The Klingersil compressed-fibre gasket sheet grades decoded — C-4400, C-4430, C-4500, C-4509, C-4324 and the specialty grades — with fibre and binder chemistry, media suitability, the pT-diagram logic that actually governs temperature and pressure limits, sheet thickness selection, equivalents thinking across Garlock, Donit and Temacs class materials, PTFE (Gylon class) and graphite alternatives, and cut-gasket against sheet buying.
| Grade | Fibre / binder | Character | Typical media | Catalogue anchors |
|---|---|---|---|---|
| C-4400 | Aramid / NBR | The universal grade; broad chemical window, good mechanical strength | Water, seawater, oils, fuels, gases, moderate steam duty per pT | C-4400 sheet 1/16" x 59" x 59"; cut gaskets e.g. DN15 PN16, DN20 PN16 |
| C-4430 | Aramid + glass / NBR | Higher load-bearing and steam capability than C-4400 | Steam per pT, hot water, oils, gases — the plant upgrade grade | C-4430 sheet 1/16" x 59" x 59" |
| C-4500 | Carbon / NBR | Temperature capability above the aramid grades | Hot oils, heat-transfer duties, steam per pT | Quoted by sheet or cut gasket |
| C-4509 | Carbon / NBR (oil-service recipe) | Heat plus hydrocarbon resistance | Thermal oil, hot hydrocarbon lines | Quoted by sheet or cut gasket |
| C-4324 | Aramid / NBR (economy) | General service where duty is mild and price matters | Water, air, oils at modest pT | C-4324 sheet 1500 x 1000 x 2.0 mm |
Adjacent Klinger families complete the picture: Klinger ML1 universal sheet for undemanding service (ML1 1500 x 1000 x 2 mm), top-sil and top-chem engineered sheets — the top-chem 2000 cut gasket DN32 PN16 is the PTFE-class answer for aggressive media — and expanded-PTFE tape (Sealex 14 x 5 mm) for field-formed sealing on damaged faces.
The axes are internal pressure and temperature; the curve divides three regions. Region one (low p, low T): the sheet serves with ordinary assembly practice. Region two: serviceable only with engineering review — controlled bolt load (torque charts), flange condition verified, thinner sheet, sometimes inner eyelets. Region three: choose another material. Two consequences professionals act on: first, steam moves every fibre sheet deep into region two long before the headline temperature — which is why steam mains migrate to graphite or spiral-wound even at modest pressures; second, the diagram assumes correct surface pressure, so an under-torqued joint fails in region one too. For critical joints Klinger's published gasket factors (and EN 13555 data where the design method is EN 1591) complete the calculation; for routine flange work the pT check plus the standard torque table is the working method.
| Flange condition | Sheet thickness | Note |
|---|---|---|
| Good machined faces, standard raised face | 1.5 mm | Default — best blowout and creep behaviour |
| Minor scoring, light corrosion, large diameters | 2.0 mm | The practical plant standard for DN>300 and older flanges |
| Warped or heavily worn faces | 3.0 mm | A repair measure; plan to machine the face instead |
Assembly is half the gasket's performance: faces cleaned to bare metal, gasket dry (no grease on fibre sheet — it destroys the friction the seal depends on), bolts lubricated and pulled in a star pattern to the torque table in stages, and a retorque where the procedure calls for it. Dimensions for cut gaskets follow the flange standard — EN 1092-1 ring dimensions in our PN16 chart and siblings, full-face for flat-face flanges — and the flange finder resolves the pattern when the drawing is missing.
| Recipe class | Klinger grade | Peer-class examples | Equivalence caveat |
|---|---|---|---|
| Aramid/NBR universal | C-4400 | Garlock Blue-Gard 3000 class, Donit and Temac aramid/NBR sheets | Match pT behaviour and approvals line by line |
| Aramid+glass/NBR, steam-capable | C-4430 | Peer high-load aramid grades | Steam capability differs by maker — pT diagrams decide |
| Carbon/NBR high temperature | C-4500 / C-4509 | Peer carbon/NBR grades | Thermal-oil approvals vary |
| Restructured PTFE | top-chem family | Garlock Gylon 3510 class | Filler chemistry (silica, barium sulphate, glass) sets media fit |
| Graphite laminate | Klinger graphite programme | Peer graphite sheets, tanged or foil-reinforced | Oxidation limit in air; reinforcement type matters for handling |
"Equivalent" on a requisition means: same recipe class, pT envelope covering the duty, and the named approvals present (WRAS/KTW drinking water, DVGW gas, BAM oxygen, API/fire test where piping class demands). A cheaper sheet missing the approval is not an equivalent, it is a different product — the same honesty rule as everywhere in our gasket material guide.
Sheet (standard formats 1000 x 1500 and 1500 x 2000 mm, thicknesses 0.5–3 mm) suits workshops that cut their own; cut gaskets to EN 1092-1 or ASME patterns suit everyone else — dimensional consistency, no nesting waste, and traceability printed per gasket. Flange isolation sets (isolation kit guide) and ring-joint or spiral-wound positions ride the same requisition. A quotable line: grade (or recipe class plus approvals if open), dimension (DN/PN or ASME NPS/class, or sheet format), thickness, quantity, and the medium/temperature/pressure so the pT check can be confirmed on our side — we flag lines where the requested grade sits in region two of its diagram rather than quoting blind.
How buying works at cballast. We quote Klinger, Garlock and peer sheet and cut gaskets with the pT sanity check included, approvals stated per line, and standing lists for plants that order by the drawing. Accounts are vetted at onboarding; first order prepaid; established accounts on credit terms with repeat discounts; public bodies and utilities invoiced against purchase order from the first order. RFQs to sales@cballast.com.
Standards and sources referenced: Klinger pT diagrams and grade datasheets (C-4400, C-4430, C-4500, C-4509, C-4324, top-chem); EN 1514-1 (flange gasket dimensions); EN 13555 / EN 1591 (gasket factors and flange calculation); ASME B16.21 (non-metallic flat gaskets); approval schemes WRAS, KTW, DVGW, BAM.
Questions on a grade, a pT check or a cut pattern: write to sales@cballast.com. We answer whether or not you buy from us.