Refrigeration Parts Cross-Reference — Danfoss, Castel, Alco

Reference compiled by cBallast. 8-page PDF; the full content is on this page.
Compiled by
cBallast
Subject
Refrigeration line components
Document type
Reference
Reference
2026 edition
Issued
2026-11-10
Pages
8
Format
Web page and PDF

The brand-to-brand map for refrigeration line components: solenoid valves, filter driers and replaceable cores, sight glasses, thermostatic expansion valves, ball and check valves across Danfoss, Castel, Emerson/Alco and Sporlan/Parker — what legitimately crosses and on which parameters, the connection vocabulary (ODF solder, SAE flare, rotalock) that every cross stands on, the size-code logic of drier shells and cores, and the requisition pattern that lets a mixed-brand plant order everything in one pass without a wrong-connection surprise.

The short version

1. The component-class map

Component classDanfossCastelEmerson / AlcoSporlan / ParkerCross on
Solenoid valvesEVR / EVRH (guide)10x8-series200RB classE-series classCapacity at refrigerant & Δp, connection, NC/NO, pressure rating; coil separately
Filter driers (sealed)DML/DCL (selection guide)DI 4300/4400-class — e.g. DI305E2S (052), DI308E4S (084)ADK / FDB classC-series classSize code (volume+connection), desiccant type (sieve vs sieve/alumina blend), flow direction (uni/bi), pressure class
Drier shells + coresDCR + DM/DC coresShell + core programmeADKS/STAS shells + F-48/H-48 coresShells + RC-type coresCore format (48 cu in standard), core chemistry (drying vs acid/burn-out), shell connection
Sight glassesSGP class3810/3940 classAMI classSA class — e.g. SA-211 1 3/8" solder, SA-213 1 5/8"; generic ODF positions like the 3/8" ODF glassConnection type/size, moisture indicator (yes/no), pressure rating
Thermostatic expansion valvesTE/TGE/TU (finder)—TX / TCL / TI classThe classic TXV programmeRefrigerant, capacity at evap/cond conditions, equalisation (internal/external), charge type, orifice interchangeability within each maker's system
Ball / shut-off valvesGBC class6590-class—Parker programmeConnection, pressure class (high-pressure variants for modern refrigerants), access fitting yes/no
Check valvesNRV class3120-class—Parker programmeOpening Δp, connection, orientation

The table's job is orientation: which maker's family answers which class. The settlement is always numerical — each maker's capacity table at your refrigerant and conditions — which is the work we do per line when quoting a cross, with the basis stated ("crossed from X by capacity at R448A, Δp 0.15 bar").

2. Connections — the vocabulary every cross stands on

ConnectionHow to recognise itWhere it livesTrap
ODF solder (female, brazed)Plain socket; sized by tube OD (3/8", 1/2", 5/8", 7/8"…)Fixed installs, everything in the liquid/suction lineInch tube OD vs millimetre tube on some European plants — 12 mm is not 1/2" (12.7)
SAE flare45° flare nut, unionService work, small systems, replaceable componentsFlare joints loosen under vibration — torque and re-check culture applies
RotalockLarge union nut on a threaded bossCompressor and receiver service valvesRotalock size names by thread (1"-14 etc.) — state the thread, not "big nut"
Metric solderSocket sized 6/10/12/16/22 mmSome European OEM linesThe 12 mm vs 1/2" near-miss again — a vernier settles it in seconds

3. Drier and core logic — the size-code rosetta

Sealed driers: the trade code is volume + connection — first digits give the shell size class (05 = 5 cu in class, 08 = 8, 16 = 16, 30, 41…), the final digit the connection in eighths of an inch (2 = 1/4", 3 = 3/8", 4 = 1/2", 5 = 5/8"); an S suffix convention marks solder. Hence 052, 083, 084, 163, 305 read identically across Danfoss DML, Castel DI, Alco ADK and Sporlan C families, which is what makes the Castel 052-pattern a clean answer to a "DML 052" line. The remaining selection parameters: desiccant (100% molecular sieve for HFC/HFO moisture duty — the pattern in our Castel stock — vs sieve/alumina blends where acid capture after a burn-out matters), flow (uni-directional vs bi-flow for heat pumps), and pressure class (modern high-pressure refrigerants want the 46+ bar class shells). Replaceable-core systems cross on the core format: the 48-cubic-inch core is the market standard — Alco F-48 (drying) and H-48 (high-capacity/clean-up class) fit the corresponding shells, and suction-line clean-up after a compressor failure is core-and-shell territory, not sealed-drier territory. Full family selection logic lives in the filter drier guide.

4. What crosses, what does not — the honesty table

SituationVerdictWhy
Sealed drier, same size code, same desiccant class, same pressure classCrosses cleanlyThe code system is shared trade language
Sight glass, same connection and ratingCrosses cleanlyIndicator chemistry differs cosmetically (colour scale), function identical
Solenoid valve by capacity tableCrosses with stated basisNominal size names diverge across brands — only the table settles it; coil ordered per the new body's maker
TXV across brandsCrosses with engineering careRefrigerant, charge type, equalisation and capacity must all match; orifice assemblies do NOT interchange between makers' bodies
Coils between brandsDoes not crossEvery maker's coil fits its own armature system — Danfoss 018F on Danfoss, Castel 9100-class on Castel, Alco cable sets on Alco
Electronic expansion valves + drivers/controllersDoes not cross casuallyValve, driver and control algorithm are a system — see the EKC/AK-CC guide for the Danfoss side
Standard component offered on a high-pressure refrigerant dutyDoes not crossPressure class is a safety rating, not a preference — the modern refrigerant transitions (R404A to R448A/449A guide) made this the live trap
Anything inside an OEM warranty or classed installationOEM pattern, statedSame rule as everywhere in our catalogue — the paper governs

5. The mixed-brand requisition — one pass, no surprises

The pattern that works, line by line: component class + the number on the part (any brand's — we translate), connection measured (type + size, vernier beats memory), refrigerant and duty (the pressure-class and desiccant decisions hang on it), and function flags (NC/NO, bi-flow, indicator, equalisation). Photos of stampings close the gaps. What comes back is a quote where every crossed line names its basis and every kept-OEM line says why — the same discipline as our IMPA/OEM refrigeration cross-reference applies at the brand level. Plant engineers standardising a spares drawer get the inverse service: send the installed base list and we return the minimum stock set (coils by voltage, driers by size code, one sight glass per line size, service kits per the EVR guide) that covers it across brands.

How buying works at cballast. We stock Danfoss, Castel, Alco/Emerson and Sporlan-class line components side by side, cross by capacity table with the basis stated per line, and keep the connection vocabulary honest (ODF/flare/rotalock/metric measured, never assumed). Accounts are vetted at onboarding; first order prepaid; established accounts on credit terms with repeat discounts; public bodies and utilities invoiced against purchase order from the first order. RFQs to sales@cballast.com.

Frequently asked questions

Is there a Castel equivalent to a Danfoss filter drier?
Yes — sealed driers cross cleanly on the shared size-code system (052/083/084…), desiccant class and pressure rating. A Danfoss DML 083 line is answered by the Castel DI 083-pattern with 100% molecular sieve at the same connection, stated as a cross on the quote.
What does the 083 or 084 on a filter drier mean?
Shell volume class plus connection size in eighths of an inch: 08 = 8 cubic inch shell, 3 = 3/8" connections, 4 = 1/2". The convention is shared across Danfoss, Castel, Alco and Sporlan families, which is exactly why driers are the easiest refrigeration cross there is.
Can I replace an Alco solenoid valve with a Danfoss EVR?
Usually, by capacity: match the duty (NC/NO), the capacity at your refrigerant and pressure drop from the tables (not the size names), the connection, and the pressure rating — then order the Danfoss coil for the supply voltage, because coils never cross between brands. We state the basis per line when we quote such a swap.
Do TXV orifices interchange between brands?
No. Interchangeable-orifice systems work within one maker's body system only. Across brands you cross the complete valve — refrigerant, capacity, charge type and equalisation all matched. Within a brand, the orifice/body logic is what makes stocking efficient.
What is the difference between an F-48 and H-48 drier core?
Both are the standard 48-cubic-inch core format; they differ in chemistry/purpose — the F-class is the standard drying core, the H-class the high-capacity/clean-up oriented one used in suction-line filtration and after burn-outs. Shells accept either; the duty picks the core.
Why does the pressure class suddenly matter on these small parts?
Because the refrigerant transitions pushed working pressures up: components rated for the R404A era are not automatically right for R448A/R449A retrofits and are wrong for R410A-class pressures. Every maker sells high-pressure variants; the cross must stay inside the rating, which is why we ask for the refrigerant on every line.
Who supplies mixed-brand refrigeration components in Europe?
cballast.com stocks and quotes Danfoss, Castel, Alco/Emerson and Sporlan-class solenoids, driers, cores, sight glasses and valves on one quotation, crossed by capacity with the basis stated. Write to sales@cballast.com with part numbers or stamping photos.

References and related guides

Standards and sources referenced: Danfoss, Castel, Emerson/Alco and Sporlan/Parker catalogue data and capacity tables; EN 378 pressure-class context for refrigerant transitions; the shared trade size-code conventions for driers and line components.

Questions on a cross you are unsure of or a part you cannot identify: write to sales@cballast.com. We answer whether or not you buy from us.

Open / Download PDF

Compiled by cBallast for identification and cross-reference. Part numbers, designations and trademarks belong to their respective manufacturers. Confirm ratings and dimensions against the manufacturer's current documentation and the nameplate of the installed equipment before ordering or installation.