BS 10 Table D, E, F Flange Dimensions & Identification

Reference compiled by cBallast. 8-page PDF; the full content is on this page.
Compiled by
cBallast
Subject
BS 10 / AS 2129 table flanges
Document type
Reference
Reference
2026 edition
Issued
2026-11-09
Pages
8
Format
Web page and PDF

The old British table-flange system that still runs through older tonnage, Commonwealth-built plant and Australian industry: what Tables D, E, F and H mean, dimension data for the common Table E sizes, how BS 10 relates to AS 2129 and to nothing else, field identification by OD, bolt circle and hole count, and the honest replacement paths when a hundred-year-old drilling has to meet a modern EN or ASME valve.

The short version

1. The table system in one table

TableDuty class (nominal)Typical service where you meet itModern replacement thinking
Table A / CVery low pressureVent and drainage work on heritage plantPN6 class duty — PN6 chart
Table DLow pressure (~7 bar class)Cooling water, bilge and ballast on older tonnage, irrigation in AU/NZPN10 class duty — PN10 chart
Table EMedium (~14 bar class) — the standard tableGeneral piping, sea water, fuel, steam to moderate conditions; the default on Commonwealth-built shipsPN16 class duty — PN16 chart
Table FHigher (~21 bar class)Boiler and feed service on older steam plantPN25 class duty — PN25 chart
Table HHigh (~35 bar class)High-pressure steam, some hydraulic-adjacent servicePN40 class duty — PN40 chart

The "nominal bar class" column is orientation, not a rating: as with PN and JIS K classes, allowable pressure depends on material and temperature. The structural point is simpler — each table is a distinct drilling family, and the table letter plus the pipe size defines the joint completely.

2. Table E dimensions — the common sizes

Nominal sizeDN refFlange OD (mm)Bolt circle PCD (mm)Bolt holesBolts (typical)
1/2"1595674M12 (1/2")
3/4"20105734M12 (1/2")
1"25115834M12 (1/2")
1 1/4"32120874M12 (1/2")
1 1/2"40135984M12 (1/2")
2"501651274M16 (5/8")
2 1/2"651851464M16 (5/8")
3"802051654M16 (5/8")
4"1002301918M16 (5/8")
5"1252802358M16 (5/8")
6"1503052608M20 (3/4")

Values as carried in the AS 2129 continuation of the table system; BS 10 originals were tabulated in inches and the millimetre figures are the standard conversions used by the current supply chain. Two honest caveats for a working buyer. First, larger sizes and Tables D, F and H have their own lines — bolt counts and PCDs step at different points per table, so for sizes beyond this chart or for a D/F/H joint, send us the four measured numbers and we confirm against the standard before quoting; guessing a continuation pattern is how mis-drilled spools get made. Second, hole diameters on old flanges wander: a century of repaints and re-drills means the vernier, not the table, is the last word on what is actually on the pipe.

3. Identification in the field

SymptomLikely identityConfirm by
2" line, OD ~165 mm, PCD ~127 mm, 4 holesTable E 2" (PN16 DN50 is 165/125/4 — the classic near-miss)PCD to the millimetre: 127 vs 125; imperial bolts in the holes
3" line, OD ~205, PCD ~165, 4 holesTable E 3" (PN16 DN80 is 200/160/8 — different count)Hole count settles it instantly
4" line, OD ~230, PCD ~191, 8 holesTable E 4" (PN16 DN100: 220/180/8; Class 150 4": 229/190.5/8)Class 150 4" is the dangerous twin — 229/190.5 vs 230/191. Check the raised face and bolt size (5/8" UNC vs metric), and the ship's build history
Imperial bolts (Whitworth/UNC) throughout the systemTable-system or ASME heritage, not ENThread gauge on a removed stud

The Class 150 overlap at 4" (and near-misses at other sizes) is the single most instructive case in flange identification: two standards, one millimetre apart, both plausible on an old ship. The build region decides — British/Commonwealth yard suggests Table E, American-influenced plant suggests Class 150 — and the bolt threads betray the system even when the drilling is ambiguous.

4. Living with it: gaskets, bolts, transitions

Gaskets cut to the table pattern: ring gaskets inside the bolt circle for raised-face joints, full-face with bolt holes for flat-face cast work (common on Table D/E valve bodies). Material selection follows duty exactly as for any flange — the gasket material guide and Klingersil grade reference apply unchanged; only the cut pattern is special, and we cut to measured dimensions. Bolting: original systems carry imperial studs; replacement practice is either like-for-like imperial (we quote UNC stud sets with nuts) or a documented change to metric on a re-drilled joint — never metric bolts rattling in oversized imperial holes on pressure service. Transitions to modern equipment use the same two honest paths as any cross-standard joint: a spool drilled Table E one end and EN/ASME the other, or a counter-flange drilled to the table pattern against the modern body. Blank and spectacle positions for surveys are cut to the same patterns. For valves, actuated packages and strainers onto table-drilled lines, say so in the RFQ — "AS 2129 Table E drilling" is a normal line item for the pattern's supply chain, not an exotic request.

How buying works at cballast. We quote table-pattern flanges, cut gaskets, imperial stud sets and transition spools alongside the EN, ASME and JIS programme — one survey of the joint (four numbers and the material) and the quote comes back correct. Accounts are vetted at onboarding; first order prepaid; established accounts on credit terms with repeat discounts; public bodies and utilities invoiced against purchase order from the first order. RFQs to sales@cballast.com.

Frequently asked questions

What is a BS 10 Table E flange?
A flange drilled to Table E of the historic British standard BS 10 — the medium-pressure workhorse table of the old British system, continued today in Australia and New Zealand as AS 2129 Table E with the same dimensions. On older Commonwealth-built ships it is the default general-service flange.
Is Table E the same as PN16?
No. The duty class is comparable, but the drilling is different — Table E 2" is 165 mm OD on a 127 mm bolt circle with 4 holes, where PN16 DN50 is 165 on 125 with 4. Two millimetres of PCD is the difference between a joint and a forced, leaking misfit. Transition with a spool or a re-drilled counter-flange.
How do I identify a Table D, E or F flange?
Measure flange OD and bolt-circle diameter, count holes, measure one hole, and note whether the bolts are imperial. Check those numbers against the table data above (and the PN/Class/JIS charts to exclude the other systems). On this standard more than any other, measure rather than trust a drawing — a century of refits means mixed tables on one ship.
Are BS 10 flanges still available?
Yes — because AS 2129 keeps the pattern current, table-drilled flanges, gaskets and stud sets remain ordinary catalogue items in that supply chain, and any competent flange mill drills the pattern to order. State the table, size, type (plate, slip-on, blank) and material, and certificate level (EN 10204 3.1 for pressure service).
What gasket fits a Table E flange?
The same materials you would select for the duty on any modern flange — compressed fibre, PTFE class or graphite per the media and temperature — cut to the Table E ring or full-face pattern for the size. Send OD, PCD, hole count and pipe bore and we cut to measure.
Who supplies BS 10 / AS 2129 pattern flanges in Europe?
cballast.com quotes table-pattern flanges, transition spools, cut gaskets and imperial bolting against measured dimensions, alongside EN 1092-1, ASME B16.5 and JIS B2220 so mixed-heritage ships deal with one supplier. Write to sales@cballast.com with the four measurements.

References and related guides

Standards and sources referenced: BS 10 (withdrawn; tables of historic record); AS 2129 (current Australian continuation — Tables A to T); EN 1092-1; ASME B16.5; EN 10204. Table E figures per the AS 2129 supply chain's published tables; for safety-critical or survey work confirm against the current AS 2129 edition and the measured joint.

Questions on an unidentified drilling or a transition detail: write to sales@cballast.com. We answer whether or not you buy from us.

Open / Download PDF

Compiled by cBallast for identification and cross-reference. Part numbers, designations and trademarks belong to their respective manufacturers. Confirm ratings and dimensions against the manufacturer's current documentation and the nameplate of the installed equipment before ordering or installation.