 mm, 4 holes | Table E 2" (PN16 DN50 is 165/125/4 — the classic near-miss) | PCD to the millimetre: 127 vs 125; imperial bolts in the holes |
| 3" line, OD ~205, PCD ~165, 4 holes | Table E 3" (PN16 DN80 is 200/160/8 — different count) | Hole count settles it instantly |
| 4" line, OD ~230, PCD ~191, 8 holes | Table E 4" (PN16 DN100: 220/180/8; Class 150 4": 229/190.5/8) | Class 150 4" is the dangerous twin — 229/190.5 vs 230/191. Check the raised face and bolt size (5/8" UNC vs metric), and the ship's build history |
| Imperial bolts (Whitworth/UNC) throughout the system | Table-system or ASME heritage, not EN | Thread gauge on a removed stud |
The Class 150 overlap at 4" (and near-misses at other sizes) is the single most instructive case in flange identification: two standards, one millimetre apart, both plausible on an old ship. The build region decides — British/Commonwealth yard suggests Table E, American-influenced plant suggests Class 150 — and the bolt threads betray the system even when the drilling is ambiguous.
Gaskets cut to the table pattern: ring gaskets inside the bolt circle for raised-face joints, full-face with bolt holes for flat-face cast work (common on Table D/E valve bodies). Material selection follows duty exactly as for any flange — the gasket material guide and Klingersil grade reference apply unchanged; only the cut pattern is special, and we cut to measured dimensions. Bolting: original systems carry imperial studs; replacement practice is either like-for-like imperial (we quote UNC stud sets with nuts) or a documented change to metric on a re-drilled joint — never metric bolts rattling in oversized imperial holes on pressure service. Transitions to modern equipment use the same two honest paths as any cross-standard joint: a spool drilled Table E one end and EN/ASME the other, or a counter-flange drilled to the table pattern against the modern body. Blank and spectacle positions for surveys are cut to the same patterns. For valves, actuated packages and strainers onto table-drilled lines, say so in the RFQ — "AS 2129 Table E drilling" is a normal line item for the pattern's supply chain, not an exotic request.
How buying works at cballast. We quote table-pattern flanges, cut gaskets, imperial stud sets and transition spools alongside the EN, ASME and JIS programme — one survey of the joint (four numbers and the material) and the quote comes back correct. Accounts are vetted at onboarding; first order prepaid; established accounts on credit terms with repeat discounts; public bodies and utilities invoiced against purchase order from the first order. RFQs to sales@cballast.com.
Standards and sources referenced: BS 10 (withdrawn; tables of historic record); AS 2129 (current Australian continuation — Tables A to T); EN 1092-1; ASME B16.5; EN 10204. Table E figures per the AS 2129 supply chain's published tables; for safety-critical or survey work confirm against the current AS 2129 edition and the measured joint.
Questions on an unidentified drilling or a transition detail: write to sales@cballast.com. We answer whether or not you buy from us.